Loading…
Quality control of cytostatic drug preparations—comparison of workflow and performance of Raman/UV and high-performance liquid chromatography coupled with diode array detection (HPLC-DAD)
The drugs used for treatment during chemotherapy are manufactured individually for each patient in specialised pharmacies. Thorough quality control to confirm the identity of the delivered active pharmaceutical ingredient and the final concentration of the prepared application solution is not standa...
Saved in:
Published in: | Analytical and bioanalytical chemistry 2021-04, Vol.413 (9), p.2587-2596 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The drugs used for treatment during chemotherapy are manufactured individually for each patient in specialised pharmacies. Thorough quality control to confirm the identity of the delivered active pharmaceutical ingredient and the final concentration of the prepared application solution is not standardized yet except for optical or gravimetric testing. However, solution stability problems, counterfeit drugs, and erroneous or deliberate underdosage may occur and negatively influence the quality of the product and could cause severe health risks for the patient. To take a step towards analytical quality control, an on-site analytical instrument using Raman and UV absorption spectroscopy was employed and the results were compared to high-performance liquid chromatography coupled to diode array detection. Within the scope of the technology evaluation, the uncertainty of measurement was determined for the analysis of the five frequently used cytostatic drugs 5-fluorouracil, cyclophosphamide, gemcitabine, irinotecan and paclitaxel. The Raman/UV technique (2.0–3.2% uncertainty of measurement; level of confidence: 95%) achieves a combined uncertainty of measurement comparable to HPLC-DAD (1.7–3.2% uncertainty of measurement; level of confidence: 95%) for the substances 5-fluorouracil, cyclophosphamide and gemcitabine. However, the uncertainty of measurement for the substances irinotecan and paclitaxel is three times higher when the Raman/UV technique is used. This is due to the fact that the Raman/UV technique analyses the undiluted sample; therefore, the sample has a higher viscosity and tendency to foam. Out of 136 patient-specific preparations analysed within this study, 96% had a deviation of less than 10% from the target content.
Graphical abstract |
---|---|
ISSN: | 1618-2642 1618-2650 |
DOI: | 10.1007/s00216-021-03223-9 |