Effect of ClO2 on the distribution of Legionella pneumophila serogroups in a Teaching Hospital
Abstract The prevention of Legionella colonization of water systems is one of the goals of hospital management. Among chemical disinfection methods, chlorine dioxide (ClO2) has been largely used to control Legionella in water systems. We analysed the distribution of Legionella pneumophila serogroups...
Saved in:
Published in: | European journal of public health 2020-09, Vol.30 (Supplement_5) |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract
The prevention of Legionella colonization of water systems is one of the goals of hospital management. Among chemical disinfection methods, chlorine dioxide (ClO2) has been largely used to control Legionella in water systems. We analysed the distribution of Legionella pneumophila serogroups (sg) and Legionella other spp before (PRE) and after (POST) installation of chlorine dioxide (ClO2) continuous disinfection systems in a Teaching Hospital in Rome.
According to the Italian National Guidelines, our surveillance plan involved a systematic sampling of the water system. The sampling was performed from Jan. 2010 to Dec. 2019. From 2011 to 2019, ClO2 continuous disinfection systems were installed in all hot water system of the hospital, and maintained at a concentration of 0.25 mg/l at the end point. The isolated strains of Legionella were first serotyped using a kit that identifies sg1, other species and that discriminate sg from 2 to 15.
1505 hot water samples were collected from the Hospital and analysed. 363 samples are PRE and 1142 are POST activation of ClO2. Only the 16.74% of monitored sampling points were colonized by Legionella during the study period. This percentage decrease from 31.40% of PRE samples, to 12.08% of POST samples (p ≤ 0.000). The sg isolated were: sg3 (60.31%), sg8 (17.12%), sg1 (16.73%), sg6 (1.95%) and other species (3.89%). Comparing the distribution of sg between the PRE and POST samples, the sg8 showed a high increase (+136.84%) and the sg3 a slight decrease (-17.94%). These variations were statistically significative.
The results showed a predominance of Legionella pneumophila sg3, compared to what was observed in a multicenter study conducted between different hospitals of various regions of Italy, where sg6 was the major isolate. The ClO2 affect the distribution of sg, in particular for sg8. This interesting result will be further investigated.
Key messages
Our data deriving from an environmental monitoring plan, show that the ClO2 affects the distribution of Legionella’s serogroups. The ClO2 reduces the percentage of samples colonized by Legionella.
The ClO2 reduces the percentage of samples colonized by Legionella. |
---|---|