Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material...

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. Conference series 2018-03, Vol.975 (1), p.12047
Main Authors: Costa, J J S, Cardoso, D D, Gavazza, S, Oliveira, C L, Morales, R K, Amorim, A S, Balthar, M C V, Oliveira, L S R
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens.
ISSN:1742-6588
1742-6596
DOI:10.1088/1742-6596/975/1/012047