Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study

Aim: Scaling is important for maintenance of gingival and periodontal conditions. These procedures have a harmful effect on the dental hard tissues. The aim of this study was to investigate the effects of hand and ultrasonic instruments made of stainless and titanium on the surface properties of ena...

Full description

Saved in:
Bibliographic Details
Published in:Journal of international oral health 2020-11, Vol.12 (6), p.579-585
Main Authors: Al Ankily, Mahmoud, Makkeyah, Fatma, Bakr, Mahmoud, Shamel, Mohamed
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3
cites cdi_FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3
container_end_page 585
container_issue 6
container_start_page 579
container_title Journal of international oral health
container_volume 12
creator Al Ankily, Mahmoud
Makkeyah, Fatma
Bakr, Mahmoud
Shamel, Mohamed
description Aim: Scaling is important for maintenance of gingival and periodontal conditions. These procedures have a harmful effect on the dental hard tissues. The aim of this study was to investigate the effects of hand and ultrasonic instruments made of stainless and titanium on the surface properties of enamel. Materials and Methods: Forty extracted premolars were used in this in vitro study and were randomly divided into four groups (n = 10). Group I received ultrasonic scaling with stainless steel tip, group II received ultrasonic scaling with titanium tip, group III hand scaling with stainless steel tip, and group IV hand scaling with titanium tip. Scanning electron microscopy (SEM) was used to examine the enamel surface morphology. Surface roughness of enamel was measured at baseline and after the scaling simulation using atomic force microscopy (AFM). Differences between initial and final measurements of surface roughness (ΔRa) were analyzed using two-way analysis of variance (ANOVA) followed by post hoc pairwise comparisons between groups. Results: SEM revealed deeper scratches and more destructive changes on enamel surface in group IV, whereas other groups revealed less change. AFM revealed that a mean surface roughness difference (ΔRa) had the highest value with hand instruments using titanium curettes, whereas the lowest difference was found with ultrasonic tips using stainless-steel tips. Hand titanium curettes showed a statistically significant increase in ΔRa when compared to hand stainless steel curettes (P = 0.02) and ultrasonic titanium tips (P = 0.01). Hand stainless steel tips showed a statistically significant increase in ΔRa when compared to ultrasonic stainless steel tips (P = 0.02) and hand titanium curettes (P = 0.02). Conclusion: Scaling using ultrasonic stainless steel tips produce the least amount of surface roughness and damage to the tooth surface.
doi_str_mv 10.4103/JIOH.JIOH_121_20
format article
fullrecord <record><control><sourceid>gale_proqu</sourceid><recordid>TN_cdi_proquest_journals_2532729277</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A643441203</galeid><sourcerecordid>A643441203</sourcerecordid><originalsourceid>FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3</originalsourceid><addsrcrecordid>eNp1kc9LHDEUx4dioaLeewwUvO02v2Yy09sia1W2eGh7DtnkZSc6k6xJxmX_-8auokKbQPII308ej09VfSZ4zglmX2-ub6_mT4cklEiKP1THuBPNjIiuO3quBaftp-ospTtcVoMp5_Vx5ZbWgs4oWGRcKSP4jJJWg_MbNELug0lIeYNGlSE6NSQUPMo9IPBqhAGlKVqlAeWwDZuotv3-G1p45Dx6dDkG9HP5A6U8mf1p9dEWHM6e75Pq9-Xy18XVbHX7_fpisZpp3mI_q0ULjNAaw5qYpm1tC0rTModgWIiWrgXRTOFGwLpRtbEdBtutCeNgWFs3hp1UXw7_bmN4mCBleRem6EtLSWtGBe2oEK-pjRpAOm9DjkqPLmm5aDjjnFDMSmr-j1TZBkangwfryvs74PwN0IMacp_CMGUXfHofxIegjiGlCFZuoxtV3EuC5ZNT-VfnG6cFWR2QXRiKi3Q_TDuIcgRz78Puv5ysRScPlmWw8sUy-wMSoKy2</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2532729277</pqid></control><display><type>article</type><title>Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study</title><source>Medknow Open Access Journals</source><creator>Al Ankily, Mahmoud ; Makkeyah, Fatma ; Bakr, Mahmoud ; Shamel, Mohamed</creator><creatorcontrib>Al Ankily, Mahmoud ; Makkeyah, Fatma ; Bakr, Mahmoud ; Shamel, Mohamed</creatorcontrib><description>Aim: Scaling is important for maintenance of gingival and periodontal conditions. These procedures have a harmful effect on the dental hard tissues. The aim of this study was to investigate the effects of hand and ultrasonic instruments made of stainless and titanium on the surface properties of enamel. Materials and Methods: Forty extracted premolars were used in this in vitro study and were randomly divided into four groups (n = 10). Group I received ultrasonic scaling with stainless steel tip, group II received ultrasonic scaling with titanium tip, group III hand scaling with stainless steel tip, and group IV hand scaling with titanium tip. Scanning electron microscopy (SEM) was used to examine the enamel surface morphology. Surface roughness of enamel was measured at baseline and after the scaling simulation using atomic force microscopy (AFM). Differences between initial and final measurements of surface roughness (ΔRa) were analyzed using two-way analysis of variance (ANOVA) followed by post hoc pairwise comparisons between groups. Results: SEM revealed deeper scratches and more destructive changes on enamel surface in group IV, whereas other groups revealed less change. AFM revealed that a mean surface roughness difference (ΔRa) had the highest value with hand instruments using titanium curettes, whereas the lowest difference was found with ultrasonic tips using stainless-steel tips. Hand titanium curettes showed a statistically significant increase in ΔRa when compared to hand stainless steel curettes (P = 0.02) and ultrasonic titanium tips (P = 0.01). Hand stainless steel tips showed a statistically significant increase in ΔRa when compared to ultrasonic stainless steel tips (P = 0.02) and hand titanium curettes (P = 0.02). Conclusion: Scaling using ultrasonic stainless steel tips produce the least amount of surface roughness and damage to the tooth surface.</description><identifier>ISSN: 0976-7428</identifier><identifier>EISSN: 0976-1799</identifier><identifier>DOI: 10.4103/JIOH.JIOH_121_20</identifier><language>eng</language><publisher>Mumbai: Wolters Kluwer - Medknow Publications</publisher><subject>Atomic force microscopy ; Comparative analysis ; Dental enamel ; Dental equipment ; Enamel ; Measurement ; Mechanical properties ; Premolars ; Scaling ; Scanning electron microscopy ; Stainless steel ; Statistical analysis ; Surface properties ; Surface roughness ; Testing ; Titanium ; Variance analysis</subject><ispartof>Journal of international oral health, 2020-11, Vol.12 (6), p.579-585</ispartof><rights>COPYRIGHT 2020 Medknow Publications and Media Pvt. Ltd.</rights><rights>2020. This article is published under (http://creativecommons.org/licenses/by-nc-sa/3.0/) (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3</citedby><cites>FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27458,27924,27925</link.rule.ids></links><search><creatorcontrib>Al Ankily, Mahmoud</creatorcontrib><creatorcontrib>Makkeyah, Fatma</creatorcontrib><creatorcontrib>Bakr, Mahmoud</creatorcontrib><creatorcontrib>Shamel, Mohamed</creatorcontrib><title>Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study</title><title>Journal of international oral health</title><description>Aim: Scaling is important for maintenance of gingival and periodontal conditions. These procedures have a harmful effect on the dental hard tissues. The aim of this study was to investigate the effects of hand and ultrasonic instruments made of stainless and titanium on the surface properties of enamel. Materials and Methods: Forty extracted premolars were used in this in vitro study and were randomly divided into four groups (n = 10). Group I received ultrasonic scaling with stainless steel tip, group II received ultrasonic scaling with titanium tip, group III hand scaling with stainless steel tip, and group IV hand scaling with titanium tip. Scanning electron microscopy (SEM) was used to examine the enamel surface morphology. Surface roughness of enamel was measured at baseline and after the scaling simulation using atomic force microscopy (AFM). Differences between initial and final measurements of surface roughness (ΔRa) were analyzed using two-way analysis of variance (ANOVA) followed by post hoc pairwise comparisons between groups. Results: SEM revealed deeper scratches and more destructive changes on enamel surface in group IV, whereas other groups revealed less change. AFM revealed that a mean surface roughness difference (ΔRa) had the highest value with hand instruments using titanium curettes, whereas the lowest difference was found with ultrasonic tips using stainless-steel tips. Hand titanium curettes showed a statistically significant increase in ΔRa when compared to hand stainless steel curettes (P = 0.02) and ultrasonic titanium tips (P = 0.01). Hand stainless steel tips showed a statistically significant increase in ΔRa when compared to ultrasonic stainless steel tips (P = 0.02) and hand titanium curettes (P = 0.02). Conclusion: Scaling using ultrasonic stainless steel tips produce the least amount of surface roughness and damage to the tooth surface.</description><subject>Atomic force microscopy</subject><subject>Comparative analysis</subject><subject>Dental enamel</subject><subject>Dental equipment</subject><subject>Enamel</subject><subject>Measurement</subject><subject>Mechanical properties</subject><subject>Premolars</subject><subject>Scaling</subject><subject>Scanning electron microscopy</subject><subject>Stainless steel</subject><subject>Statistical analysis</subject><subject>Surface properties</subject><subject>Surface roughness</subject><subject>Testing</subject><subject>Titanium</subject><subject>Variance analysis</subject><issn>0976-7428</issn><issn>0976-1799</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNp1kc9LHDEUx4dioaLeewwUvO02v2Yy09sia1W2eGh7DtnkZSc6k6xJxmX_-8auokKbQPII308ej09VfSZ4zglmX2-ub6_mT4cklEiKP1THuBPNjIiuO3quBaftp-ospTtcVoMp5_Vx5ZbWgs4oWGRcKSP4jJJWg_MbNELug0lIeYNGlSE6NSQUPMo9IPBqhAGlKVqlAeWwDZuotv3-G1p45Dx6dDkG9HP5A6U8mf1p9dEWHM6e75Pq9-Xy18XVbHX7_fpisZpp3mI_q0ULjNAaw5qYpm1tC0rTModgWIiWrgXRTOFGwLpRtbEdBtutCeNgWFs3hp1UXw7_bmN4mCBleRem6EtLSWtGBe2oEK-pjRpAOm9DjkqPLmm5aDjjnFDMSmr-j1TZBkangwfryvs74PwN0IMacp_CMGUXfHofxIegjiGlCFZuoxtV3EuC5ZNT-VfnG6cFWR2QXRiKi3Q_TDuIcgRz78Puv5ysRScPlmWw8sUy-wMSoKy2</recordid><startdate>20201101</startdate><enddate>20201101</enddate><creator>Al Ankily, Mahmoud</creator><creator>Makkeyah, Fatma</creator><creator>Bakr, Mahmoud</creator><creator>Shamel, Mohamed</creator><general>Wolters Kluwer - Medknow Publications</general><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications &amp; Media Pvt. Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>04Q</scope><scope>04T</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8C1</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20201101</creationdate><title>Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study</title><author>Al Ankily, Mahmoud ; Makkeyah, Fatma ; Bakr, Mahmoud ; Shamel, Mohamed</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Atomic force microscopy</topic><topic>Comparative analysis</topic><topic>Dental enamel</topic><topic>Dental equipment</topic><topic>Enamel</topic><topic>Measurement</topic><topic>Mechanical properties</topic><topic>Premolars</topic><topic>Scaling</topic><topic>Scanning electron microscopy</topic><topic>Stainless steel</topic><topic>Statistical analysis</topic><topic>Surface properties</topic><topic>Surface roughness</topic><topic>Testing</topic><topic>Titanium</topic><topic>Variance analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Al Ankily, Mahmoud</creatorcontrib><creatorcontrib>Makkeyah, Fatma</creatorcontrib><creatorcontrib>Bakr, Mahmoud</creatorcontrib><creatorcontrib>Shamel, Mohamed</creatorcontrib><collection>CrossRef</collection><collection>India Database</collection><collection>India Database: Health &amp; Medicine</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Public Health Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>ProQuest Biological Science Journals</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of international oral health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al Ankily, Mahmoud</au><au>Makkeyah, Fatma</au><au>Bakr, Mahmoud</au><au>Shamel, Mohamed</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study</atitle><jtitle>Journal of international oral health</jtitle><date>2020-11-01</date><risdate>2020</risdate><volume>12</volume><issue>6</issue><spage>579</spage><epage>585</epage><pages>579-585</pages><issn>0976-7428</issn><eissn>0976-1799</eissn><abstract>Aim: Scaling is important for maintenance of gingival and periodontal conditions. These procedures have a harmful effect on the dental hard tissues. The aim of this study was to investigate the effects of hand and ultrasonic instruments made of stainless and titanium on the surface properties of enamel. Materials and Methods: Forty extracted premolars were used in this in vitro study and were randomly divided into four groups (n = 10). Group I received ultrasonic scaling with stainless steel tip, group II received ultrasonic scaling with titanium tip, group III hand scaling with stainless steel tip, and group IV hand scaling with titanium tip. Scanning electron microscopy (SEM) was used to examine the enamel surface morphology. Surface roughness of enamel was measured at baseline and after the scaling simulation using atomic force microscopy (AFM). Differences between initial and final measurements of surface roughness (ΔRa) were analyzed using two-way analysis of variance (ANOVA) followed by post hoc pairwise comparisons between groups. Results: SEM revealed deeper scratches and more destructive changes on enamel surface in group IV, whereas other groups revealed less change. AFM revealed that a mean surface roughness difference (ΔRa) had the highest value with hand instruments using titanium curettes, whereas the lowest difference was found with ultrasonic tips using stainless-steel tips. Hand titanium curettes showed a statistically significant increase in ΔRa when compared to hand stainless steel curettes (P = 0.02) and ultrasonic titanium tips (P = 0.01). Hand stainless steel tips showed a statistically significant increase in ΔRa when compared to ultrasonic stainless steel tips (P = 0.02) and hand titanium curettes (P = 0.02). Conclusion: Scaling using ultrasonic stainless steel tips produce the least amount of surface roughness and damage to the tooth surface.</abstract><cop>Mumbai</cop><pub>Wolters Kluwer - Medknow Publications</pub><doi>10.4103/JIOH.JIOH_121_20</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0976-7428
ispartof Journal of international oral health, 2020-11, Vol.12 (6), p.579-585
issn 0976-7428
0976-1799
language eng
recordid cdi_proquest_journals_2532729277
source Medknow Open Access Journals
subjects Atomic force microscopy
Comparative analysis
Dental enamel
Dental equipment
Enamel
Measurement
Mechanical properties
Premolars
Scaling
Scanning electron microscopy
Stainless steel
Statistical analysis
Surface properties
Surface roughness
Testing
Titanium
Variance analysis
title Effect of different scaling methods and materials on the enamel surface topography: An in vitro SEM study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T06%3A39%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_proqu&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20different%20scaling%20methods%20and%20materials%20on%20the%20enamel%20surface%20topography:%20An%20in%20vitro%20SEM%20study&rft.jtitle=Journal%20of%20international%20oral%20health&rft.au=Al%20Ankily,%20Mahmoud&rft.date=2020-11-01&rft.volume=12&rft.issue=6&rft.spage=579&rft.epage=585&rft.pages=579-585&rft.issn=0976-7428&rft.eissn=0976-1799&rft_id=info:doi/10.4103/JIOH.JIOH_121_20&rft_dat=%3Cgale_proqu%3EA643441203%3C/gale_proqu%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c480n-578e31250eb1d688f8eac27997307782b71c3a067eb6a5df90ef9b134ed3856d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2532729277&rft_id=info:pmid/&rft_galeid=A643441203&rfr_iscdi=true