Loading…

Performance evaluation of dynamic pulley damper system for installation angle

Dynamic pulley damper system (DPDS) as an innovative methodology for a response control system using a block and tackle mechanism to provide enhanced vibration reduction in high-rise buildings, has been proposed. The key aspect of this system is to exponentially increase the damper movement using an...

Full description

Saved in:
Bibliographic Details
Published in:IOP conference series. Earth and environmental science 2021-04, Vol.708 (1), p.12001
Main Authors: Majima, R, Hayashi, K, Saito, T
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 1
container_start_page 12001
container_title IOP conference series. Earth and environmental science
container_volume 708
creator Majima, R
Hayashi, K
Saito, T
description Dynamic pulley damper system (DPDS) as an innovative methodology for a response control system using a block and tackle mechanism to provide enhanced vibration reduction in high-rise buildings, has been proposed. The key aspect of this system is to exponentially increase the damper movement using an amplification mechanism comprising movable pulleys and a wire. This paper presents the relation between the arrangement of the wire’s angles, particularly in the amplification part, and the vibration reduction effect. The DPDS is introduced into a center-core high-rise building. Two small building varieties with different core heights are designed; then, a wire is stretched between the frame and the core structures. The capability of the DPDS to control vibration is confirmed via the shaking table test. Additionally, the accuracy of the simulation models is verified by a comparison with the experimental results. Moreover, this paper includes a parametric analysis test to determine the wire-stretching angle for establishing the most efficient design. The results of the above analysis show that the wire-stretching angle influences the seismic performance of the DPDS.
doi_str_mv 10.1088/1755-1315/708/1/012001
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2518771195</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2518771195</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1931-90da7e91c04de30e73bb0f96e2ec40be1e3888f460fa2b060ccb85c3d949d5433</originalsourceid><addsrcrecordid>eNo9kEtLxDAQx4MouK5-BQl4rp1p2qY5yuILVvSg55CmE-nSl0kr9NvbpbKnmWH-D_gxdotwj1AUMcosi1BgFktYrhgwAcAztjk9zk87yEt2FcIBIJepUBv29kHe9b41nSVOv6aZzFj3He8dr-bOtLXlw9Q0NPPKtAN5HuYwUssXD6-7MJqmWQ2m-27oml040wS6-Z9b9vX0-Ll7ifbvz6-7h31kUQmMFFRGkkILaUUCSIqyBKdySsimUBKSKIrCpTk4k5SQg7VlkVlRqVRVWSrElt2tuYPvfyYKoz70k--WSp1kWEiJqLJFla8q6_sQPDk9-Lo1ftYI-ohOH6noIyG9oNOoV3TiD3oJYhM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2518771195</pqid></control><display><type>article</type><title>Performance evaluation of dynamic pulley damper system for installation angle</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><creator>Majima, R ; Hayashi, K ; Saito, T</creator><creatorcontrib>Majima, R ; Hayashi, K ; Saito, T</creatorcontrib><description>Dynamic pulley damper system (DPDS) as an innovative methodology for a response control system using a block and tackle mechanism to provide enhanced vibration reduction in high-rise buildings, has been proposed. The key aspect of this system is to exponentially increase the damper movement using an amplification mechanism comprising movable pulleys and a wire. This paper presents the relation between the arrangement of the wire’s angles, particularly in the amplification part, and the vibration reduction effect. The DPDS is introduced into a center-core high-rise building. Two small building varieties with different core heights are designed; then, a wire is stretched between the frame and the core structures. The capability of the DPDS to control vibration is confirmed via the shaking table test. Additionally, the accuracy of the simulation models is verified by a comparison with the experimental results. Moreover, this paper includes a parametric analysis test to determine the wire-stretching angle for establishing the most efficient design. The results of the above analysis show that the wire-stretching angle influences the seismic performance of the DPDS.</description><identifier>ISSN: 1755-1307</identifier><identifier>EISSN: 1755-1315</identifier><identifier>DOI: 10.1088/1755-1315/708/1/012001</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Amplification ; Buildings ; Control systems ; High rise buildings ; Model accuracy ; Parametric analysis ; Performance evaluation ; Pulleys ; Seismic activity ; Seismic response ; Shake table tests ; Stretching ; Vibration ; Vibration control ; Wire</subject><ispartof>IOP conference series. Earth and environmental science, 2021-04, Vol.708 (1), p.12001</ispartof><rights>2021. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2518771195?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Majima, R</creatorcontrib><creatorcontrib>Hayashi, K</creatorcontrib><creatorcontrib>Saito, T</creatorcontrib><title>Performance evaluation of dynamic pulley damper system for installation angle</title><title>IOP conference series. Earth and environmental science</title><description>Dynamic pulley damper system (DPDS) as an innovative methodology for a response control system using a block and tackle mechanism to provide enhanced vibration reduction in high-rise buildings, has been proposed. The key aspect of this system is to exponentially increase the damper movement using an amplification mechanism comprising movable pulleys and a wire. This paper presents the relation between the arrangement of the wire’s angles, particularly in the amplification part, and the vibration reduction effect. The DPDS is introduced into a center-core high-rise building. Two small building varieties with different core heights are designed; then, a wire is stretched between the frame and the core structures. The capability of the DPDS to control vibration is confirmed via the shaking table test. Additionally, the accuracy of the simulation models is verified by a comparison with the experimental results. Moreover, this paper includes a parametric analysis test to determine the wire-stretching angle for establishing the most efficient design. The results of the above analysis show that the wire-stretching angle influences the seismic performance of the DPDS.</description><subject>Amplification</subject><subject>Buildings</subject><subject>Control systems</subject><subject>High rise buildings</subject><subject>Model accuracy</subject><subject>Parametric analysis</subject><subject>Performance evaluation</subject><subject>Pulleys</subject><subject>Seismic activity</subject><subject>Seismic response</subject><subject>Shake table tests</subject><subject>Stretching</subject><subject>Vibration</subject><subject>Vibration control</subject><subject>Wire</subject><issn>1755-1307</issn><issn>1755-1315</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNo9kEtLxDAQx4MouK5-BQl4rp1p2qY5yuILVvSg55CmE-nSl0kr9NvbpbKnmWH-D_gxdotwj1AUMcosi1BgFktYrhgwAcAztjk9zk87yEt2FcIBIJepUBv29kHe9b41nSVOv6aZzFj3He8dr-bOtLXlw9Q0NPPKtAN5HuYwUssXD6-7MJqmWQ2m-27oml040wS6-Z9b9vX0-Ll7ifbvz6-7h31kUQmMFFRGkkILaUUCSIqyBKdySsimUBKSKIrCpTk4k5SQg7VlkVlRqVRVWSrElt2tuYPvfyYKoz70k--WSp1kWEiJqLJFla8q6_sQPDk9-Lo1ftYI-ohOH6noIyG9oNOoV3TiD3oJYhM</recordid><startdate>20210401</startdate><enddate>20210401</enddate><creator>Majima, R</creator><creator>Hayashi, K</creator><creator>Saito, T</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ATCPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>PATMY</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PYCSY</scope></search><sort><creationdate>20210401</creationdate><title>Performance evaluation of dynamic pulley damper system for installation angle</title><author>Majima, R ; Hayashi, K ; Saito, T</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1931-90da7e91c04de30e73bb0f96e2ec40be1e3888f460fa2b060ccb85c3d949d5433</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Amplification</topic><topic>Buildings</topic><topic>Control systems</topic><topic>High rise buildings</topic><topic>Model accuracy</topic><topic>Parametric analysis</topic><topic>Performance evaluation</topic><topic>Pulleys</topic><topic>Seismic activity</topic><topic>Seismic response</topic><topic>Shake table tests</topic><topic>Stretching</topic><topic>Vibration</topic><topic>Vibration control</topic><topic>Wire</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Majima, R</creatorcontrib><creatorcontrib>Hayashi, K</creatorcontrib><creatorcontrib>Saito, T</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Agricultural &amp; Environmental Science Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection (Proquest) (PQ_SDU_P3)</collection><collection>Environmental Science Database</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Environmental Science Collection</collection><jtitle>IOP conference series. Earth and environmental science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Majima, R</au><au>Hayashi, K</au><au>Saito, T</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance evaluation of dynamic pulley damper system for installation angle</atitle><jtitle>IOP conference series. Earth and environmental science</jtitle><date>2021-04-01</date><risdate>2021</risdate><volume>708</volume><issue>1</issue><spage>12001</spage><pages>12001-</pages><issn>1755-1307</issn><eissn>1755-1315</eissn><abstract>Dynamic pulley damper system (DPDS) as an innovative methodology for a response control system using a block and tackle mechanism to provide enhanced vibration reduction in high-rise buildings, has been proposed. The key aspect of this system is to exponentially increase the damper movement using an amplification mechanism comprising movable pulleys and a wire. This paper presents the relation between the arrangement of the wire’s angles, particularly in the amplification part, and the vibration reduction effect. The DPDS is introduced into a center-core high-rise building. Two small building varieties with different core heights are designed; then, a wire is stretched between the frame and the core structures. The capability of the DPDS to control vibration is confirmed via the shaking table test. Additionally, the accuracy of the simulation models is verified by a comparison with the experimental results. Moreover, this paper includes a parametric analysis test to determine the wire-stretching angle for establishing the most efficient design. The results of the above analysis show that the wire-stretching angle influences the seismic performance of the DPDS.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1755-1315/708/1/012001</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1755-1307
ispartof IOP conference series. Earth and environmental science, 2021-04, Vol.708 (1), p.12001
issn 1755-1307
1755-1315
language eng
recordid cdi_proquest_journals_2518771195
source Publicly Available Content Database (Proquest) (PQ_SDU_P3)
subjects Amplification
Buildings
Control systems
High rise buildings
Model accuracy
Parametric analysis
Performance evaluation
Pulleys
Seismic activity
Seismic response
Shake table tests
Stretching
Vibration
Vibration control
Wire
title Performance evaluation of dynamic pulley damper system for installation angle
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T19%3A35%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20evaluation%20of%20dynamic%20pulley%20damper%20system%20for%20installation%20angle&rft.jtitle=IOP%20conference%20series.%20Earth%20and%20environmental%20science&rft.au=Majima,%20R&rft.date=2021-04-01&rft.volume=708&rft.issue=1&rft.spage=12001&rft.pages=12001-&rft.issn=1755-1307&rft.eissn=1755-1315&rft_id=info:doi/10.1088/1755-1315/708/1/012001&rft_dat=%3Cproquest_cross%3E2518771195%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1931-90da7e91c04de30e73bb0f96e2ec40be1e3888f460fa2b060ccb85c3d949d5433%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2518771195&rft_id=info:pmid/&rfr_iscdi=true