Real-time PCR, the best approaches for rapid testing for Mycobacterium chimaera detection in heater cooler units and extracorporeal membrane oxygenation
According to recent investigations, the risk of M. chimaera contamination of heater-cooler units (HCUs) has reached global proportions. Our aim was to field evaluate a protocol for early detection of M. chimaera contamination. We assessed the presence of viable M. chimaera in 395 water samples obtai...
Saved in:
Published in: | Perfusion 2021-09, Vol.36 (6), p.626-629 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853 |
---|---|
cites | cdi_FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853 |
container_end_page | 629 |
container_issue | 6 |
container_start_page | 626 |
container_title | Perfusion |
container_volume | 36 |
creator | Ditommaso, Savina Giacomuzzi, Monica Memoli, Gabriele Zotti, Carla M |
description | According to recent investigations, the risk of M. chimaera contamination of heater-cooler units (HCUs) has reached global proportions. Our aim was to field evaluate a protocol for early detection of M. chimaera contamination. We assessed the presence of viable M. chimaera in 395 water samples obtained from 48 devices (HCUs and extracorporeal membrane oxygenation) by Real Time PCR. Thirty devices were NTM positive, of which 14 were contaminated with M. chimaera. The most frequently contaminated devices were the Stockert 3T. Noteworthy, Stockert 3T devices were positive for M. chimaera. In conclusion, this study introduces novel PMA-PCR designed to specifically detect M. chimaera in HCUs and ECMO devices; this method can replace the culture method for continuous microbiological surveillance. The timely detection of M. chimaera contamination can then be used to improve effective management of the devices. |
doi_str_mv | 10.1177/0267659120963878 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2561868258</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_0267659120963878</sage_id><sourcerecordid>2561868258</sourcerecordid><originalsourceid>FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853</originalsourceid><addsrcrecordid>eNp1UF1LwzAUDaLgnL77GPDVatKmSfoowy-YKEPBt5Kmt2vG2tQkg-2f-HNNnSAIPh245-NyDkLnlFxRKsQ1SbngeUFTUvBMCnmAJpQJkVBK3w_RZKSTkT9GJ96vCCGMsWyCPheg1kkwHeCX2eIShxZwBT5gNQzOKt2Cx4112KnB1DhExvTL78vTTttK6QDObDqsW9MpcArXEEAHY3tsetyCijzW1q4jbHoTPFZ9jWEbnNLWDdbF97iDrnKqB2y3uyX0arSfoqNGrT2c_eAUvd3dvs4ekvnz_ePsZp7ojBQhyVilFeMFr2TVNFTIRvGC5amuatpkvKi0rHMgPBUEMkJELoA1tNA0S4HlMs-m6GKfG-t-bGK_cmU3ro8vyzTnVHKZ5jKqyF6lnfXeQVMOLhZ2u5KScty__Lt_tCR7i1dL-A39V_8Ft3KHrA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2561868258</pqid></control><display><type>article</type><title>Real-time PCR, the best approaches for rapid testing for Mycobacterium chimaera detection in heater cooler units and extracorporeal membrane oxygenation</title><source>Sage Journals Online</source><creator>Ditommaso, Savina ; Giacomuzzi, Monica ; Memoli, Gabriele ; Zotti, Carla M</creator><creatorcontrib>Ditommaso, Savina ; Giacomuzzi, Monica ; Memoli, Gabriele ; Zotti, Carla M</creatorcontrib><description>According to recent investigations, the risk of M. chimaera contamination of heater-cooler units (HCUs) has reached global proportions. Our aim was to field evaluate a protocol for early detection of M. chimaera contamination. We assessed the presence of viable M. chimaera in 395 water samples obtained from 48 devices (HCUs and extracorporeal membrane oxygenation) by Real Time PCR. Thirty devices were NTM positive, of which 14 were contaminated with M. chimaera. The most frequently contaminated devices were the Stockert 3T. Noteworthy, Stockert 3T devices were positive for M. chimaera. In conclusion, this study introduces novel PMA-PCR designed to specifically detect M. chimaera in HCUs and ECMO devices; this method can replace the culture method for continuous microbiological surveillance. The timely detection of M. chimaera contamination can then be used to improve effective management of the devices.</description><identifier>ISSN: 0267-6591</identifier><identifier>EISSN: 1477-111X</identifier><identifier>DOI: 10.1177/0267659120963878</identifier><language>eng</language><publisher>London, England: SAGE Publications</publisher><subject>Contamination ; Devices ; Extracorporeal membrane oxygenation ; Membranes ; Oxygenation ; Real time ; Water analysis ; Water sampling</subject><ispartof>Perfusion, 2021-09, Vol.36 (6), p.626-629</ispartof><rights>The Author(s) 2021</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853</citedby><cites>FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853</cites><orcidid>0000-0003-1590-9009 ; 0000-0002-7211-079X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925,79364</link.rule.ids></links><search><creatorcontrib>Ditommaso, Savina</creatorcontrib><creatorcontrib>Giacomuzzi, Monica</creatorcontrib><creatorcontrib>Memoli, Gabriele</creatorcontrib><creatorcontrib>Zotti, Carla M</creatorcontrib><title>Real-time PCR, the best approaches for rapid testing for Mycobacterium chimaera detection in heater cooler units and extracorporeal membrane oxygenation</title><title>Perfusion</title><addtitle>Perfusion</addtitle><description>According to recent investigations, the risk of M. chimaera contamination of heater-cooler units (HCUs) has reached global proportions. Our aim was to field evaluate a protocol for early detection of M. chimaera contamination. We assessed the presence of viable M. chimaera in 395 water samples obtained from 48 devices (HCUs and extracorporeal membrane oxygenation) by Real Time PCR. Thirty devices were NTM positive, of which 14 were contaminated with M. chimaera. The most frequently contaminated devices were the Stockert 3T. Noteworthy, Stockert 3T devices were positive for M. chimaera. In conclusion, this study introduces novel PMA-PCR designed to specifically detect M. chimaera in HCUs and ECMO devices; this method can replace the culture method for continuous microbiological surveillance. The timely detection of M. chimaera contamination can then be used to improve effective management of the devices.</description><subject>Contamination</subject><subject>Devices</subject><subject>Extracorporeal membrane oxygenation</subject><subject>Membranes</subject><subject>Oxygenation</subject><subject>Real time</subject><subject>Water analysis</subject><subject>Water sampling</subject><issn>0267-6591</issn><issn>1477-111X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1UF1LwzAUDaLgnL77GPDVatKmSfoowy-YKEPBt5Kmt2vG2tQkg-2f-HNNnSAIPh245-NyDkLnlFxRKsQ1SbngeUFTUvBMCnmAJpQJkVBK3w_RZKSTkT9GJ96vCCGMsWyCPheg1kkwHeCX2eIShxZwBT5gNQzOKt2Cx4112KnB1DhExvTL78vTTttK6QDObDqsW9MpcArXEEAHY3tsetyCijzW1q4jbHoTPFZ9jWEbnNLWDdbF97iDrnKqB2y3uyX0arSfoqNGrT2c_eAUvd3dvs4ekvnz_ePsZp7ojBQhyVilFeMFr2TVNFTIRvGC5amuatpkvKi0rHMgPBUEMkJELoA1tNA0S4HlMs-m6GKfG-t-bGK_cmU3ro8vyzTnVHKZ5jKqyF6lnfXeQVMOLhZ2u5KScty__Lt_tCR7i1dL-A39V_8Ft3KHrA</recordid><startdate>202109</startdate><enddate>202109</enddate><creator>Ditommaso, Savina</creator><creator>Giacomuzzi, Monica</creator><creator>Memoli, Gabriele</creator><creator>Zotti, Carla M</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TK</scope><scope>7U7</scope><scope>C1K</scope><scope>K9.</scope><scope>NAPCQ</scope><orcidid>https://orcid.org/0000-0003-1590-9009</orcidid><orcidid>https://orcid.org/0000-0002-7211-079X</orcidid></search><sort><creationdate>202109</creationdate><title>Real-time PCR, the best approaches for rapid testing for Mycobacterium chimaera detection in heater cooler units and extracorporeal membrane oxygenation</title><author>Ditommaso, Savina ; Giacomuzzi, Monica ; Memoli, Gabriele ; Zotti, Carla M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Contamination</topic><topic>Devices</topic><topic>Extracorporeal membrane oxygenation</topic><topic>Membranes</topic><topic>Oxygenation</topic><topic>Real time</topic><topic>Water analysis</topic><topic>Water sampling</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ditommaso, Savina</creatorcontrib><creatorcontrib>Giacomuzzi, Monica</creatorcontrib><creatorcontrib>Memoli, Gabriele</creatorcontrib><creatorcontrib>Zotti, Carla M</creatorcontrib><collection>CrossRef</collection><collection>Neurosciences Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Premium</collection><jtitle>Perfusion</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ditommaso, Savina</au><au>Giacomuzzi, Monica</au><au>Memoli, Gabriele</au><au>Zotti, Carla M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Real-time PCR, the best approaches for rapid testing for Mycobacterium chimaera detection in heater cooler units and extracorporeal membrane oxygenation</atitle><jtitle>Perfusion</jtitle><addtitle>Perfusion</addtitle><date>2021-09</date><risdate>2021</risdate><volume>36</volume><issue>6</issue><spage>626</spage><epage>629</epage><pages>626-629</pages><issn>0267-6591</issn><eissn>1477-111X</eissn><abstract>According to recent investigations, the risk of M. chimaera contamination of heater-cooler units (HCUs) has reached global proportions. Our aim was to field evaluate a protocol for early detection of M. chimaera contamination. We assessed the presence of viable M. chimaera in 395 water samples obtained from 48 devices (HCUs and extracorporeal membrane oxygenation) by Real Time PCR. Thirty devices were NTM positive, of which 14 were contaminated with M. chimaera. The most frequently contaminated devices were the Stockert 3T. Noteworthy, Stockert 3T devices were positive for M. chimaera. In conclusion, this study introduces novel PMA-PCR designed to specifically detect M. chimaera in HCUs and ECMO devices; this method can replace the culture method for continuous microbiological surveillance. The timely detection of M. chimaera contamination can then be used to improve effective management of the devices.</abstract><cop>London, England</cop><pub>SAGE Publications</pub><doi>10.1177/0267659120963878</doi><tpages>4</tpages><orcidid>https://orcid.org/0000-0003-1590-9009</orcidid><orcidid>https://orcid.org/0000-0002-7211-079X</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0267-6591 |
ispartof | Perfusion, 2021-09, Vol.36 (6), p.626-629 |
issn | 0267-6591 1477-111X |
language | eng |
recordid | cdi_proquest_journals_2561868258 |
source | Sage Journals Online |
subjects | Contamination Devices Extracorporeal membrane oxygenation Membranes Oxygenation Real time Water analysis Water sampling |
title | Real-time PCR, the best approaches for rapid testing for Mycobacterium chimaera detection in heater cooler units and extracorporeal membrane oxygenation |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T13%3A12%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Real-time%20PCR,%20the%20best%20approaches%20for%20rapid%20testing%20for%20Mycobacterium%20chimaera%20detection%20in%20heater%20cooler%20units%20and%20extracorporeal%20membrane%20oxygenation&rft.jtitle=Perfusion&rft.au=Ditommaso,%20Savina&rft.date=2021-09&rft.volume=36&rft.issue=6&rft.spage=626&rft.epage=629&rft.pages=626-629&rft.issn=0267-6591&rft.eissn=1477-111X&rft_id=info:doi/10.1177/0267659120963878&rft_dat=%3Cproquest_cross%3E2561868258%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c309t-34bca4696b8bff178fa69452cbd1f369bc8d5e06270e300757e4f19c132e45853%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2561868258&rft_id=info:pmid/&rft_sage_id=10.1177_0267659120963878&rfr_iscdi=true |