Calculating Digital Electric Drive Control Systems with a Finite Time of Free Process Attenuation

The calculation of a digital regulator intended to ensure the full attenuation of free processes in a linear regulation system for a finite number of quantization periods is considered. It is shown that the full attenuation of a free process cannot be achieved for a number of sampling periods smalle...

Full description

Saved in:
Bibliographic Details
Published in:Russian electrical engineering 2020-12, Vol.91 (12), p.767-771
Main Author: Korshunov, A. I.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 771
container_issue 12
container_start_page 767
container_title Russian electrical engineering
container_volume 91
creator Korshunov, A. I.
description The calculation of a digital regulator intended to ensure the full attenuation of free processes in a linear regulation system for a finite number of quantization periods is considered. It is shown that the full attenuation of a free process cannot be achieved for a number of sampling periods smaller than the order of the continuous part of the system. The digital regulator of the system of stabilizing the dc engine rotation frequency, an example of calculating which is discussed in this article, allows trying out a continuous setting action for two time sampling periods at the operation in the linear zone.
doi_str_mv 10.3103/S1068371220120093
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2499987346</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2499987346</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1833-fa5ab7833b6b46be15c1989e857e5b21236eeb43f5c993520eec159b558fb9d03</originalsourceid><addsrcrecordid>eNp1kEtLAzEUhYMoWKs_wF3A9Wgek5nJskwfCgWF1vWQxDs1ZTqpSUbpvzelggtxdQ-c75wLB6FbSu45JfxhRUlR8ZIyRigjRPIzNKKS51lFKDlPOtnZ0b9EVyFsCREFy_MRUrXqzNCpaPsNntqNjarDsw5M9NbgqbefgGvXR-86vDqECLuAv2x8xwrPbW8j4LXdAXYtnnsA_OKdgRDwJEboh9Tq-mt00aouwM3PHaPX-WxdP2bL58VTPVlmhlacZ60SSpdJ6ULnhQYqDJWVhEqUIDSjjBcAOuetMFJywQiAoUJqIapWyzfCx-ju1Lv37mOAEJutG3yfXjYsl1JWJc-LRNETZbwLwUPb7L3dKX9oKGmOSzZ_lkwZdsqExPYb8L_N_4e-Ab_HdGY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2499987346</pqid></control><display><type>article</type><title>Calculating Digital Electric Drive Control Systems with a Finite Time of Free Process Attenuation</title><source>Springer Link</source><creator>Korshunov, A. I.</creator><creatorcontrib>Korshunov, A. I.</creatorcontrib><description>The calculation of a digital regulator intended to ensure the full attenuation of free processes in a linear regulation system for a finite number of quantization periods is considered. It is shown that the full attenuation of a free process cannot be achieved for a number of sampling periods smaller than the order of the continuous part of the system. The digital regulator of the system of stabilizing the dc engine rotation frequency, an example of calculating which is discussed in this article, allows trying out a continuous setting action for two time sampling periods at the operation in the linear zone.</description><identifier>ISSN: 1068-3712</identifier><identifier>EISSN: 1934-8010</identifier><identifier>DOI: 10.3103/S1068371220120093</identifier><language>eng</language><publisher>Moscow: Pleiades Publishing</publisher><subject>Attenuation ; Electric drives ; Engineering ; Machines ; Manufacturing ; Mathematical analysis ; Processes ; Sampling</subject><ispartof>Russian electrical engineering, 2020-12, Vol.91 (12), p.767-771</ispartof><rights>Allerton Press, Inc. 2020. ISSN 1068-3712, Russian Electrical Engineering, 2020, Vol. 91, No. 12, pp. 767–771. © Allerton Press, Inc., 2020. Russian Text © The Author(s), 2020, published in Elektrotekhnika, 2020, No. 12, pp. 44–48.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Korshunov, A. I.</creatorcontrib><title>Calculating Digital Electric Drive Control Systems with a Finite Time of Free Process Attenuation</title><title>Russian electrical engineering</title><addtitle>Russ. Electr. Engin</addtitle><description>The calculation of a digital regulator intended to ensure the full attenuation of free processes in a linear regulation system for a finite number of quantization periods is considered. It is shown that the full attenuation of a free process cannot be achieved for a number of sampling periods smaller than the order of the continuous part of the system. The digital regulator of the system of stabilizing the dc engine rotation frequency, an example of calculating which is discussed in this article, allows trying out a continuous setting action for two time sampling periods at the operation in the linear zone.</description><subject>Attenuation</subject><subject>Electric drives</subject><subject>Engineering</subject><subject>Machines</subject><subject>Manufacturing</subject><subject>Mathematical analysis</subject><subject>Processes</subject><subject>Sampling</subject><issn>1068-3712</issn><issn>1934-8010</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp1kEtLAzEUhYMoWKs_wF3A9Wgek5nJskwfCgWF1vWQxDs1ZTqpSUbpvzelggtxdQ-c75wLB6FbSu45JfxhRUlR8ZIyRigjRPIzNKKS51lFKDlPOtnZ0b9EVyFsCREFy_MRUrXqzNCpaPsNntqNjarDsw5M9NbgqbefgGvXR-86vDqECLuAv2x8xwrPbW8j4LXdAXYtnnsA_OKdgRDwJEboh9Tq-mt00aouwM3PHaPX-WxdP2bL58VTPVlmhlacZ60SSpdJ6ULnhQYqDJWVhEqUIDSjjBcAOuetMFJywQiAoUJqIapWyzfCx-ju1Lv37mOAEJutG3yfXjYsl1JWJc-LRNETZbwLwUPb7L3dKX9oKGmOSzZ_lkwZdsqExPYb8L_N_4e-Ab_HdGY</recordid><startdate>20201201</startdate><enddate>20201201</enddate><creator>Korshunov, A. I.</creator><general>Pleiades Publishing</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20201201</creationdate><title>Calculating Digital Electric Drive Control Systems with a Finite Time of Free Process Attenuation</title><author>Korshunov, A. I.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1833-fa5ab7833b6b46be15c1989e857e5b21236eeb43f5c993520eec159b558fb9d03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Attenuation</topic><topic>Electric drives</topic><topic>Engineering</topic><topic>Machines</topic><topic>Manufacturing</topic><topic>Mathematical analysis</topic><topic>Processes</topic><topic>Sampling</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Korshunov, A. I.</creatorcontrib><collection>CrossRef</collection><jtitle>Russian electrical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Korshunov, A. I.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Calculating Digital Electric Drive Control Systems with a Finite Time of Free Process Attenuation</atitle><jtitle>Russian electrical engineering</jtitle><stitle>Russ. Electr. Engin</stitle><date>2020-12-01</date><risdate>2020</risdate><volume>91</volume><issue>12</issue><spage>767</spage><epage>771</epage><pages>767-771</pages><issn>1068-3712</issn><eissn>1934-8010</eissn><abstract>The calculation of a digital regulator intended to ensure the full attenuation of free processes in a linear regulation system for a finite number of quantization periods is considered. It is shown that the full attenuation of a free process cannot be achieved for a number of sampling periods smaller than the order of the continuous part of the system. The digital regulator of the system of stabilizing the dc engine rotation frequency, an example of calculating which is discussed in this article, allows trying out a continuous setting action for two time sampling periods at the operation in the linear zone.</abstract><cop>Moscow</cop><pub>Pleiades Publishing</pub><doi>10.3103/S1068371220120093</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1068-3712
ispartof Russian electrical engineering, 2020-12, Vol.91 (12), p.767-771
issn 1068-3712
1934-8010
language eng
recordid cdi_proquest_journals_2499987346
source Springer Link
subjects Attenuation
Electric drives
Engineering
Machines
Manufacturing
Mathematical analysis
Processes
Sampling
title Calculating Digital Electric Drive Control Systems with a Finite Time of Free Process Attenuation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A02%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Calculating%20Digital%20Electric%20Drive%20Control%20Systems%20with%20a%20Finite%20Time%20of%20Free%20Process%20Attenuation&rft.jtitle=Russian%20electrical%20engineering&rft.au=Korshunov,%20A.%20I.&rft.date=2020-12-01&rft.volume=91&rft.issue=12&rft.spage=767&rft.epage=771&rft.pages=767-771&rft.issn=1068-3712&rft.eissn=1934-8010&rft_id=info:doi/10.3103/S1068371220120093&rft_dat=%3Cproquest_cross%3E2499987346%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1833-fa5ab7833b6b46be15c1989e857e5b21236eeb43f5c993520eec159b558fb9d03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2499987346&rft_id=info:pmid/&rfr_iscdi=true