Voltage Sensor Based on a Plastic Optical Fiber with a Rectangular Hole

In this paper, we present an AC voltage sensor based on a plastic optical fiber (POF) with a rectangular hole filled with a polymer-dispersed liquid crystal (PDLC) film. The dimensions of the rectangular hole and PDLC film used in the experiment were approximately 2 × 0.65 mm2 and 20 × 0.6 × 0.2 mm3...

Full description

Saved in:
Bibliographic Details
Published in:Sensors and materials 2021-04, Vol.33 (4), p.1405
Main Authors: Seo, Hyejin, Prabowo, Jonathan, Park, Jaehee
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this paper, we present an AC voltage sensor based on a plastic optical fiber (POF) with a rectangular hole filled with a polymer-dispersed liquid crystal (PDLC) film. The dimensions of the rectangular hole and PDLC film used in the experiment were approximately 2 × 0.65 mm2 and 20 × 0.6 × 0.2 mm3, respectively. The root-mean-square (RMS) amplitude of AC voltage at 60 Hz from 0 to 80 V was measured using this sensor. The transmittance of this sensor was a nonlinear function of the applied voltage. In the approximate linear region from 8 to 23 V, the sensitivity of this sensor was approximately 0.017 V−1. The results show that the proposed voltage sensor can be used to measure the RMS amplitude of AC voltage.
ISSN:0914-4935
2435-0869
DOI:10.18494/SAM.2021.3259