Voltage Sensor Based on a Plastic Optical Fiber with a Rectangular Hole
In this paper, we present an AC voltage sensor based on a plastic optical fiber (POF) with a rectangular hole filled with a polymer-dispersed liquid crystal (PDLC) film. The dimensions of the rectangular hole and PDLC film used in the experiment were approximately 2 × 0.65 mm2 and 20 × 0.6 × 0.2 mm3...
Saved in:
Published in: | Sensors and materials 2021-04, Vol.33 (4), p.1405 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this paper, we present an AC voltage sensor based on a plastic optical fiber (POF) with a rectangular hole filled with a polymer-dispersed liquid crystal (PDLC) film. The dimensions of the rectangular hole and PDLC film used in the experiment were approximately 2 × 0.65 mm2 and 20 × 0.6 × 0.2 mm3, respectively. The root-mean-square (RMS) amplitude of AC voltage at 60 Hz from 0 to 80 V was measured using this sensor. The transmittance of this sensor was a nonlinear function of the applied voltage. In the approximate linear region from 8 to 23 V, the sensitivity of this sensor was approximately 0.017 V−1. The results show that the proposed voltage sensor can be used to measure the RMS amplitude of AC voltage. |
---|---|
ISSN: | 0914-4935 2435-0869 |
DOI: | 10.18494/SAM.2021.3259 |