Micro-Particle Image Velocimetry for imaging flows in passive microfluidic mixers
The micro-Particle Image Velocimetry (micro-PIV) was used to measure flow velocities in micro-channels in two passive micromixers: a microfluidic Venturi mixer and a microfluidic spiral mixer, both preceded by standard “Y” micromixers. The micro-devices were made of borosilicate glass, with micro-en...
Saved in:
Published in: | Metrology and Measurement systems 2018-01, Vol.25 (3), p.441 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The micro-Particle Image Velocimetry (micro-PIV) was used to measure flow velocities in micro-channels in two passive micromixers: a microfluidic Venturi mixer and a microfluidic spiral mixer, both preceded by standard “Y” micromixers. The micro-devices were made of borosilicate glass, with micro-engineering techniques dedicated to micro-PIV measurements. The obtained velocity profiles show differences in the flow structure in both cases. The micro-PIV enables understanding the micro-flow phenomena and can help to increase reproducibility of micromixers in mass production. |
---|---|
ISSN: | 2080-9050 2300-1941 |
DOI: | 10.24425/123890 |