Loading…
Biomimetic Control of Myoelectric Prosthetic Hand Based on a Lambda-type Muscle Model
Myoelectric prosthetic hands are intended to replace the function of the amputee's lost arm. Therefore, developing robotic prosthetics that can mimic not only the appearance and functionality of humans but also characteristics unique to human movements is paramount. Although the impedance model...
Saved in:
Published in: | arXiv.org 2021-05 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Furui, Akira Nakagaki, Kosuke Tsuji, Toshio |
description | Myoelectric prosthetic hands are intended to replace the function of the amputee's lost arm. Therefore, developing robotic prosthetics that can mimic not only the appearance and functionality of humans but also characteristics unique to human movements is paramount. Although the impedance model was proposed to realize biomimetic control, this model cannot replicate the characteristics of human movements effectively because the joint angle always converges to the equilibrium position during muscle relaxation. This paper proposes a novel biomimetic control method for myoelectric prosthetic hands integrating the impedance model with the concept of the \(\lambda\)-type muscle model. The proposed method can dynamically control the joint equilibrium position, according to the state of the muscle, and can maintain the joint angle naturally during muscle relaxation. The effectiveness of the proposed method is evaluated through simulations and a series of experiments on non-amputee participants. The experimental results, based on comparison with the actual human joint angles, suggest that the proposed method has a better correlation with the actual human motion than the conventional methods. Additionally, the control experiments showed that the proposed method could achieve a natural prosthetic hand movement similar to that of a human, thereby allowing voluntary hand opening and closing movements. |
doi_str_mv | 10.48550/arxiv.2105.14215 |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2535637093</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2535637093</sourcerecordid><originalsourceid>FETCH-LOGICAL-a523-3f5aedc6b0139cffa322061fa078c376cd6fdbd3df59e34a9e458fec1d3f49d13</originalsourceid><addsrcrecordid>eNotjUFLwzAYhoMgOOZ-gLeA59YkX5K2R1fUDTr0MM8jTb5gR9vMJhX37x3q6YGXh_ch5I6zXJZKsQczfXdfueBM5VwKrq7IQgDwrJRC3JBVjEfGmNCFUAoW5H3dhaEbMHWW1mFMU-hp8HR3DtijTdNlfptCTB-_xsaMjq5NREfDSA1tzNA6k6XzCelujra_IDjsb8m1N33E1T-XZP_8tK83WfP6sq0fm8woARl4ZdBZ3TIOlfXegBBMc29YUVootHXau9aB86pCkKZCqUqPljvwsnIcluT-7_Y0hc8ZYzocwzyNl-JBKFAaClYB_ACy5FKn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2535637093</pqid></control><display><type>article</type><title>Biomimetic Control of Myoelectric Prosthetic Hand Based on a Lambda-type Muscle Model</title><source>Publicly Available Content (ProQuest)</source><creator>Furui, Akira ; Nakagaki, Kosuke ; Tsuji, Toshio</creator><creatorcontrib>Furui, Akira ; Nakagaki, Kosuke ; Tsuji, Toshio</creatorcontrib><description>Myoelectric prosthetic hands are intended to replace the function of the amputee's lost arm. Therefore, developing robotic prosthetics that can mimic not only the appearance and functionality of humans but also characteristics unique to human movements is paramount. Although the impedance model was proposed to realize biomimetic control, this model cannot replicate the characteristics of human movements effectively because the joint angle always converges to the equilibrium position during muscle relaxation. This paper proposes a novel biomimetic control method for myoelectric prosthetic hands integrating the impedance model with the concept of the \(\lambda\)-type muscle model. The proposed method can dynamically control the joint equilibrium position, according to the state of the muscle, and can maintain the joint angle naturally during muscle relaxation. The effectiveness of the proposed method is evaluated through simulations and a series of experiments on non-amputee participants. The experimental results, based on comparison with the actual human joint angles, suggest that the proposed method has a better correlation with the actual human motion than the conventional methods. Additionally, the control experiments showed that the proposed method could achieve a natural prosthetic hand movement similar to that of a human, thereby allowing voluntary hand opening and closing movements.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.2105.14215</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Biomimetics ; Control methods ; Human motion ; Impedance ; Joints (anatomy) ; Muscles ; Myoelectricity ; Prostheses</subject><ispartof>arXiv.org, 2021-05</ispartof><rights>2021. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2535637093?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25753,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Furui, Akira</creatorcontrib><creatorcontrib>Nakagaki, Kosuke</creatorcontrib><creatorcontrib>Tsuji, Toshio</creatorcontrib><title>Biomimetic Control of Myoelectric Prosthetic Hand Based on a Lambda-type Muscle Model</title><title>arXiv.org</title><description>Myoelectric prosthetic hands are intended to replace the function of the amputee's lost arm. Therefore, developing robotic prosthetics that can mimic not only the appearance and functionality of humans but also characteristics unique to human movements is paramount. Although the impedance model was proposed to realize biomimetic control, this model cannot replicate the characteristics of human movements effectively because the joint angle always converges to the equilibrium position during muscle relaxation. This paper proposes a novel biomimetic control method for myoelectric prosthetic hands integrating the impedance model with the concept of the \(\lambda\)-type muscle model. The proposed method can dynamically control the joint equilibrium position, according to the state of the muscle, and can maintain the joint angle naturally during muscle relaxation. The effectiveness of the proposed method is evaluated through simulations and a series of experiments on non-amputee participants. The experimental results, based on comparison with the actual human joint angles, suggest that the proposed method has a better correlation with the actual human motion than the conventional methods. Additionally, the control experiments showed that the proposed method could achieve a natural prosthetic hand movement similar to that of a human, thereby allowing voluntary hand opening and closing movements.</description><subject>Biomimetics</subject><subject>Control methods</subject><subject>Human motion</subject><subject>Impedance</subject><subject>Joints (anatomy)</subject><subject>Muscles</subject><subject>Myoelectricity</subject><subject>Prostheses</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNotjUFLwzAYhoMgOOZ-gLeA59YkX5K2R1fUDTr0MM8jTb5gR9vMJhX37x3q6YGXh_ch5I6zXJZKsQczfXdfueBM5VwKrq7IQgDwrJRC3JBVjEfGmNCFUAoW5H3dhaEbMHWW1mFMU-hp8HR3DtijTdNlfptCTB-_xsaMjq5NREfDSA1tzNA6k6XzCelujra_IDjsb8m1N33E1T-XZP_8tK83WfP6sq0fm8woARl4ZdBZ3TIOlfXegBBMc29YUVootHXau9aB86pCkKZCqUqPljvwsnIcluT-7_Y0hc8ZYzocwzyNl-JBKFAaClYB_ACy5FKn</recordid><startdate>20210529</startdate><enddate>20210529</enddate><creator>Furui, Akira</creator><creator>Nakagaki, Kosuke</creator><creator>Tsuji, Toshio</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20210529</creationdate><title>Biomimetic Control of Myoelectric Prosthetic Hand Based on a Lambda-type Muscle Model</title><author>Furui, Akira ; Nakagaki, Kosuke ; Tsuji, Toshio</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a523-3f5aedc6b0139cffa322061fa078c376cd6fdbd3df59e34a9e458fec1d3f49d13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Biomimetics</topic><topic>Control methods</topic><topic>Human motion</topic><topic>Impedance</topic><topic>Joints (anatomy)</topic><topic>Muscles</topic><topic>Myoelectricity</topic><topic>Prostheses</topic><toplevel>online_resources</toplevel><creatorcontrib>Furui, Akira</creatorcontrib><creatorcontrib>Nakagaki, Kosuke</creatorcontrib><creatorcontrib>Tsuji, Toshio</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Furui, Akira</au><au>Nakagaki, Kosuke</au><au>Tsuji, Toshio</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Biomimetic Control of Myoelectric Prosthetic Hand Based on a Lambda-type Muscle Model</atitle><jtitle>arXiv.org</jtitle><date>2021-05-29</date><risdate>2021</risdate><eissn>2331-8422</eissn><abstract>Myoelectric prosthetic hands are intended to replace the function of the amputee's lost arm. Therefore, developing robotic prosthetics that can mimic not only the appearance and functionality of humans but also characteristics unique to human movements is paramount. Although the impedance model was proposed to realize biomimetic control, this model cannot replicate the characteristics of human movements effectively because the joint angle always converges to the equilibrium position during muscle relaxation. This paper proposes a novel biomimetic control method for myoelectric prosthetic hands integrating the impedance model with the concept of the \(\lambda\)-type muscle model. The proposed method can dynamically control the joint equilibrium position, according to the state of the muscle, and can maintain the joint angle naturally during muscle relaxation. The effectiveness of the proposed method is evaluated through simulations and a series of experiments on non-amputee participants. The experimental results, based on comparison with the actual human joint angles, suggest that the proposed method has a better correlation with the actual human motion than the conventional methods. Additionally, the control experiments showed that the proposed method could achieve a natural prosthetic hand movement similar to that of a human, thereby allowing voluntary hand opening and closing movements.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.2105.14215</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2021-05 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_2535637093 |
source | Publicly Available Content (ProQuest) |
subjects | Biomimetics Control methods Human motion Impedance Joints (anatomy) Muscles Myoelectricity Prostheses |
title | Biomimetic Control of Myoelectric Prosthetic Hand Based on a Lambda-type Muscle Model |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T07%3A38%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Biomimetic%20Control%20of%20Myoelectric%20Prosthetic%20Hand%20Based%20on%20a%20Lambda-type%20Muscle%20Model&rft.jtitle=arXiv.org&rft.au=Furui,%20Akira&rft.date=2021-05-29&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.2105.14215&rft_dat=%3Cproquest%3E2535637093%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a523-3f5aedc6b0139cffa322061fa078c376cd6fdbd3df59e34a9e458fec1d3f49d13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2535637093&rft_id=info:pmid/&rfr_iscdi=true |