Loading…
Exergy analysis of cascade refrigeration system working with refrigerant pairs R41-R404A and R41-R161
In this paper, a comparative study of vapour cascade refrigeration system performance with R41 - R161 and R41 - R404A refrigerant couples have been presented to find out best suited refrigerant between R161 and R404A in the high temperature circuit. A mathematical model has been developed using the...
Saved in:
Published in: | IOP conference series. Materials Science and Engineering 2018-06, Vol.377 (1), p.12036 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3 |
---|---|
cites | cdi_FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3 |
container_end_page | |
container_issue | 1 |
container_start_page | 12036 |
container_title | IOP conference series. Materials Science and Engineering |
container_volume | 377 |
creator | Roy, Ranendra Mandal, Bijan Kumar |
description | In this paper, a comparative study of vapour cascade refrigeration system performance with R41 - R161 and R41 - R404A refrigerant couples have been presented to find out best suited refrigerant between R161 and R404A in the high temperature circuit. A mathematical model has been developed using the basic equations of refrigeration system for the calculation of basic performance parameters energetically and exergetically. Few parameters have been assumed to carry out the simulation. Simulated results show that R41 - R161 gives better results than R41 - R404A in all aspects, i.e. compressor power, COP, exergy destruction and exergetic efficiency wise. Exergetic analysis reveals that maximum and minimum losses for R41 - R161 occurs in the high temperature circuit compressor and evaporator respectively. Therefore, R161 can be a promising refrigerant to R404A due to its better thermophysical and environmental properties. |
doi_str_mv | 10.1088/1757-899X/377/1/012036 |
format | article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_journals_2556944594</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2556944594</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3</originalsourceid><addsrcrecordid>eNqFkEtLw0AUhQdRsFb_ggy4cRMzr8wky1LqAypCVXA3TOdRp7ZJnEmp-femRFoEwdW9l3vOgfMBcInRDUZ5nmKRiSQvireUCpHiFGGCKD8Cg_3jeL_n-BScxbhEiAvG0ADYyZcNixaqUq3a6COsHNQqamUsDNYFv7BBNb4qYWxjY9dwW4UPXy7g1jfvB0XZwFr5EOGM4WTGEBt1iaa_MMfn4MSpVbQXP3MIXm8nL-P7ZPp09zAeTRNNCeGJI0hbnVlBOcpVISzRQmjnjKGFYXPDCUWIoMwWc57NmWOGaGNczjjWCHNDh-Cqz61D9bmxsZHLahO6alGSLOMFY1nBOhXvVTpUMXYdZB38WoVWYiR3SOWOltyRkx1SiWWPtDOS3uir-pD8r-n6D9Pj8-SXTNbG0W_oLITk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2556944594</pqid></control><display><type>article</type><title>Exergy analysis of cascade refrigeration system working with refrigerant pairs R41-R404A and R41-R161</title><source>Publicly Available Content Database</source><source>Free Full-Text Journals in Chemistry</source><creator>Roy, Ranendra ; Mandal, Bijan Kumar</creator><creatorcontrib>Roy, Ranendra ; Mandal, Bijan Kumar</creatorcontrib><description>In this paper, a comparative study of vapour cascade refrigeration system performance with R41 - R161 and R41 - R404A refrigerant couples have been presented to find out best suited refrigerant between R161 and R404A in the high temperature circuit. A mathematical model has been developed using the basic equations of refrigeration system for the calculation of basic performance parameters energetically and exergetically. Few parameters have been assumed to carry out the simulation. Simulated results show that R41 - R161 gives better results than R41 - R404A in all aspects, i.e. compressor power, COP, exergy destruction and exergetic efficiency wise. Exergetic analysis reveals that maximum and minimum losses for R41 - R161 occurs in the high temperature circuit compressor and evaporator respectively. Therefore, R161 can be a promising refrigerant to R404A due to its better thermophysical and environmental properties.</description><identifier>ISSN: 1757-8981</identifier><identifier>EISSN: 1757-899X</identifier><identifier>DOI: 10.1088/1757-899X/377/1/012036</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Circuits ; Comparative studies ; Evaporators ; Exergy ; High temperature ; Parameters ; Refrigerants ; Refrigeration ; Thermophysical properties</subject><ispartof>IOP conference series. Materials Science and Engineering, 2018-06, Vol.377 (1), p.12036</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2018. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3</citedby><cites>FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2556944594?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,25731,27901,27902,36989,44566</link.rule.ids></links><search><creatorcontrib>Roy, Ranendra</creatorcontrib><creatorcontrib>Mandal, Bijan Kumar</creatorcontrib><title>Exergy analysis of cascade refrigeration system working with refrigerant pairs R41-R404A and R41-R161</title><title>IOP conference series. Materials Science and Engineering</title><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><description>In this paper, a comparative study of vapour cascade refrigeration system performance with R41 - R161 and R41 - R404A refrigerant couples have been presented to find out best suited refrigerant between R161 and R404A in the high temperature circuit. A mathematical model has been developed using the basic equations of refrigeration system for the calculation of basic performance parameters energetically and exergetically. Few parameters have been assumed to carry out the simulation. Simulated results show that R41 - R161 gives better results than R41 - R404A in all aspects, i.e. compressor power, COP, exergy destruction and exergetic efficiency wise. Exergetic analysis reveals that maximum and minimum losses for R41 - R161 occurs in the high temperature circuit compressor and evaporator respectively. Therefore, R161 can be a promising refrigerant to R404A due to its better thermophysical and environmental properties.</description><subject>Circuits</subject><subject>Comparative studies</subject><subject>Evaporators</subject><subject>Exergy</subject><subject>High temperature</subject><subject>Parameters</subject><subject>Refrigerants</subject><subject>Refrigeration</subject><subject>Thermophysical properties</subject><issn>1757-8981</issn><issn>1757-899X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqFkEtLw0AUhQdRsFb_ggy4cRMzr8wky1LqAypCVXA3TOdRp7ZJnEmp-femRFoEwdW9l3vOgfMBcInRDUZ5nmKRiSQvireUCpHiFGGCKD8Cg_3jeL_n-BScxbhEiAvG0ADYyZcNixaqUq3a6COsHNQqamUsDNYFv7BBNb4qYWxjY9dwW4UPXy7g1jfvB0XZwFr5EOGM4WTGEBt1iaa_MMfn4MSpVbQXP3MIXm8nL-P7ZPp09zAeTRNNCeGJI0hbnVlBOcpVISzRQmjnjKGFYXPDCUWIoMwWc57NmWOGaGNczjjWCHNDh-Cqz61D9bmxsZHLahO6alGSLOMFY1nBOhXvVTpUMXYdZB38WoVWYiR3SOWOltyRkx1SiWWPtDOS3uir-pD8r-n6D9Pj8-SXTNbG0W_oLITk</recordid><startdate>20180601</startdate><enddate>20180601</enddate><creator>Roy, Ranendra</creator><creator>Mandal, Bijan Kumar</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20180601</creationdate><title>Exergy analysis of cascade refrigeration system working with refrigerant pairs R41-R404A and R41-R161</title><author>Roy, Ranendra ; Mandal, Bijan Kumar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Circuits</topic><topic>Comparative studies</topic><topic>Evaporators</topic><topic>Exergy</topic><topic>High temperature</topic><topic>Parameters</topic><topic>Refrigerants</topic><topic>Refrigeration</topic><topic>Thermophysical properties</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Roy, Ranendra</creatorcontrib><creatorcontrib>Mandal, Bijan Kumar</creatorcontrib><collection>IOP Publishing</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>IOP conference series. Materials Science and Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Roy, Ranendra</au><au>Mandal, Bijan Kumar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Exergy analysis of cascade refrigeration system working with refrigerant pairs R41-R404A and R41-R161</atitle><jtitle>IOP conference series. Materials Science and Engineering</jtitle><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><date>2018-06-01</date><risdate>2018</risdate><volume>377</volume><issue>1</issue><spage>12036</spage><pages>12036-</pages><issn>1757-8981</issn><eissn>1757-899X</eissn><abstract>In this paper, a comparative study of vapour cascade refrigeration system performance with R41 - R161 and R41 - R404A refrigerant couples have been presented to find out best suited refrigerant between R161 and R404A in the high temperature circuit. A mathematical model has been developed using the basic equations of refrigeration system for the calculation of basic performance parameters energetically and exergetically. Few parameters have been assumed to carry out the simulation. Simulated results show that R41 - R161 gives better results than R41 - R404A in all aspects, i.e. compressor power, COP, exergy destruction and exergetic efficiency wise. Exergetic analysis reveals that maximum and minimum losses for R41 - R161 occurs in the high temperature circuit compressor and evaporator respectively. Therefore, R161 can be a promising refrigerant to R404A due to its better thermophysical and environmental properties.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1757-899X/377/1/012036</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1757-8981 |
ispartof | IOP conference series. Materials Science and Engineering, 2018-06, Vol.377 (1), p.12036 |
issn | 1757-8981 1757-899X |
language | eng |
recordid | cdi_proquest_journals_2556944594 |
source | Publicly Available Content Database; Free Full-Text Journals in Chemistry |
subjects | Circuits Comparative studies Evaporators Exergy High temperature Parameters Refrigerants Refrigeration Thermophysical properties |
title | Exergy analysis of cascade refrigeration system working with refrigerant pairs R41-R404A and R41-R161 |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T20%3A24%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Exergy%20analysis%20of%20cascade%20refrigeration%20system%20working%20with%20refrigerant%20pairs%20R41-R404A%20and%20R41-R161&rft.jtitle=IOP%20conference%20series.%20Materials%20Science%20and%20Engineering&rft.au=Roy,%20Ranendra&rft.date=2018-06-01&rft.volume=377&rft.issue=1&rft.spage=12036&rft.pages=12036-&rft.issn=1757-8981&rft.eissn=1757-899X&rft_id=info:doi/10.1088/1757-899X/377/1/012036&rft_dat=%3Cproquest_iop_j%3E2556944594%3C/proquest_iop_j%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3226-f20cec5e73608a97e2c77cffdd39d4bd62300205e9b65b4f4d2cddf8461c016d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2556944594&rft_id=info:pmid/&rfr_iscdi=true |