Risk analysis in terms of implementation of large scale cogeneration power plant
The introduction of large-scale technology carries a number of risks. This paper presents the risks associated with the introduction of a system for combined production of electricity and thermal energy (CHP) through direct combustion of biomass. It is envisaged that the residual amount of heat ener...
Saved in:
Published in: | IOP conference series. Materials Science and Engineering 2021-01, Vol.1031 (1), p.12081 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The introduction of large-scale technology carries a number of risks. This paper presents the risks associated with the introduction of a system for combined production of electricity and thermal energy (CHP) through direct combustion of biomass. It is envisaged that the residual amount of heat energy will be converted into electricity through the use of an ORC module. All possible risks have been identified based on the technology specifics, and the possible consequences of the risk have been indicated. A risk matrix has been prepared for both site and technology specifics in order to identify the type of risk. Based on the outputs, a proposal for reducing the risk has been made. |
---|---|
ISSN: | 1757-8981 1757-899X |
DOI: | 10.1088/1757-899X/1031/1/012081 |