Characterisation of hydrogen assisted cracking in modified 9Cr-1Mo steel welds using acoustic emission non destructive technique

This study aims a systematic experimental investigation using acoustic emission (AE) non-destructive technique for online monitoring of hydrogen assisted cracking (HAC) in modified 9Cr-1Mo steel (P91 steel) welds during Gap-Bead on Plate (G-BOP) and implant tests. Welds made without preheating, with...

Full description

Saved in:
Bibliographic Details
Published in:Nondestructive testing and evaluation 2021-11, Vol.36 (6), p.692-708
Main Authors: Haneef, T.K., Chakraborty, Gopa, Rejeesh, R., Mukhopadhyay, C.K., Albert, S. K.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63
cites cdi_FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63
container_end_page 708
container_issue 6
container_start_page 692
container_title Nondestructive testing and evaluation
container_volume 36
creator Haneef, T.K.
Chakraborty, Gopa
Rejeesh, R.
Mukhopadhyay, C.K.
Albert, S. K.
description This study aims a systematic experimental investigation using acoustic emission (AE) non-destructive technique for online monitoring of hydrogen assisted cracking (HAC) in modified 9Cr-1Mo steel (P91 steel) welds during Gap-Bead on Plate (G-BOP) and implant tests. Welds made without preheating, with different preheating and combined pre and post heating were tested using G-BOP test. AE results of G-BOP tests have shown that time duration in which HAC active varies with temperature of preheating and combined pre and post heating. Reduction of AE activity in welds made with pre and post heating compared to those only made with preheating revealed a beneficial effect of the former in reducing HAC. In the case of implant tests, crack initiation and propagation are identified for different applied loads from the AE analysis. An attempt has been made to compare HAC during G-BOP tests and implant tests using AE frequency analysis. The dominant frequency of AE signals characteristic of HAC has been identified. This study shows the potential of using AE frequency analysis for online monitoring of hydrogen assisted cracking (HAC) in welds.
doi_str_mv 10.1080/10589759.2021.1889547
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2597363213</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2597363213</sourcerecordid><originalsourceid>FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63</originalsourceid><addsrcrecordid>eNp9kMtKBDEQRRtR8PkJQsB1j3l0OumdMvgCxY2uQyapONGeRJO0Mjs_3QyjWxdFFcWpe6nbNKcEzwiW-JxgLgfBhxnFlMyIlAPvxE5zQDohWtoLslvnyrQbaL85zPkVV5ILedB8z5c6aVMg-ayLjwFFh5Zrm-ILBKRz9rmARaYybz68IB_QKlrvfF0O89SSh4gqASP6gtFmNOUNpU2ccvEGwcpXiaoaalnIJU2m-E9ABcwy-I8Jjps9p8cMJ7_9qHm-vnqa37b3jzd388v71jAmS31jQTiXBjPpOkZAioETzgSRXWfcYMD2mjoNQ4_pAjrbgaMUuHOMEqsXPTtqzra67ylW21zUa5xSqJaK8kGwvoKsUnxLmRRzTuDUe_IrndaKYLUJW_2FrTZhq9-w693F9s4HF9NKf8U0WlX0eozJJR2Mz4r9L_EDGJuImQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2597363213</pqid></control><display><type>article</type><title>Characterisation of hydrogen assisted cracking in modified 9Cr-1Mo steel welds using acoustic emission non destructive technique</title><source>Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Science and Technology Collection (Reading list)</source><creator>Haneef, T.K. ; Chakraborty, Gopa ; Rejeesh, R. ; Mukhopadhyay, C.K. ; Albert, S. K.</creator><creatorcontrib>Haneef, T.K. ; Chakraborty, Gopa ; Rejeesh, R. ; Mukhopadhyay, C.K. ; Albert, S. K.</creatorcontrib><description>This study aims a systematic experimental investigation using acoustic emission (AE) non-destructive technique for online monitoring of hydrogen assisted cracking (HAC) in modified 9Cr-1Mo steel (P91 steel) welds during Gap-Bead on Plate (G-BOP) and implant tests. Welds made without preheating, with different preheating and combined pre and post heating were tested using G-BOP test. AE results of G-BOP tests have shown that time duration in which HAC active varies with temperature of preheating and combined pre and post heating. Reduction of AE activity in welds made with pre and post heating compared to those only made with preheating revealed a beneficial effect of the former in reducing HAC. In the case of implant tests, crack initiation and propagation are identified for different applied loads from the AE analysis. An attempt has been made to compare HAC during G-BOP tests and implant tests using AE frequency analysis. The dominant frequency of AE signals characteristic of HAC has been identified. This study shows the potential of using AE frequency analysis for online monitoring of hydrogen assisted cracking (HAC) in welds.</description><identifier>ISSN: 1058-9759</identifier><identifier>EISSN: 1477-2671</identifier><identifier>DOI: 10.1080/10589759.2021.1889547</identifier><language>eng</language><publisher>Abingdon: Taylor &amp; Francis</publisher><subject>Acoustic emission ; Chromium molybdenum steels ; Crack initiation ; Crack propagation ; Emission analysis ; Environmentally assisted cracking ; Frequency analysis ; gap-bead on plate test and implant test ; Heating ; Hydrogen ; hydrogen assisted cracking ; modified 9Cr-1Mo steel ; Monitoring ; Nondestructive testing</subject><ispartof>Nondestructive testing and evaluation, 2021-11, Vol.36 (6), p.692-708</ispartof><rights>2021 Informa UK Limited, trading as Taylor &amp; Francis Group 2021</rights><rights>2021 Informa UK Limited, trading as Taylor &amp; Francis Group</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63</citedby><cites>FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Haneef, T.K.</creatorcontrib><creatorcontrib>Chakraborty, Gopa</creatorcontrib><creatorcontrib>Rejeesh, R.</creatorcontrib><creatorcontrib>Mukhopadhyay, C.K.</creatorcontrib><creatorcontrib>Albert, S. K.</creatorcontrib><title>Characterisation of hydrogen assisted cracking in modified 9Cr-1Mo steel welds using acoustic emission non destructive technique</title><title>Nondestructive testing and evaluation</title><description>This study aims a systematic experimental investigation using acoustic emission (AE) non-destructive technique for online monitoring of hydrogen assisted cracking (HAC) in modified 9Cr-1Mo steel (P91 steel) welds during Gap-Bead on Plate (G-BOP) and implant tests. Welds made without preheating, with different preheating and combined pre and post heating were tested using G-BOP test. AE results of G-BOP tests have shown that time duration in which HAC active varies with temperature of preheating and combined pre and post heating. Reduction of AE activity in welds made with pre and post heating compared to those only made with preheating revealed a beneficial effect of the former in reducing HAC. In the case of implant tests, crack initiation and propagation are identified for different applied loads from the AE analysis. An attempt has been made to compare HAC during G-BOP tests and implant tests using AE frequency analysis. The dominant frequency of AE signals characteristic of HAC has been identified. This study shows the potential of using AE frequency analysis for online monitoring of hydrogen assisted cracking (HAC) in welds.</description><subject>Acoustic emission</subject><subject>Chromium molybdenum steels</subject><subject>Crack initiation</subject><subject>Crack propagation</subject><subject>Emission analysis</subject><subject>Environmentally assisted cracking</subject><subject>Frequency analysis</subject><subject>gap-bead on plate test and implant test</subject><subject>Heating</subject><subject>Hydrogen</subject><subject>hydrogen assisted cracking</subject><subject>modified 9Cr-1Mo steel</subject><subject>Monitoring</subject><subject>Nondestructive testing</subject><issn>1058-9759</issn><issn>1477-2671</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kMtKBDEQRRtR8PkJQsB1j3l0OumdMvgCxY2uQyapONGeRJO0Mjs_3QyjWxdFFcWpe6nbNKcEzwiW-JxgLgfBhxnFlMyIlAPvxE5zQDohWtoLslvnyrQbaL85zPkVV5ILedB8z5c6aVMg-ayLjwFFh5Zrm-ILBKRz9rmARaYybz68IB_QKlrvfF0O89SSh4gqASP6gtFmNOUNpU2ccvEGwcpXiaoaalnIJU2m-E9ABcwy-I8Jjps9p8cMJ7_9qHm-vnqa37b3jzd388v71jAmS31jQTiXBjPpOkZAioETzgSRXWfcYMD2mjoNQ4_pAjrbgaMUuHOMEqsXPTtqzra67ylW21zUa5xSqJaK8kGwvoKsUnxLmRRzTuDUe_IrndaKYLUJW_2FrTZhq9-w693F9s4HF9NKf8U0WlX0eozJJR2Mz4r9L_EDGJuImQ</recordid><startdate>20211102</startdate><enddate>20211102</enddate><creator>Haneef, T.K.</creator><creator>Chakraborty, Gopa</creator><creator>Rejeesh, R.</creator><creator>Mukhopadhyay, C.K.</creator><creator>Albert, S. K.</creator><general>Taylor &amp; Francis</general><general>Taylor &amp; Francis Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope></search><sort><creationdate>20211102</creationdate><title>Characterisation of hydrogen assisted cracking in modified 9Cr-1Mo steel welds using acoustic emission non destructive technique</title><author>Haneef, T.K. ; Chakraborty, Gopa ; Rejeesh, R. ; Mukhopadhyay, C.K. ; Albert, S. K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Acoustic emission</topic><topic>Chromium molybdenum steels</topic><topic>Crack initiation</topic><topic>Crack propagation</topic><topic>Emission analysis</topic><topic>Environmentally assisted cracking</topic><topic>Frequency analysis</topic><topic>gap-bead on plate test and implant test</topic><topic>Heating</topic><topic>Hydrogen</topic><topic>hydrogen assisted cracking</topic><topic>modified 9Cr-1Mo steel</topic><topic>Monitoring</topic><topic>Nondestructive testing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Haneef, T.K.</creatorcontrib><creatorcontrib>Chakraborty, Gopa</creatorcontrib><creatorcontrib>Rejeesh, R.</creatorcontrib><creatorcontrib>Mukhopadhyay, C.K.</creatorcontrib><creatorcontrib>Albert, S. K.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><jtitle>Nondestructive testing and evaluation</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Haneef, T.K.</au><au>Chakraborty, Gopa</au><au>Rejeesh, R.</au><au>Mukhopadhyay, C.K.</au><au>Albert, S. K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Characterisation of hydrogen assisted cracking in modified 9Cr-1Mo steel welds using acoustic emission non destructive technique</atitle><jtitle>Nondestructive testing and evaluation</jtitle><date>2021-11-02</date><risdate>2021</risdate><volume>36</volume><issue>6</issue><spage>692</spage><epage>708</epage><pages>692-708</pages><issn>1058-9759</issn><eissn>1477-2671</eissn><abstract>This study aims a systematic experimental investigation using acoustic emission (AE) non-destructive technique for online monitoring of hydrogen assisted cracking (HAC) in modified 9Cr-1Mo steel (P91 steel) welds during Gap-Bead on Plate (G-BOP) and implant tests. Welds made without preheating, with different preheating and combined pre and post heating were tested using G-BOP test. AE results of G-BOP tests have shown that time duration in which HAC active varies with temperature of preheating and combined pre and post heating. Reduction of AE activity in welds made with pre and post heating compared to those only made with preheating revealed a beneficial effect of the former in reducing HAC. In the case of implant tests, crack initiation and propagation are identified for different applied loads from the AE analysis. An attempt has been made to compare HAC during G-BOP tests and implant tests using AE frequency analysis. The dominant frequency of AE signals characteristic of HAC has been identified. This study shows the potential of using AE frequency analysis for online monitoring of hydrogen assisted cracking (HAC) in welds.</abstract><cop>Abingdon</cop><pub>Taylor &amp; Francis</pub><doi>10.1080/10589759.2021.1889547</doi><tpages>17</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1058-9759
ispartof Nondestructive testing and evaluation, 2021-11, Vol.36 (6), p.692-708
issn 1058-9759
1477-2671
language eng
recordid cdi_proquest_journals_2597363213
source Taylor and Francis:Jisc Collections:Taylor and Francis Read and Publish Agreement 2024-2025:Science and Technology Collection (Reading list)
subjects Acoustic emission
Chromium molybdenum steels
Crack initiation
Crack propagation
Emission analysis
Environmentally assisted cracking
Frequency analysis
gap-bead on plate test and implant test
Heating
Hydrogen
hydrogen assisted cracking
modified 9Cr-1Mo steel
Monitoring
Nondestructive testing
title Characterisation of hydrogen assisted cracking in modified 9Cr-1Mo steel welds using acoustic emission non destructive technique
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T07%3A14%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Characterisation%20of%20hydrogen%20assisted%20cracking%20in%20modified%209Cr-1Mo%20steel%20welds%20using%20acoustic%20emission%20non%20destructive%20technique&rft.jtitle=Nondestructive%20testing%20and%20evaluation&rft.au=Haneef,%20T.K.&rft.date=2021-11-02&rft.volume=36&rft.issue=6&rft.spage=692&rft.epage=708&rft.pages=692-708&rft.issn=1058-9759&rft.eissn=1477-2671&rft_id=info:doi/10.1080/10589759.2021.1889547&rft_dat=%3Cproquest_cross%3E2597363213%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c338t-26b1558c038f431e879515371844cf9ced6a2fae9602be4d4ef22e5ff321dab63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2597363213&rft_id=info:pmid/&rfr_iscdi=true