An air insulated linear pulse transformer for electrodischarge technology

A linear pulse transformer with air insulation at atmospheric pressure was created and tested under both constant resistance and non linear loads. The maximum power of the transformer output pulse reached ∼500 MW at a matched load with a charge voltage 50 kV. The transformer transferred ∼60% of the...

Full description

Saved in:
Bibliographic Details
Published in:Journal of instrumentation 2021-12, Vol.16 (12), p.P12006
Main Authors: Zherlitsyn, A.A., Alexeenko, V.M., Kondratiev, S.S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A linear pulse transformer with air insulation at atmospheric pressure was created and tested under both constant resistance and non linear loads. The maximum power of the transformer output pulse reached ∼500 MW at a matched load with a charge voltage 50 kV. The transformer transferred ∼60% of the stored energy to the load over a characteristic time of about 1 μs. The scalability the generator was studied by connecting two identical transformers in series which gave a power output of ∼850 MW with doubled output voltage and reduced current. The frequency mode of operation was studied using one and two transformers with a charge voltage of 50 kV and a load that was, close to matched. In both cases, the power maximum and jitter showed no significant changes at any of the frequencies tested (up to 5 Hz). These results mean that the use of this generator can be recommended for a wide field of applications due to its scalability and low internal impedance.
ISSN:1748-0221
1748-0221
DOI:10.1088/1748-0221/16/12/P12006