Loading…

Fast response transient behaviour of a coaxial thermal probe and recovery of surface heat flux for shock tube flows

•In house fabrication of fast response miniature coaxial thermal probe.•Exposure of coaxial thermal probe harsh flow environments in a shock tube.•Response behaviour of coaxial probe in millisecond flow duration.•Stagnation heat flux determination from temperature histories.•Performance evaluation o...

Full description

Saved in:
Bibliographic Details
Published in:Experimental thermal and fluid science 2021-09, Vol.127, p.110427, Article 110427
Main Authors: Rout, Anil Kumar, Agarwal, Sumit, Sahoo, Niranjan, kalita, Pankaj
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•In house fabrication of fast response miniature coaxial thermal probe.•Exposure of coaxial thermal probe harsh flow environments in a shock tube.•Response behaviour of coaxial probe in millisecond flow duration.•Stagnation heat flux determination from temperature histories.•Performance evaluation of co-axial thermal probe against a silver thin film gauge. The magnitude of surface heat flux and its accurate estimation are very crucial owing to their applicability in impulsive thermal loads for high-speed flights. The correctness of such heat flux is associated with the implications from highly responsive thermal sensors in ground-based aerodynamic studies. In the present study, the performance effectiveness of an indigenous, in-house-made coaxial thermal probe (CTP) is validated against a standard silver thin film gauge (TFG) counterpart. The thermal probe has been fabricated in-house from two metal alloys; chromel (3.25 mm diameter and 10 mm length) and constantan (0.91 mm diameter and 15 mm length), by disposing one in the annulus of another coaxially, subsequently clubbed by a thin layer of epoxy in between them. Similarly, the thin film gauge is fabricated by putting silver paste (~1 µm thickness) on the pyrex substrate (3.25 mm diameter, 10 mm length). The fabrication process is followed by different calibration activities to determine the characteristics constants for sensors (sensitivity, thermal product value for CTP, and temperature coefficient of resistance for TFG). Both the probes are tested in a highly transient environment in a shock tube that generates high density, high pressure, and high enthalpy flows. The response time of the CTP and TFG are found to be 265 µs and 240 µs, respectively. The heat flux values estimated through temperature responses are having a nice match for CTP as well as TFG with a deviation in peak heat flux value within a range of ±2%. A similar trend and magnitude are also re-assured through numerical simulation within an uncertainty band of ±1.5%. The exhaustive study carried out in a shock tube has assured the performance and reliability of a CTP. Hence, it is recommended as an effective heat flux sensor for routine measurements in impulsive heat loadings.
ISSN:0894-1777
1879-2286
DOI:10.1016/j.expthermflusci.2021.110427