Ground Vibration Attenuation Measurement using Triaxial and Single Axis Accelerometers

Peak Particle Velocity is one of the important term to show the level of the vibration amplitude especially traveling wave by distance. Vibration measurement using triaxial accelerometer is needed to obtain accurate value of PPV however limited by the size and the available channel of the data acqui...

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. Conference series 2018-04, Vol.995 (1), p.12113
Main Authors: Mohammad, A H, Yusoff, N A, Madun, A, Tajudin, S A A, Zahari, M N H, Chik, T N T, Rahman, N A, Annuar, Y M N
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Peak Particle Velocity is one of the important term to show the level of the vibration amplitude especially traveling wave by distance. Vibration measurement using triaxial accelerometer is needed to obtain accurate value of PPV however limited by the size and the available channel of the data acquisition module for detailed measurement. In this paper, an attempt to estimate accurate PPV has been made by using only a triaxial accelerometer together with multiple single axis accelerometer for the ground vibration measurement. A field test was conducted on soft ground using nine single axis accelerometers and a triaxial accelerometer installed at nine receiver location R1 to R9. Based from the obtained result, the method shows convincing similarity between actual PPV with the calculated PPV with error ratio 0.97. With the design method, vibration measurement equipment size can be reduced with fewer channel required.
ISSN:1742-6588
1742-6596
DOI:10.1088/1742-6596/995/1/012113