Loading…
Study of Natural Convection Passive Cooling System for Nuclear Reactors
Fukushima nuclear reactor accident occurred due to the reactor cooling pumps and followed by all emergencies cooling systems could not work. Therefore, the system which has a passive safety system that rely on natural laws such as natural convection passive cooling system. In natural convection, the...
Saved in:
Published in: | Journal of physics. Conference series 2017-07, Vol.877 (1), p.12047 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c408t-8bf27d6d7fb938a4307a2ecf29cdae493b47e1b136ee61464bfd0f7963eb72b23 |
---|---|
cites | |
container_end_page | |
container_issue | 1 |
container_start_page | 12047 |
container_title | Journal of physics. Conference series |
container_volume | 877 |
creator | Abdillah, Habibi Saputra, Geby Novitrian Permana, Sidik |
description | Fukushima nuclear reactor accident occurred due to the reactor cooling pumps and followed by all emergencies cooling systems could not work. Therefore, the system which has a passive safety system that rely on natural laws such as natural convection passive cooling system. In natural convection, the cooling material can flow due to the different density of the material due to the temperature difference. To analyze such investigation, a simple apparatus was set up and explains the study of natural convection in a vertical closed-loop system. It was set up that, in the closed loop, there is a heater at the bottom which is representing heat source system from the reactor core and cooler at the top which is showing the cooling system performance in room temperature to make a temperature difference for convection process. The study aims to find some loop configurations and some natural convection performances that can produce an optimum flow of cooling process. The study was done and focused on experimental approach and simulation. The obtained results are showing and analyzing in temperature profile data and the speed of coolant flow at some point on the closed-loop system. |
doi_str_mv | 10.1088/1742-6596/877/1/012047 |
format | article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_journals_2574605031</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2574605031</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-8bf27d6d7fb938a4307a2ecf29cdae493b47e1b136ee61464bfd0f7963eb72b23</originalsourceid><addsrcrecordid>eNqFkN9LwzAQgIMoOKf_ggR88qE2v5akj1J0KmMOp88hbRPp6JqatIP992ZUFEHwXu64--4OPgAuMbrBSMoUC0YSPst4KoVIcYowQUwcgcn34Pi7lvIUnIWwQYjGEBMwX_dDtYfOwqXuB68bmLt2Z8q-di1c6RDqnYkt19TtO1zvQ2-20DoPl0PZGO3hi9Fl73w4BydWN8FcfOUpeLu_e80fksXz_DG_XSQlQ7JPZGGJqHglbJFRqRlFQhNTWpKVlTYsowUTBheYcmM4ZpwVtkJWZJyaQpCC0Cm4Gu923n0MJvRq4wbfxpeKzATjaIYojhQfqdK7ELyxqvP1Vvu9wkgdpKmDD3Vwo6I0hdUoLS5ej4u1634uP63y9S9OdZWNLPmD_efBJzHze5k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2574605031</pqid></control><display><type>article</type><title>Study of Natural Convection Passive Cooling System for Nuclear Reactors</title><source>Publicly Available Content Database</source><source>Free Full-Text Journals in Chemistry</source><creator>Abdillah, Habibi ; Saputra, Geby ; Novitrian ; Permana, Sidik</creator><creatorcontrib>Abdillah, Habibi ; Saputra, Geby ; Novitrian ; Permana, Sidik</creatorcontrib><description>Fukushima nuclear reactor accident occurred due to the reactor cooling pumps and followed by all emergencies cooling systems could not work. Therefore, the system which has a passive safety system that rely on natural laws such as natural convection passive cooling system. In natural convection, the cooling material can flow due to the different density of the material due to the temperature difference. To analyze such investigation, a simple apparatus was set up and explains the study of natural convection in a vertical closed-loop system. It was set up that, in the closed loop, there is a heater at the bottom which is representing heat source system from the reactor core and cooler at the top which is showing the cooling system performance in room temperature to make a temperature difference for convection process. The study aims to find some loop configurations and some natural convection performances that can produce an optimum flow of cooling process. The study was done and focused on experimental approach and simulation. The obtained results are showing and analyzing in temperature profile data and the speed of coolant flow at some point on the closed-loop system.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/877/1/012047</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Closed loop systems ; Closed loops ; Convection cooling ; Cooling ; Cooling systems ; Feedback control ; Flow-density-speed relationships ; Free convection ; Nuclear accidents ; Nuclear reactors ; Nuclear safety ; Physics ; Room temperature ; Temperature gradients ; Temperature profiles</subject><ispartof>Journal of physics. Conference series, 2017-07, Vol.877 (1), p.12047</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>2017. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-8bf27d6d7fb938a4307a2ecf29cdae493b47e1b136ee61464bfd0f7963eb72b23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2574605031?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Abdillah, Habibi</creatorcontrib><creatorcontrib>Saputra, Geby</creatorcontrib><creatorcontrib>Novitrian</creatorcontrib><creatorcontrib>Permana, Sidik</creatorcontrib><title>Study of Natural Convection Passive Cooling System for Nuclear Reactors</title><title>Journal of physics. Conference series</title><addtitle>J. Phys.: Conf. Ser</addtitle><description>Fukushima nuclear reactor accident occurred due to the reactor cooling pumps and followed by all emergencies cooling systems could not work. Therefore, the system which has a passive safety system that rely on natural laws such as natural convection passive cooling system. In natural convection, the cooling material can flow due to the different density of the material due to the temperature difference. To analyze such investigation, a simple apparatus was set up and explains the study of natural convection in a vertical closed-loop system. It was set up that, in the closed loop, there is a heater at the bottom which is representing heat source system from the reactor core and cooler at the top which is showing the cooling system performance in room temperature to make a temperature difference for convection process. The study aims to find some loop configurations and some natural convection performances that can produce an optimum flow of cooling process. The study was done and focused on experimental approach and simulation. The obtained results are showing and analyzing in temperature profile data and the speed of coolant flow at some point on the closed-loop system.</description><subject>Closed loop systems</subject><subject>Closed loops</subject><subject>Convection cooling</subject><subject>Cooling</subject><subject>Cooling systems</subject><subject>Feedback control</subject><subject>Flow-density-speed relationships</subject><subject>Free convection</subject><subject>Nuclear accidents</subject><subject>Nuclear reactors</subject><subject>Nuclear safety</subject><subject>Physics</subject><subject>Room temperature</subject><subject>Temperature gradients</subject><subject>Temperature profiles</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqFkN9LwzAQgIMoOKf_ggR88qE2v5akj1J0KmMOp88hbRPp6JqatIP992ZUFEHwXu64--4OPgAuMbrBSMoUC0YSPst4KoVIcYowQUwcgcn34Pi7lvIUnIWwQYjGEBMwX_dDtYfOwqXuB68bmLt2Z8q-di1c6RDqnYkt19TtO1zvQ2-20DoPl0PZGO3hi9Fl73w4BydWN8FcfOUpeLu_e80fksXz_DG_XSQlQ7JPZGGJqHglbJFRqRlFQhNTWpKVlTYsowUTBheYcmM4ZpwVtkJWZJyaQpCC0Cm4Gu923n0MJvRq4wbfxpeKzATjaIYojhQfqdK7ELyxqvP1Vvu9wkgdpKmDD3Vwo6I0hdUoLS5ej4u1634uP63y9S9OdZWNLPmD_efBJzHze5k</recordid><startdate>20170701</startdate><enddate>20170701</enddate><creator>Abdillah, Habibi</creator><creator>Saputra, Geby</creator><creator>Novitrian</creator><creator>Permana, Sidik</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20170701</creationdate><title>Study of Natural Convection Passive Cooling System for Nuclear Reactors</title><author>Abdillah, Habibi ; Saputra, Geby ; Novitrian ; Permana, Sidik</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-8bf27d6d7fb938a4307a2ecf29cdae493b47e1b136ee61464bfd0f7963eb72b23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Closed loop systems</topic><topic>Closed loops</topic><topic>Convection cooling</topic><topic>Cooling</topic><topic>Cooling systems</topic><topic>Feedback control</topic><topic>Flow-density-speed relationships</topic><topic>Free convection</topic><topic>Nuclear accidents</topic><topic>Nuclear reactors</topic><topic>Nuclear safety</topic><topic>Physics</topic><topic>Room temperature</topic><topic>Temperature gradients</topic><topic>Temperature profiles</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Abdillah, Habibi</creatorcontrib><creatorcontrib>Saputra, Geby</creatorcontrib><creatorcontrib>Novitrian</creatorcontrib><creatorcontrib>Permana, Sidik</creatorcontrib><collection>Open Access: IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest advanced technologies & aerospace journals</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Abdillah, Habibi</au><au>Saputra, Geby</au><au>Novitrian</au><au>Permana, Sidik</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study of Natural Convection Passive Cooling System for Nuclear Reactors</atitle><jtitle>Journal of physics. Conference series</jtitle><addtitle>J. Phys.: Conf. Ser</addtitle><date>2017-07-01</date><risdate>2017</risdate><volume>877</volume><issue>1</issue><spage>12047</spage><pages>12047-</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>Fukushima nuclear reactor accident occurred due to the reactor cooling pumps and followed by all emergencies cooling systems could not work. Therefore, the system which has a passive safety system that rely on natural laws such as natural convection passive cooling system. In natural convection, the cooling material can flow due to the different density of the material due to the temperature difference. To analyze such investigation, a simple apparatus was set up and explains the study of natural convection in a vertical closed-loop system. It was set up that, in the closed loop, there is a heater at the bottom which is representing heat source system from the reactor core and cooler at the top which is showing the cooling system performance in room temperature to make a temperature difference for convection process. The study aims to find some loop configurations and some natural convection performances that can produce an optimum flow of cooling process. The study was done and focused on experimental approach and simulation. The obtained results are showing and analyzing in temperature profile data and the speed of coolant flow at some point on the closed-loop system.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/877/1/012047</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1742-6588 |
ispartof | Journal of physics. Conference series, 2017-07, Vol.877 (1), p.12047 |
issn | 1742-6588 1742-6596 |
language | eng |
recordid | cdi_proquest_journals_2574605031 |
source | Publicly Available Content Database; Free Full-Text Journals in Chemistry |
subjects | Closed loop systems Closed loops Convection cooling Cooling Cooling systems Feedback control Flow-density-speed relationships Free convection Nuclear accidents Nuclear reactors Nuclear safety Physics Room temperature Temperature gradients Temperature profiles |
title | Study of Natural Convection Passive Cooling System for Nuclear Reactors |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T04%3A10%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20of%20Natural%20Convection%20Passive%20Cooling%20System%20for%20Nuclear%20Reactors&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Abdillah,%20Habibi&rft.date=2017-07-01&rft.volume=877&rft.issue=1&rft.spage=12047&rft.pages=12047-&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/877/1/012047&rft_dat=%3Cproquest_iop_j%3E2574605031%3C/proquest_iop_j%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c408t-8bf27d6d7fb938a4307a2ecf29cdae493b47e1b136ee61464bfd0f7963eb72b23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2574605031&rft_id=info:pmid/&rfr_iscdi=true |