Loading…
Accuracy and Stability for Optimum Performance of Digital Fringe Profilometry Method
Various method was developed for the acquisition of the three-dimensional surface of an object. One of the more popular methods used is the structured light profilometry method. It can capture a high-resolution three-dimensional object in real-time. Not only that, but this method is also non-invasiv...
Saved in:
Published in: | Journal of physics. Conference series 2021-02, Vol.1755 (1), p.12018 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c1958-dd491ffcd628aa0383a7a2d0aa3a643f07e18696bd0998d4a6b52c747442ca6c3 |
container_end_page | |
container_issue | 1 |
container_start_page | 12018 |
container_title | Journal of physics. Conference series |
container_volume | 1755 |
creator | Chua, Shanyu Chin Lim, Chee Kheng Eng, Swee Tai Loh, Chiun Fook Chong, Yen |
description | Various method was developed for the acquisition of the three-dimensional surface of an object. One of the more popular methods used is the structured light profilometry method. It can capture a high-resolution three-dimensional object in real-time. Not only that, but this method is also non-invasive, which is very suitable for the measurement of fragile samples. This paper discusses the accuracy and stability of a structured light profilometry method that is used to obtain a 3D measurement. The experiment is done by using a calibrated camera and projector. A light pattern is then projected onto the sample and captured by the camera. The accuracy of the system is investigated by capturing a flat plate with an increment of 50 µm from 0 µm to 1000 µm. The result has shown a maximum percentage error of this system is 15.76% which is 9.3511 µm, and the minimum percentage error is 0.15% which is 0.7339 µm. For the stability test, the plate was captured thirty times at the same location, and the data obtained shows the consistency of the system has a minimum and maximum standard deviation of 2.4991 µm and 6.8886 µm, which is within 7 µm. The test on the feeler gauge shows a maximum percentage error of 2.12% which is 2.1671 µm. |
doi_str_mv | 10.1088/1742-6596/1755/1/012018 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2512943463</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2512943463</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1958-dd491ffcd628aa0383a7a2d0aa3a643f07e18696bd0998d4a6b52c747442ca6c3</originalsourceid><addsrcrecordid>eNo9kFtLw0AQhRdRsFZ_gws-1-4tm81jqVaFSgvW52W6l7olydZN8pB_b0Kl83LOMIc58CH0SMkzJUrNaS7YTGaFHFyWzemcUEaoukKTy-X64pW6RXdNcySED5NP0G5hTJfA9Bhqi79a2IcytD32MeHNqQ1VV-GtS8NaQW0cjh6_hENoocSrFOqDw9sUfShj5drU40_X_kR7j248lI17-Ncp-l697pbvs_Xm7WO5WM8MLTI1s1YU1HtjJVMAhCsOOTBLADhIwT3JHVWykHtLikJZAXKfMZOLXAhmQBo-RU_nv6cUfzvXtPoYu1QPlZpllBWCC8mHVH5OmRSbJjmvTylUkHpNiR4R6hGOHkHpEaGm-oyQ_wGd42Q-</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2512943463</pqid></control><display><type>article</type><title>Accuracy and Stability for Optimum Performance of Digital Fringe Profilometry Method</title><source>Publicly Available Content Database</source><source>Full-Text Journals in Chemistry (Open access)</source><creator>Chua, Shanyu ; Chin Lim, Chee ; Kheng Eng, Swee ; Tai Loh, Chiun ; Fook Chong, Yen</creator><creatorcontrib>Chua, Shanyu ; Chin Lim, Chee ; Kheng Eng, Swee ; Tai Loh, Chiun ; Fook Chong, Yen</creatorcontrib><description>Various method was developed for the acquisition of the three-dimensional surface of an object. One of the more popular methods used is the structured light profilometry method. It can capture a high-resolution three-dimensional object in real-time. Not only that, but this method is also non-invasive, which is very suitable for the measurement of fragile samples. This paper discusses the accuracy and stability of a structured light profilometry method that is used to obtain a 3D measurement. The experiment is done by using a calibrated camera and projector. A light pattern is then projected onto the sample and captured by the camera. The accuracy of the system is investigated by capturing a flat plate with an increment of 50 µm from 0 µm to 1000 µm. The result has shown a maximum percentage error of this system is 15.76% which is 9.3511 µm, and the minimum percentage error is 0.15% which is 0.7339 µm. For the stability test, the plate was captured thirty times at the same location, and the data obtained shows the consistency of the system has a minimum and maximum standard deviation of 2.4991 µm and 6.8886 µm, which is within 7 µm. The test on the feeler gauge shows a maximum percentage error of 2.12% which is 2.1671 µm.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/1755/1/012018</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Accuracy ; Cameras ; Errors ; Flat plates ; Physics ; Stability tests ; Structural stability</subject><ispartof>Journal of physics. Conference series, 2021-02, Vol.1755 (1), p.12018</ispartof><rights>2021. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1958-dd491ffcd628aa0383a7a2d0aa3a643f07e18696bd0998d4a6b52c747442ca6c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2512943463?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,777,781,25734,27905,27906,36993,44571</link.rule.ids></links><search><creatorcontrib>Chua, Shanyu</creatorcontrib><creatorcontrib>Chin Lim, Chee</creatorcontrib><creatorcontrib>Kheng Eng, Swee</creatorcontrib><creatorcontrib>Tai Loh, Chiun</creatorcontrib><creatorcontrib>Fook Chong, Yen</creatorcontrib><title>Accuracy and Stability for Optimum Performance of Digital Fringe Profilometry Method</title><title>Journal of physics. Conference series</title><description>Various method was developed for the acquisition of the three-dimensional surface of an object. One of the more popular methods used is the structured light profilometry method. It can capture a high-resolution three-dimensional object in real-time. Not only that, but this method is also non-invasive, which is very suitable for the measurement of fragile samples. This paper discusses the accuracy and stability of a structured light profilometry method that is used to obtain a 3D measurement. The experiment is done by using a calibrated camera and projector. A light pattern is then projected onto the sample and captured by the camera. The accuracy of the system is investigated by capturing a flat plate with an increment of 50 µm from 0 µm to 1000 µm. The result has shown a maximum percentage error of this system is 15.76% which is 9.3511 µm, and the minimum percentage error is 0.15% which is 0.7339 µm. For the stability test, the plate was captured thirty times at the same location, and the data obtained shows the consistency of the system has a minimum and maximum standard deviation of 2.4991 µm and 6.8886 µm, which is within 7 µm. The test on the feeler gauge shows a maximum percentage error of 2.12% which is 2.1671 µm.</description><subject>Accuracy</subject><subject>Cameras</subject><subject>Errors</subject><subject>Flat plates</subject><subject>Physics</subject><subject>Stability tests</subject><subject>Structural stability</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNo9kFtLw0AQhRdRsFZ_gws-1-4tm81jqVaFSgvW52W6l7olydZN8pB_b0Kl83LOMIc58CH0SMkzJUrNaS7YTGaFHFyWzemcUEaoukKTy-X64pW6RXdNcySED5NP0G5hTJfA9Bhqi79a2IcytD32MeHNqQ1VV-GtS8NaQW0cjh6_hENoocSrFOqDw9sUfShj5drU40_X_kR7j248lI17-Ncp-l697pbvs_Xm7WO5WM8MLTI1s1YU1HtjJVMAhCsOOTBLADhIwT3JHVWykHtLikJZAXKfMZOLXAhmQBo-RU_nv6cUfzvXtPoYu1QPlZpllBWCC8mHVH5OmRSbJjmvTylUkHpNiR4R6hGOHkHpEaGm-oyQ_wGd42Q-</recordid><startdate>20210201</startdate><enddate>20210201</enddate><creator>Chua, Shanyu</creator><creator>Chin Lim, Chee</creator><creator>Kheng Eng, Swee</creator><creator>Tai Loh, Chiun</creator><creator>Fook Chong, Yen</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20210201</creationdate><title>Accuracy and Stability for Optimum Performance of Digital Fringe Profilometry Method</title><author>Chua, Shanyu ; Chin Lim, Chee ; Kheng Eng, Swee ; Tai Loh, Chiun ; Fook Chong, Yen</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1958-dd491ffcd628aa0383a7a2d0aa3a643f07e18696bd0998d4a6b52c747442ca6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Accuracy</topic><topic>Cameras</topic><topic>Errors</topic><topic>Flat plates</topic><topic>Physics</topic><topic>Stability tests</topic><topic>Structural stability</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chua, Shanyu</creatorcontrib><creatorcontrib>Chin Lim, Chee</creatorcontrib><creatorcontrib>Kheng Eng, Swee</creatorcontrib><creatorcontrib>Tai Loh, Chiun</creatorcontrib><creatorcontrib>Fook Chong, Yen</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chua, Shanyu</au><au>Chin Lim, Chee</au><au>Kheng Eng, Swee</au><au>Tai Loh, Chiun</au><au>Fook Chong, Yen</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy and Stability for Optimum Performance of Digital Fringe Profilometry Method</atitle><jtitle>Journal of physics. Conference series</jtitle><date>2021-02-01</date><risdate>2021</risdate><volume>1755</volume><issue>1</issue><spage>12018</spage><pages>12018-</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>Various method was developed for the acquisition of the three-dimensional surface of an object. One of the more popular methods used is the structured light profilometry method. It can capture a high-resolution three-dimensional object in real-time. Not only that, but this method is also non-invasive, which is very suitable for the measurement of fragile samples. This paper discusses the accuracy and stability of a structured light profilometry method that is used to obtain a 3D measurement. The experiment is done by using a calibrated camera and projector. A light pattern is then projected onto the sample and captured by the camera. The accuracy of the system is investigated by capturing a flat plate with an increment of 50 µm from 0 µm to 1000 µm. The result has shown a maximum percentage error of this system is 15.76% which is 9.3511 µm, and the minimum percentage error is 0.15% which is 0.7339 µm. For the stability test, the plate was captured thirty times at the same location, and the data obtained shows the consistency of the system has a minimum and maximum standard deviation of 2.4991 µm and 6.8886 µm, which is within 7 µm. The test on the feeler gauge shows a maximum percentage error of 2.12% which is 2.1671 µm.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/1755/1/012018</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-6588 |
ispartof | Journal of physics. Conference series, 2021-02, Vol.1755 (1), p.12018 |
issn | 1742-6588 1742-6596 |
language | eng |
recordid | cdi_proquest_journals_2512943463 |
source | Publicly Available Content Database; Full-Text Journals in Chemistry (Open access) |
subjects | Accuracy Cameras Errors Flat plates Physics Stability tests Structural stability |
title | Accuracy and Stability for Optimum Performance of Digital Fringe Profilometry Method |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-20T14%3A15%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20and%20Stability%20for%20Optimum%20Performance%20of%20Digital%20Fringe%20Profilometry%20Method&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Chua,%20Shanyu&rft.date=2021-02-01&rft.volume=1755&rft.issue=1&rft.spage=12018&rft.pages=12018-&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/1755/1/012018&rft_dat=%3Cproquest_cross%3E2512943463%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1958-dd491ffcd628aa0383a7a2d0aa3a643f07e18696bd0998d4a6b52c747442ca6c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2512943463&rft_id=info:pmid/&rfr_iscdi=true |