Loading…

An apparatus for the charge-to-mass and charge-to-diameter measurements on powders

This paper presents design and evaluation of a simple tool for assessing of electric charge levels on powders. The testing device uses a stackable Faraday cup arrangement for measurement of charges on size fractions of the powder under investigation. The powder is pneumatically transported through t...

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. Conference series 2008-12, Vol.142 (1), p.012080
Main Author: Noras, Maciej A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3
cites cdi_FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3
container_end_page
container_issue 1
container_start_page 012080
container_title Journal of physics. Conference series
container_volume 142
creator Noras, Maciej A
description This paper presents design and evaluation of a simple tool for assessing of electric charge levels on powders. The testing device uses a stackable Faraday cup arrangement for measurement of charges on size fractions of the powder under investigation. The powder is pneumatically transported through the Faraday cups column. The cups utilize specially designed sieves for separation of the powder particles by size. Additionally, the sieving membrane in the topmost cup is acoustically vibrated to help with the powder separation process
doi_str_mv 10.1088/1742-6596/142/1/012080
format article
fullrecord <record><control><sourceid>proquest_iop_p</sourceid><recordid>TN_cdi_proquest_journals_2580548360</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2580548360</sourcerecordid><originalsourceid>FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3</originalsourceid><addsrcrecordid>eNqNkE1LxDAQhoMouK7-BQl4jk3Sph_HZfELFgTRc0iaibuLbWKSIv57Wyqyhz04c5hh5n1n4EHomtFbRus6Y1XBSSmaMmMFz1hGGac1PUGLv8XpQX-OLmLcU5qPUS3Qy6rHynsVVBoiti7gtAXcblV4B5Ic6VSMWPXmYGR2qoMEAXeg4hCggz5F7Hrs3ZeBEC_RmVUfEa5-6xK93d-9rh_J5vnhab3akDYvWCJgS9boguUCmkppC8ZWTFvDmR1TA29bq9vC1FqoQgvLtShzULpueWOMNvkS3cx3fXCfA8Qk924I_fhSclFTUdR5SUdVOava4GIMYKUPu06Fb8monPjJCY2c0MiRn2Ry5jca2WzcOf9_DzniOaqV3tj8Bx5NgSk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2580548360</pqid></control><display><type>article</type><title>An apparatus for the charge-to-mass and charge-to-diameter measurements on powders</title><source>Publicly Available Content Database</source><source>Full-Text Journals in Chemistry (Open access)</source><creator>Noras, Maciej A</creator><creatorcontrib>Noras, Maciej A</creatorcontrib><description>This paper presents design and evaluation of a simple tool for assessing of electric charge levels on powders. The testing device uses a stackable Faraday cup arrangement for measurement of charges on size fractions of the powder under investigation. The powder is pneumatically transported through the Faraday cups column. The cups utilize specially designed sieves for separation of the powder particles by size. Additionally, the sieving membrane in the topmost cup is acoustically vibrated to help with the powder separation process</description><identifier>ISSN: 1742-6596</identifier><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/142/1/012080</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Cups ; Diameters ; Physics ; Separation</subject><ispartof>Journal of physics. Conference series, 2008-12, Vol.142 (1), p.012080</ispartof><rights>Copyright IOP Publishing Dec 2008</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3</citedby><cites>FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2580548360?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Noras, Maciej A</creatorcontrib><title>An apparatus for the charge-to-mass and charge-to-diameter measurements on powders</title><title>Journal of physics. Conference series</title><description>This paper presents design and evaluation of a simple tool for assessing of electric charge levels on powders. The testing device uses a stackable Faraday cup arrangement for measurement of charges on size fractions of the powder under investigation. The powder is pneumatically transported through the Faraday cups column. The cups utilize specially designed sieves for separation of the powder particles by size. Additionally, the sieving membrane in the topmost cup is acoustically vibrated to help with the powder separation process</description><subject>Cups</subject><subject>Diameters</subject><subject>Physics</subject><subject>Separation</subject><issn>1742-6596</issn><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNkE1LxDAQhoMouK7-BQl4jk3Sph_HZfELFgTRc0iaibuLbWKSIv57Wyqyhz04c5hh5n1n4EHomtFbRus6Y1XBSSmaMmMFz1hGGac1PUGLv8XpQX-OLmLcU5qPUS3Qy6rHynsVVBoiti7gtAXcblV4B5Ic6VSMWPXmYGR2qoMEAXeg4hCggz5F7Hrs3ZeBEC_RmVUfEa5-6xK93d-9rh_J5vnhab3akDYvWCJgS9boguUCmkppC8ZWTFvDmR1TA29bq9vC1FqoQgvLtShzULpueWOMNvkS3cx3fXCfA8Qk924I_fhSclFTUdR5SUdVOava4GIMYKUPu06Fb8monPjJCY2c0MiRn2Ry5jca2WzcOf9_DzniOaqV3tj8Bx5NgSk</recordid><startdate>20081201</startdate><enddate>20081201</enddate><creator>Noras, Maciej A</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20081201</creationdate><title>An apparatus for the charge-to-mass and charge-to-diameter measurements on powders</title><author>Noras, Maciej A</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>Cups</topic><topic>Diameters</topic><topic>Physics</topic><topic>Separation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Noras, Maciej A</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest advanced technologies &amp; aerospace journals</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Noras, Maciej A</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An apparatus for the charge-to-mass and charge-to-diameter measurements on powders</atitle><jtitle>Journal of physics. Conference series</jtitle><date>2008-12-01</date><risdate>2008</risdate><volume>142</volume><issue>1</issue><spage>012080</spage><pages>012080-</pages><issn>1742-6596</issn><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>This paper presents design and evaluation of a simple tool for assessing of electric charge levels on powders. The testing device uses a stackable Faraday cup arrangement for measurement of charges on size fractions of the powder under investigation. The powder is pneumatically transported through the Faraday cups column. The cups utilize specially designed sieves for separation of the powder particles by size. Additionally, the sieving membrane in the topmost cup is acoustically vibrated to help with the powder separation process</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/142/1/012080</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1742-6596
ispartof Journal of physics. Conference series, 2008-12, Vol.142 (1), p.012080
issn 1742-6596
1742-6588
1742-6596
language eng
recordid cdi_proquest_journals_2580548360
source Publicly Available Content Database; Full-Text Journals in Chemistry (Open access)
subjects Cups
Diameters
Physics
Separation
title An apparatus for the charge-to-mass and charge-to-diameter measurements on powders
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T18%3A35%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_p&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20apparatus%20for%20the%20charge-to-mass%20and%20charge-to-diameter%20measurements%20on%20powders&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Noras,%20Maciej%20A&rft.date=2008-12-01&rft.volume=142&rft.issue=1&rft.spage=012080&rft.pages=012080-&rft.issn=1742-6596&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/142/1/012080&rft_dat=%3Cproquest_iop_p%3E2580548360%3C/proquest_iop_p%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c341t-ef619b4135e97abfedf71bfd21f1f1be2ccfbc4d8b5a4b5f2b563eab8c29ddbd3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2580548360&rft_id=info:pmid/&rfr_iscdi=true