Loading…
Heat load to the cryogenic system in the 1000 m class superconducting DC power transmission system
Long-term circulation and load cycle tests of the cooling of the 1000 m class superconducting DC power transmission system in Ishikari, Japan were performed to measure the heat load delivered to and the power consumption of the cryogenic system. The average heat load and power consumption during the...
Saved in:
Published in: | Journal of physics. Conference series 2019-09, Vol.1293 (1), p.12071 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Long-term circulation and load cycle tests of the cooling of the 1000 m class superconducting DC power transmission system in Ishikari, Japan were performed to measure the heat load delivered to and the power consumption of the cryogenic system. The average heat load and power consumption during these tests was about 2.5 and 120 kW, respectively. To increase the efficiency of superconducting power transmission systems, the selection and composition of constituent devices of the cooling system should be optimized. |
---|---|
ISSN: | 1742-6588 1742-6596 |
DOI: | 10.1088/1742-6596/1293/1/012071 |