Loading…
Automatic Segmentation of Coronary Arteries in X-ray Angiograms using Multiscale Analysis and Artificial Neural Networks
This paper presents a novel method for the automatic segmentation of coronary arteries in X-ray angiograms, based on multiscale analysis and neural networks. The multiscale analysis is performed by using Gaussian filters in the spatial domain and Gabor filters in the frequency domain, which are used...
Saved in:
Published in: | Applied sciences 2019-12, Vol.9 (24), p.5507 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93 |
---|---|
cites | cdi_FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93 |
container_end_page | |
container_issue | 24 |
container_start_page | 5507 |
container_title | Applied sciences |
container_volume | 9 |
creator | Cervantes-Sanchez, Fernando Cruz-Aceves, Ivan Hernandez-Aguirre, Arturo Hernandez-Gonzalez, Martha Alicia Solorio-Meza, Sergio Eduardo |
description | This paper presents a novel method for the automatic segmentation of coronary arteries in X-ray angiograms, based on multiscale analysis and neural networks. The multiscale analysis is performed by using Gaussian filters in the spatial domain and Gabor filters in the frequency domain, which are used as inputs by a multilayer perceptron (MLP) for the enhancement of vessel-like structures. The optimal design of the MLP is selected following a statistical comparative analysis, using a training set of 100 angiograms, and the area under the ROC curve ( A z ) for assessment of the detection performance. The detection results of the proposed method are compared with eleven state-of-the-art blood vessel enhancement methods, obtaining the highest performance of A z = 0.9775 , with a test set of 30 angiograms. The database of 130 X-ray coronary angiograms has been outlined by a specialist and approved by a medical ethics committee. On the other hand, the vessel extraction technique was selected from fourteen binary classification algorithms applied to the multiscale filter response. Finally, the proposed segmentation method is compared with twelve state-of-the-art vessel segmentation methods in terms of six binary evaluation metrics, where the proposed method provided the most accurate coronary arteries segmentation with a classification rate of 0.9698 and Dice coefficient of 0.6857 , using the test set of angiograms. In addition to the experimental results, the performance in the detection and segmentation steps of the proposed method have also shown that it can be highly suitable for systems that perform computer-aided diagnosis in X-ray imaging. |
doi_str_mv | 10.3390/app9245507 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2533771257</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2533771257</sourcerecordid><originalsourceid>FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93</originalsourceid><addsrcrecordid>eNpNUE1LAzEQDaJgqb34CwLehNVks0maYyl-QdWDCt6WNJ0sqbvJmmTR_ntXK-hc3mPmzWPmIXRKyQVjilzqvldlxTmRB2hSEikKVlF5-I8fo1lKWzKWomxOyQR9LoYcOp2dwU_QdODzyIPHweJliMHruMOLmCE6SNh5_FpEPXZ840ITdZfwkJxv8P3QZpeMbmGc6XaXXMLab75XnXXG6RY_wBB_IH-E-JZO0JHVbYLZL07Ry_XV8_K2WD3e3C0Xq8KUiufCSl6JuV5zTcRaCc6MMVIaA8YakAyM2JSiIrYiwLnSklECIPlcC2UZ3yg2RWd73z6G9wFSrrdhiOONqS45Y1LSkstRdb5XmRhSimDrPrpufL6mpP4Ot_4Ll30BDBluUg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2533771257</pqid></control><display><type>article</type><title>Automatic Segmentation of Coronary Arteries in X-ray Angiograms using Multiscale Analysis and Artificial Neural Networks</title><source>Publicly Available Content Database</source><creator>Cervantes-Sanchez, Fernando ; Cruz-Aceves, Ivan ; Hernandez-Aguirre, Arturo ; Hernandez-Gonzalez, Martha Alicia ; Solorio-Meza, Sergio Eduardo</creator><creatorcontrib>Cervantes-Sanchez, Fernando ; Cruz-Aceves, Ivan ; Hernandez-Aguirre, Arturo ; Hernandez-Gonzalez, Martha Alicia ; Solorio-Meza, Sergio Eduardo</creatorcontrib><description>This paper presents a novel method for the automatic segmentation of coronary arteries in X-ray angiograms, based on multiscale analysis and neural networks. The multiscale analysis is performed by using Gaussian filters in the spatial domain and Gabor filters in the frequency domain, which are used as inputs by a multilayer perceptron (MLP) for the enhancement of vessel-like structures. The optimal design of the MLP is selected following a statistical comparative analysis, using a training set of 100 angiograms, and the area under the ROC curve ( A z ) for assessment of the detection performance. The detection results of the proposed method are compared with eleven state-of-the-art blood vessel enhancement methods, obtaining the highest performance of A z = 0.9775 , with a test set of 30 angiograms. The database of 130 X-ray coronary angiograms has been outlined by a specialist and approved by a medical ethics committee. On the other hand, the vessel extraction technique was selected from fourteen binary classification algorithms applied to the multiscale filter response. Finally, the proposed segmentation method is compared with twelve state-of-the-art vessel segmentation methods in terms of six binary evaluation metrics, where the proposed method provided the most accurate coronary arteries segmentation with a classification rate of 0.9698 and Dice coefficient of 0.6857 , using the test set of angiograms. In addition to the experimental results, the performance in the detection and segmentation steps of the proposed method have also shown that it can be highly suitable for systems that perform computer-aided diagnosis in X-ray imaging.</description><identifier>ISSN: 2076-3417</identifier><identifier>EISSN: 2076-3417</identifier><identifier>DOI: 10.3390/app9245507</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Cardiovascular disease ; Classification ; Comparative analysis ; Coronary artery ; Coronary vessels ; Eigenvalues ; Filters ; Gabor filters ; Methods ; Multilayer perceptrons ; Multiscale analysis ; Neural networks ; Test sets ; Veins & arteries ; X ray imagery</subject><ispartof>Applied sciences, 2019-12, Vol.9 (24), p.5507</ispartof><rights>2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93</citedby><cites>FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93</cites><orcidid>0000-0002-7501-6088 ; 0000-0002-5197-2059 ; 0000-0002-6903-2233 ; 0000-0003-0652-2750</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2533771257/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2533771257?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,75126</link.rule.ids></links><search><creatorcontrib>Cervantes-Sanchez, Fernando</creatorcontrib><creatorcontrib>Cruz-Aceves, Ivan</creatorcontrib><creatorcontrib>Hernandez-Aguirre, Arturo</creatorcontrib><creatorcontrib>Hernandez-Gonzalez, Martha Alicia</creatorcontrib><creatorcontrib>Solorio-Meza, Sergio Eduardo</creatorcontrib><title>Automatic Segmentation of Coronary Arteries in X-ray Angiograms using Multiscale Analysis and Artificial Neural Networks</title><title>Applied sciences</title><description>This paper presents a novel method for the automatic segmentation of coronary arteries in X-ray angiograms, based on multiscale analysis and neural networks. The multiscale analysis is performed by using Gaussian filters in the spatial domain and Gabor filters in the frequency domain, which are used as inputs by a multilayer perceptron (MLP) for the enhancement of vessel-like structures. The optimal design of the MLP is selected following a statistical comparative analysis, using a training set of 100 angiograms, and the area under the ROC curve ( A z ) for assessment of the detection performance. The detection results of the proposed method are compared with eleven state-of-the-art blood vessel enhancement methods, obtaining the highest performance of A z = 0.9775 , with a test set of 30 angiograms. The database of 130 X-ray coronary angiograms has been outlined by a specialist and approved by a medical ethics committee. On the other hand, the vessel extraction technique was selected from fourteen binary classification algorithms applied to the multiscale filter response. Finally, the proposed segmentation method is compared with twelve state-of-the-art vessel segmentation methods in terms of six binary evaluation metrics, where the proposed method provided the most accurate coronary arteries segmentation with a classification rate of 0.9698 and Dice coefficient of 0.6857 , using the test set of angiograms. In addition to the experimental results, the performance in the detection and segmentation steps of the proposed method have also shown that it can be highly suitable for systems that perform computer-aided diagnosis in X-ray imaging.</description><subject>Cardiovascular disease</subject><subject>Classification</subject><subject>Comparative analysis</subject><subject>Coronary artery</subject><subject>Coronary vessels</subject><subject>Eigenvalues</subject><subject>Filters</subject><subject>Gabor filters</subject><subject>Methods</subject><subject>Multilayer perceptrons</subject><subject>Multiscale analysis</subject><subject>Neural networks</subject><subject>Test sets</subject><subject>Veins & arteries</subject><subject>X ray imagery</subject><issn>2076-3417</issn><issn>2076-3417</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpNUE1LAzEQDaJgqb34CwLehNVks0maYyl-QdWDCt6WNJ0sqbvJmmTR_ntXK-hc3mPmzWPmIXRKyQVjilzqvldlxTmRB2hSEikKVlF5-I8fo1lKWzKWomxOyQR9LoYcOp2dwU_QdODzyIPHweJliMHruMOLmCE6SNh5_FpEPXZ840ITdZfwkJxv8P3QZpeMbmGc6XaXXMLab75XnXXG6RY_wBB_IH-E-JZO0JHVbYLZL07Ry_XV8_K2WD3e3C0Xq8KUiufCSl6JuV5zTcRaCc6MMVIaA8YakAyM2JSiIrYiwLnSklECIPlcC2UZ3yg2RWd73z6G9wFSrrdhiOONqS45Y1LSkstRdb5XmRhSimDrPrpufL6mpP4Ot_4Ll30BDBluUg</recordid><startdate>20191201</startdate><enddate>20191201</enddate><creator>Cervantes-Sanchez, Fernando</creator><creator>Cruz-Aceves, Ivan</creator><creator>Hernandez-Aguirre, Arturo</creator><creator>Hernandez-Gonzalez, Martha Alicia</creator><creator>Solorio-Meza, Sergio Eduardo</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-7501-6088</orcidid><orcidid>https://orcid.org/0000-0002-5197-2059</orcidid><orcidid>https://orcid.org/0000-0002-6903-2233</orcidid><orcidid>https://orcid.org/0000-0003-0652-2750</orcidid></search><sort><creationdate>20191201</creationdate><title>Automatic Segmentation of Coronary Arteries in X-ray Angiograms using Multiscale Analysis and Artificial Neural Networks</title><author>Cervantes-Sanchez, Fernando ; Cruz-Aceves, Ivan ; Hernandez-Aguirre, Arturo ; Hernandez-Gonzalez, Martha Alicia ; Solorio-Meza, Sergio Eduardo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Cardiovascular disease</topic><topic>Classification</topic><topic>Comparative analysis</topic><topic>Coronary artery</topic><topic>Coronary vessels</topic><topic>Eigenvalues</topic><topic>Filters</topic><topic>Gabor filters</topic><topic>Methods</topic><topic>Multilayer perceptrons</topic><topic>Multiscale analysis</topic><topic>Neural networks</topic><topic>Test sets</topic><topic>Veins & arteries</topic><topic>X ray imagery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cervantes-Sanchez, Fernando</creatorcontrib><creatorcontrib>Cruz-Aceves, Ivan</creatorcontrib><creatorcontrib>Hernandez-Aguirre, Arturo</creatorcontrib><creatorcontrib>Hernandez-Gonzalez, Martha Alicia</creatorcontrib><creatorcontrib>Solorio-Meza, Sergio Eduardo</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Applied sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cervantes-Sanchez, Fernando</au><au>Cruz-Aceves, Ivan</au><au>Hernandez-Aguirre, Arturo</au><au>Hernandez-Gonzalez, Martha Alicia</au><au>Solorio-Meza, Sergio Eduardo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automatic Segmentation of Coronary Arteries in X-ray Angiograms using Multiscale Analysis and Artificial Neural Networks</atitle><jtitle>Applied sciences</jtitle><date>2019-12-01</date><risdate>2019</risdate><volume>9</volume><issue>24</issue><spage>5507</spage><pages>5507-</pages><issn>2076-3417</issn><eissn>2076-3417</eissn><abstract>This paper presents a novel method for the automatic segmentation of coronary arteries in X-ray angiograms, based on multiscale analysis and neural networks. The multiscale analysis is performed by using Gaussian filters in the spatial domain and Gabor filters in the frequency domain, which are used as inputs by a multilayer perceptron (MLP) for the enhancement of vessel-like structures. The optimal design of the MLP is selected following a statistical comparative analysis, using a training set of 100 angiograms, and the area under the ROC curve ( A z ) for assessment of the detection performance. The detection results of the proposed method are compared with eleven state-of-the-art blood vessel enhancement methods, obtaining the highest performance of A z = 0.9775 , with a test set of 30 angiograms. The database of 130 X-ray coronary angiograms has been outlined by a specialist and approved by a medical ethics committee. On the other hand, the vessel extraction technique was selected from fourteen binary classification algorithms applied to the multiscale filter response. Finally, the proposed segmentation method is compared with twelve state-of-the-art vessel segmentation methods in terms of six binary evaluation metrics, where the proposed method provided the most accurate coronary arteries segmentation with a classification rate of 0.9698 and Dice coefficient of 0.6857 , using the test set of angiograms. In addition to the experimental results, the performance in the detection and segmentation steps of the proposed method have also shown that it can be highly suitable for systems that perform computer-aided diagnosis in X-ray imaging.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/app9245507</doi><orcidid>https://orcid.org/0000-0002-7501-6088</orcidid><orcidid>https://orcid.org/0000-0002-5197-2059</orcidid><orcidid>https://orcid.org/0000-0002-6903-2233</orcidid><orcidid>https://orcid.org/0000-0003-0652-2750</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2076-3417 |
ispartof | Applied sciences, 2019-12, Vol.9 (24), p.5507 |
issn | 2076-3417 2076-3417 |
language | eng |
recordid | cdi_proquest_journals_2533771257 |
source | Publicly Available Content Database |
subjects | Cardiovascular disease Classification Comparative analysis Coronary artery Coronary vessels Eigenvalues Filters Gabor filters Methods Multilayer perceptrons Multiscale analysis Neural networks Test sets Veins & arteries X ray imagery |
title | Automatic Segmentation of Coronary Arteries in X-ray Angiograms using Multiscale Analysis and Artificial Neural Networks |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T07%3A08%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automatic%20Segmentation%20of%20Coronary%20Arteries%20in%20X-ray%20Angiograms%20using%20Multiscale%20Analysis%20and%20Artificial%20Neural%20Networks&rft.jtitle=Applied%20sciences&rft.au=Cervantes-Sanchez,%20Fernando&rft.date=2019-12-01&rft.volume=9&rft.issue=24&rft.spage=5507&rft.pages=5507-&rft.issn=2076-3417&rft.eissn=2076-3417&rft_id=info:doi/10.3390/app9245507&rft_dat=%3Cproquest_cross%3E2533771257%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c295t-f75468ab5a06b9653ccc77ccecfce73ec6d2640f40e559a7310ee758a69f35d93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2533771257&rft_id=info:pmid/&rfr_iscdi=true |