A Precise Current Detection Method Using a Single Shunt and FET Rds(on) of a Low-Voltage Three-Phase Inverter

In this study, a low-voltage three-phase inverter was used alongside a shunt resistor to measure the current. However, it is known that this type of inverter and shunt resistor system has a region where the measurement of current is impossible due to structural limitations. As a result, many studies...

Full description

Saved in:
Bibliographic Details
Published in:Electronics (Basel) 2022-01, Vol.11 (1), p.9
Main Authors: Hwang, Jae-Yeob, Park, Ji-Hwan, Choi, Ji-Ho, Uhm, Jun-Ik, Lee, Geun-Ho, Lim, Hee-Sun
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3
cites cdi_FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3
container_end_page
container_issue 1
container_start_page 9
container_title Electronics (Basel)
container_volume 11
creator Hwang, Jae-Yeob
Park, Ji-Hwan
Choi, Ji-Ho
Uhm, Jun-Ik
Lee, Geun-Ho
Lim, Hee-Sun
description In this study, a low-voltage three-phase inverter was used alongside a shunt resistor to measure the current. However, it is known that this type of inverter and shunt resistor system has a region where the measurement of current is impossible due to structural limitations. As a result, many studies have focused on this region through the use of additional algorithms. Most studies measured current by forcibly adjusting the PWM duty in order to measure the current at the region where it could not be sensed. However, unfortunately, the total harmonic distortion (THD) increases in the current due to PWM adjustment. This causes an increase in torque ripple and inverter control instability. Therefore, in this paper, current was measured using the Rds(on) value between the drain source resistor when MOSFET was turned on and the Kalman filter in a low-voltage three-phase inverter with a single shunt. Additionally, the value was verified via comparison with the values achieved when a Hall-type current sensor and single shunt were used. As a result, this study confirmed that the inverter with a single shunt performs the same as a Hall-type sensor at the region where current cannot be detected.
doi_str_mv 10.3390/electronics11010009
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2618216518</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2618216518</sourcerecordid><originalsourceid>FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3</originalsourceid><addsrcrecordid>eNptkDtPwzAYRS0EElXpL2CxxAJDwI-kiceqvCoVUdGWNXLsL02q1C62A-Lf46oMDEz3DkfnShehS0puORfkDjpQwVnTKk8poYQQcYIGjOQiEUyw0z_9HI2835IDQnnByQDtJnjhQLUe8LR3DkzA9xCisLUGv0BorMZr35oNlngZowO8bPpISaPx48MKv2l_bc0NtnUk5vYrebddkBvAq8YBJItGRvXMfIIL4C7QWS07D6PfHKJ1dEyfk_nr02w6mSeKMxYSBnUloCAVYxmtoBBpmokx1VrlKqdKapKnStMsI5LXnHFRpYIC54rlslaZ5kN0dfTunf3owYdya3tn4mTJxrRgdJzRIlL8SClnvXdQl3vX7qT7LikpD9eW_1zLfwDCd24s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2618216518</pqid></control><display><type>article</type><title>A Precise Current Detection Method Using a Single Shunt and FET Rds(on) of a Low-Voltage Three-Phase Inverter</title><source>Publicly Available Content Database</source><creator>Hwang, Jae-Yeob ; Park, Ji-Hwan ; Choi, Ji-Ho ; Uhm, Jun-Ik ; Lee, Geun-Ho ; Lim, Hee-Sun</creator><creatorcontrib>Hwang, Jae-Yeob ; Park, Ji-Hwan ; Choi, Ji-Ho ; Uhm, Jun-Ik ; Lee, Geun-Ho ; Lim, Hee-Sun</creatorcontrib><description>In this study, a low-voltage three-phase inverter was used alongside a shunt resistor to measure the current. However, it is known that this type of inverter and shunt resistor system has a region where the measurement of current is impossible due to structural limitations. As a result, many studies have focused on this region through the use of additional algorithms. Most studies measured current by forcibly adjusting the PWM duty in order to measure the current at the region where it could not be sensed. However, unfortunately, the total harmonic distortion (THD) increases in the current due to PWM adjustment. This causes an increase in torque ripple and inverter control instability. Therefore, in this paper, current was measured using the Rds(on) value between the drain source resistor when MOSFET was turned on and the Kalman filter in a low-voltage three-phase inverter with a single shunt. Additionally, the value was verified via comparison with the values achieved when a Hall-type current sensor and single shunt were used. As a result, this study confirmed that the inverter with a single shunt performs the same as a Hall-type sensor at the region where current cannot be detected.</description><identifier>ISSN: 2079-9292</identifier><identifier>EISSN: 2079-9292</identifier><identifier>DOI: 10.3390/electronics11010009</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Algorithms ; Control stability ; Electric potential ; Fault diagnosis ; Harmonic distortion ; Inverters ; Kalman filters ; MOSFETs ; Noise ; Sensors ; Voltage</subject><ispartof>Electronics (Basel), 2022-01, Vol.11 (1), p.9</ispartof><rights>2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3</citedby><cites>FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3</cites><orcidid>0000-0003-4513-2149 ; 0000-0003-3570-5046 ; 0000-0001-7380-0859</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2618216518/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2618216518?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,74998</link.rule.ids></links><search><creatorcontrib>Hwang, Jae-Yeob</creatorcontrib><creatorcontrib>Park, Ji-Hwan</creatorcontrib><creatorcontrib>Choi, Ji-Ho</creatorcontrib><creatorcontrib>Uhm, Jun-Ik</creatorcontrib><creatorcontrib>Lee, Geun-Ho</creatorcontrib><creatorcontrib>Lim, Hee-Sun</creatorcontrib><title>A Precise Current Detection Method Using a Single Shunt and FET Rds(on) of a Low-Voltage Three-Phase Inverter</title><title>Electronics (Basel)</title><description>In this study, a low-voltage three-phase inverter was used alongside a shunt resistor to measure the current. However, it is known that this type of inverter and shunt resistor system has a region where the measurement of current is impossible due to structural limitations. As a result, many studies have focused on this region through the use of additional algorithms. Most studies measured current by forcibly adjusting the PWM duty in order to measure the current at the region where it could not be sensed. However, unfortunately, the total harmonic distortion (THD) increases in the current due to PWM adjustment. This causes an increase in torque ripple and inverter control instability. Therefore, in this paper, current was measured using the Rds(on) value between the drain source resistor when MOSFET was turned on and the Kalman filter in a low-voltage three-phase inverter with a single shunt. Additionally, the value was verified via comparison with the values achieved when a Hall-type current sensor and single shunt were used. As a result, this study confirmed that the inverter with a single shunt performs the same as a Hall-type sensor at the region where current cannot be detected.</description><subject>Algorithms</subject><subject>Control stability</subject><subject>Electric potential</subject><subject>Fault diagnosis</subject><subject>Harmonic distortion</subject><subject>Inverters</subject><subject>Kalman filters</subject><subject>MOSFETs</subject><subject>Noise</subject><subject>Sensors</subject><subject>Voltage</subject><issn>2079-9292</issn><issn>2079-9292</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNptkDtPwzAYRS0EElXpL2CxxAJDwI-kiceqvCoVUdGWNXLsL02q1C62A-Lf46oMDEz3DkfnShehS0puORfkDjpQwVnTKk8poYQQcYIGjOQiEUyw0z_9HI2835IDQnnByQDtJnjhQLUe8LR3DkzA9xCisLUGv0BorMZr35oNlngZowO8bPpISaPx48MKv2l_bc0NtnUk5vYrebddkBvAq8YBJItGRvXMfIIL4C7QWS07D6PfHKJ1dEyfk_nr02w6mSeKMxYSBnUloCAVYxmtoBBpmokx1VrlKqdKapKnStMsI5LXnHFRpYIC54rlslaZ5kN0dfTunf3owYdya3tn4mTJxrRgdJzRIlL8SClnvXdQl3vX7qT7LikpD9eW_1zLfwDCd24s</recordid><startdate>20220101</startdate><enddate>20220101</enddate><creator>Hwang, Jae-Yeob</creator><creator>Park, Ji-Hwan</creator><creator>Choi, Ji-Ho</creator><creator>Uhm, Jun-Ik</creator><creator>Lee, Geun-Ho</creator><creator>Lim, Hee-Sun</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SP</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0003-4513-2149</orcidid><orcidid>https://orcid.org/0000-0003-3570-5046</orcidid><orcidid>https://orcid.org/0000-0001-7380-0859</orcidid></search><sort><creationdate>20220101</creationdate><title>A Precise Current Detection Method Using a Single Shunt and FET Rds(on) of a Low-Voltage Three-Phase Inverter</title><author>Hwang, Jae-Yeob ; Park, Ji-Hwan ; Choi, Ji-Ho ; Uhm, Jun-Ik ; Lee, Geun-Ho ; Lim, Hee-Sun</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Algorithms</topic><topic>Control stability</topic><topic>Electric potential</topic><topic>Fault diagnosis</topic><topic>Harmonic distortion</topic><topic>Inverters</topic><topic>Kalman filters</topic><topic>MOSFETs</topic><topic>Noise</topic><topic>Sensors</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hwang, Jae-Yeob</creatorcontrib><creatorcontrib>Park, Ji-Hwan</creatorcontrib><creatorcontrib>Choi, Ji-Ho</creatorcontrib><creatorcontrib>Uhm, Jun-Ik</creatorcontrib><creatorcontrib>Lee, Geun-Ho</creatorcontrib><creatorcontrib>Lim, Hee-Sun</creatorcontrib><collection>CrossRef</collection><collection>Electronics &amp; Communications Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>Advanced Technologies &amp; Aerospace Database</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Electronics (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hwang, Jae-Yeob</au><au>Park, Ji-Hwan</au><au>Choi, Ji-Ho</au><au>Uhm, Jun-Ik</au><au>Lee, Geun-Ho</au><au>Lim, Hee-Sun</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Precise Current Detection Method Using a Single Shunt and FET Rds(on) of a Low-Voltage Three-Phase Inverter</atitle><jtitle>Electronics (Basel)</jtitle><date>2022-01-01</date><risdate>2022</risdate><volume>11</volume><issue>1</issue><spage>9</spage><pages>9-</pages><issn>2079-9292</issn><eissn>2079-9292</eissn><abstract>In this study, a low-voltage three-phase inverter was used alongside a shunt resistor to measure the current. However, it is known that this type of inverter and shunt resistor system has a region where the measurement of current is impossible due to structural limitations. As a result, many studies have focused on this region through the use of additional algorithms. Most studies measured current by forcibly adjusting the PWM duty in order to measure the current at the region where it could not be sensed. However, unfortunately, the total harmonic distortion (THD) increases in the current due to PWM adjustment. This causes an increase in torque ripple and inverter control instability. Therefore, in this paper, current was measured using the Rds(on) value between the drain source resistor when MOSFET was turned on and the Kalman filter in a low-voltage three-phase inverter with a single shunt. Additionally, the value was verified via comparison with the values achieved when a Hall-type current sensor and single shunt were used. As a result, this study confirmed that the inverter with a single shunt performs the same as a Hall-type sensor at the region where current cannot be detected.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/electronics11010009</doi><orcidid>https://orcid.org/0000-0003-4513-2149</orcidid><orcidid>https://orcid.org/0000-0003-3570-5046</orcidid><orcidid>https://orcid.org/0000-0001-7380-0859</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2079-9292
ispartof Electronics (Basel), 2022-01, Vol.11 (1), p.9
issn 2079-9292
2079-9292
language eng
recordid cdi_proquest_journals_2618216518
source Publicly Available Content Database
subjects Algorithms
Control stability
Electric potential
Fault diagnosis
Harmonic distortion
Inverters
Kalman filters
MOSFETs
Noise
Sensors
Voltage
title A Precise Current Detection Method Using a Single Shunt and FET Rds(on) of a Low-Voltage Three-Phase Inverter
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T02%3A50%3A09IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Precise%20Current%20Detection%20Method%20Using%20a%20Single%20Shunt%20and%20FET%20Rds(on)%20of%20a%20Low-Voltage%20Three-Phase%20Inverter&rft.jtitle=Electronics%20(Basel)&rft.au=Hwang,%20Jae-Yeob&rft.date=2022-01-01&rft.volume=11&rft.issue=1&rft.spage=9&rft.pages=9-&rft.issn=2079-9292&rft.eissn=2079-9292&rft_id=info:doi/10.3390/electronics11010009&rft_dat=%3Cproquest_cross%3E2618216518%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c322t-2efb9e80b2251be89445961ddc7c71cad074cd1550a3f3239b491e33c27afc5d3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2618216518&rft_id=info:pmid/&rfr_iscdi=true