Loading…

Deep learning based automated detection of intraretinal cystoid fluid

The diversified ocular disorders in which cystoid macular edema (CME) occurs, are strongly associated with the vision loss. Optical coherence tomography (OCT) scans that allow screening of the retina, contain artifacts including blur‐edges, speckle noise, and so forth, which create difficulty in ide...

Full description

Saved in:
Bibliographic Details
Published in:International journal of imaging systems and technology 2022-05, Vol.32 (3), p.902-917
Main Authors: Ahmed, Zeeshan, Panhwar, Shahbaz Qamar, Baqai, Attiya, Umrani, Fahim Aziz, Ahmed, Munawar, Khan, Arbaaz
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423
cites cdi_FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423
container_end_page 917
container_issue 3
container_start_page 902
container_title International journal of imaging systems and technology
container_volume 32
creator Ahmed, Zeeshan
Panhwar, Shahbaz Qamar
Baqai, Attiya
Umrani, Fahim Aziz
Ahmed, Munawar
Khan, Arbaaz
description The diversified ocular disorders in which cystoid macular edema (CME) occurs, are strongly associated with the vision loss. Optical coherence tomography (OCT) scans that allow screening of the retina, contain artifacts including blur‐edges, speckle noise, and so forth, which create difficulty in identifying retinal fluid. In this work, major image preprocessing techniques such as minimum filtering, block‐matching and 3D filtering, and Richardson–Lucy deconvolution method are applied to minimize noise and other degradation effects from OCT scans, ensured by maintaining image quality assessment scores, that is, blind‐less image spatial quality evaluator and sharpness estimation score. Furthermore, this work develops an automated method based on deep learning (DL) to detect the presence and progression of retinal fluid, that is, CME and its quantification. Specifically, U‐net model with efficient tuning of hyperparameters is proposed to obtain optimal results. The algorithm's performance is evaluated for accurate identification of fluid localization in the case of diabetic macular edema (DME), having CME regions, and compared against the manual segmentation of fluid by experts, which are highly correlated. This enhanced DL method achieves better performance than the algorithms previously reported. The proposed algorithm is evaluated on several performance metrics during training and reports the best score of 99.81, 0.50, 83.34, 86.56, 80.89, and 99.48% for model accuracy, binary cross‐entropy loss, Dice coefficient (DC), precision, recall, and area under the ROC‐curve, respectively. Additionally, fourfold cross‐validation technique is also applied and an average DC score of 84.00% is obtained. This approach can be helpful to prevent vision loss.
doi_str_mv 10.1002/ima.22662
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2657886238</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2657886238</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423</originalsourceid><addsrcrecordid>eNp1kMtKAzEUhoMoWKsL3yDgysW0uU-yLPVWqLjRdchtJGU6U5MM0rd36rh1cy7w_YfDB8AtRguMEFnGvVkQIgQ5AzOMlKxO5RzMkFSqUozXl-Aq5x1CGHPEZ-DxIYQDbINJXew-oTU5eGiG0u9NGScfSnAl9h3sGxi7kkwKJXamhe6YSx89bNoh-mtw0Zg2h5u_PgcfT4_v65dq-_a8Wa-2lSOqJpWXtWg4C9RLayxRtAlcKelY4AwLbIXjjgjvEOOUeecUoZJiiazF1NaM0Dm4m-4eUv81hFz0rh_S-E7WRPBaSnFKzMH9RLnU55xCow9p9JKOGiN9sqTHTf9aGtnlxH7HNhz_B_XmdTUlfgAB6Wgv</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2657886238</pqid></control><display><type>article</type><title>Deep learning based automated detection of intraretinal cystoid fluid</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Ahmed, Zeeshan ; Panhwar, Shahbaz Qamar ; Baqai, Attiya ; Umrani, Fahim Aziz ; Ahmed, Munawar ; Khan, Arbaaz</creator><creatorcontrib>Ahmed, Zeeshan ; Panhwar, Shahbaz Qamar ; Baqai, Attiya ; Umrani, Fahim Aziz ; Ahmed, Munawar ; Khan, Arbaaz</creatorcontrib><description>The diversified ocular disorders in which cystoid macular edema (CME) occurs, are strongly associated with the vision loss. Optical coherence tomography (OCT) scans that allow screening of the retina, contain artifacts including blur‐edges, speckle noise, and so forth, which create difficulty in identifying retinal fluid. In this work, major image preprocessing techniques such as minimum filtering, block‐matching and 3D filtering, and Richardson–Lucy deconvolution method are applied to minimize noise and other degradation effects from OCT scans, ensured by maintaining image quality assessment scores, that is, blind‐less image spatial quality evaluator and sharpness estimation score. Furthermore, this work develops an automated method based on deep learning (DL) to detect the presence and progression of retinal fluid, that is, CME and its quantification. Specifically, U‐net model with efficient tuning of hyperparameters is proposed to obtain optimal results. The algorithm's performance is evaluated for accurate identification of fluid localization in the case of diabetic macular edema (DME), having CME regions, and compared against the manual segmentation of fluid by experts, which are highly correlated. This enhanced DL method achieves better performance than the algorithms previously reported. The proposed algorithm is evaluated on several performance metrics during training and reports the best score of 99.81, 0.50, 83.34, 86.56, 80.89, and 99.48% for model accuracy, binary cross‐entropy loss, Dice coefficient (DC), precision, recall, and area under the ROC‐curve, respectively. Additionally, fourfold cross‐validation technique is also applied and an average DC score of 84.00% is obtained. This approach can be helpful to prevent vision loss.</description><identifier>ISSN: 0899-9457</identifier><identifier>EISSN: 1098-1098</identifier><identifier>DOI: 10.1002/ima.22662</identifier><language>eng</language><publisher>Hoboken, USA: John Wiley &amp; Sons, Inc</publisher><subject>Algorithms ; artificial intelligence (AI) ; Automation ; cystoid macular edema (CME) ; Deep learning ; deep learning (DL) ; diabetic macular edema (DME) ; Edema ; Filtration ; image processing ; Image quality ; Image segmentation ; Machine learning ; Model accuracy ; Optical Coherence Tomography ; optical coherence tomography (OCT) ; Performance evaluation ; Performance measurement ; Quality assessment ; Vision</subject><ispartof>International journal of imaging systems and technology, 2022-05, Vol.32 (3), p.902-917</ispartof><rights>2021 Wiley Periodicals LLC.</rights><rights>2022 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423</citedby><cites>FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423</cites><orcidid>0000-0002-3736-3484 ; 0000-0003-3766-396X ; 0000-0003-0158-5445</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27898,27899</link.rule.ids></links><search><creatorcontrib>Ahmed, Zeeshan</creatorcontrib><creatorcontrib>Panhwar, Shahbaz Qamar</creatorcontrib><creatorcontrib>Baqai, Attiya</creatorcontrib><creatorcontrib>Umrani, Fahim Aziz</creatorcontrib><creatorcontrib>Ahmed, Munawar</creatorcontrib><creatorcontrib>Khan, Arbaaz</creatorcontrib><title>Deep learning based automated detection of intraretinal cystoid fluid</title><title>International journal of imaging systems and technology</title><description>The diversified ocular disorders in which cystoid macular edema (CME) occurs, are strongly associated with the vision loss. Optical coherence tomography (OCT) scans that allow screening of the retina, contain artifacts including blur‐edges, speckle noise, and so forth, which create difficulty in identifying retinal fluid. In this work, major image preprocessing techniques such as minimum filtering, block‐matching and 3D filtering, and Richardson–Lucy deconvolution method are applied to minimize noise and other degradation effects from OCT scans, ensured by maintaining image quality assessment scores, that is, blind‐less image spatial quality evaluator and sharpness estimation score. Furthermore, this work develops an automated method based on deep learning (DL) to detect the presence and progression of retinal fluid, that is, CME and its quantification. Specifically, U‐net model with efficient tuning of hyperparameters is proposed to obtain optimal results. The algorithm's performance is evaluated for accurate identification of fluid localization in the case of diabetic macular edema (DME), having CME regions, and compared against the manual segmentation of fluid by experts, which are highly correlated. This enhanced DL method achieves better performance than the algorithms previously reported. The proposed algorithm is evaluated on several performance metrics during training and reports the best score of 99.81, 0.50, 83.34, 86.56, 80.89, and 99.48% for model accuracy, binary cross‐entropy loss, Dice coefficient (DC), precision, recall, and area under the ROC‐curve, respectively. Additionally, fourfold cross‐validation technique is also applied and an average DC score of 84.00% is obtained. This approach can be helpful to prevent vision loss.</description><subject>Algorithms</subject><subject>artificial intelligence (AI)</subject><subject>Automation</subject><subject>cystoid macular edema (CME)</subject><subject>Deep learning</subject><subject>deep learning (DL)</subject><subject>diabetic macular edema (DME)</subject><subject>Edema</subject><subject>Filtration</subject><subject>image processing</subject><subject>Image quality</subject><subject>Image segmentation</subject><subject>Machine learning</subject><subject>Model accuracy</subject><subject>Optical Coherence Tomography</subject><subject>optical coherence tomography (OCT)</subject><subject>Performance evaluation</subject><subject>Performance measurement</subject><subject>Quality assessment</subject><subject>Vision</subject><issn>0899-9457</issn><issn>1098-1098</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp1kMtKAzEUhoMoWKsL3yDgysW0uU-yLPVWqLjRdchtJGU6U5MM0rd36rh1cy7w_YfDB8AtRguMEFnGvVkQIgQ5AzOMlKxO5RzMkFSqUozXl-Aq5x1CGHPEZ-DxIYQDbINJXew-oTU5eGiG0u9NGScfSnAl9h3sGxi7kkwKJXamhe6YSx89bNoh-mtw0Zg2h5u_PgcfT4_v65dq-_a8Wa-2lSOqJpWXtWg4C9RLayxRtAlcKelY4AwLbIXjjgjvEOOUeecUoZJiiazF1NaM0Dm4m-4eUv81hFz0rh_S-E7WRPBaSnFKzMH9RLnU55xCow9p9JKOGiN9sqTHTf9aGtnlxH7HNhz_B_XmdTUlfgAB6Wgv</recordid><startdate>202205</startdate><enddate>202205</enddate><creator>Ahmed, Zeeshan</creator><creator>Panhwar, Shahbaz Qamar</creator><creator>Baqai, Attiya</creator><creator>Umrani, Fahim Aziz</creator><creator>Ahmed, Munawar</creator><creator>Khan, Arbaaz</creator><general>John Wiley &amp; Sons, Inc</general><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-3736-3484</orcidid><orcidid>https://orcid.org/0000-0003-3766-396X</orcidid><orcidid>https://orcid.org/0000-0003-0158-5445</orcidid></search><sort><creationdate>202205</creationdate><title>Deep learning based automated detection of intraretinal cystoid fluid</title><author>Ahmed, Zeeshan ; Panhwar, Shahbaz Qamar ; Baqai, Attiya ; Umrani, Fahim Aziz ; Ahmed, Munawar ; Khan, Arbaaz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Algorithms</topic><topic>artificial intelligence (AI)</topic><topic>Automation</topic><topic>cystoid macular edema (CME)</topic><topic>Deep learning</topic><topic>deep learning (DL)</topic><topic>diabetic macular edema (DME)</topic><topic>Edema</topic><topic>Filtration</topic><topic>image processing</topic><topic>Image quality</topic><topic>Image segmentation</topic><topic>Machine learning</topic><topic>Model accuracy</topic><topic>Optical Coherence Tomography</topic><topic>optical coherence tomography (OCT)</topic><topic>Performance evaluation</topic><topic>Performance measurement</topic><topic>Quality assessment</topic><topic>Vision</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ahmed, Zeeshan</creatorcontrib><creatorcontrib>Panhwar, Shahbaz Qamar</creatorcontrib><creatorcontrib>Baqai, Attiya</creatorcontrib><creatorcontrib>Umrani, Fahim Aziz</creatorcontrib><creatorcontrib>Ahmed, Munawar</creatorcontrib><creatorcontrib>Khan, Arbaaz</creatorcontrib><collection>CrossRef</collection><jtitle>International journal of imaging systems and technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ahmed, Zeeshan</au><au>Panhwar, Shahbaz Qamar</au><au>Baqai, Attiya</au><au>Umrani, Fahim Aziz</au><au>Ahmed, Munawar</au><au>Khan, Arbaaz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Deep learning based automated detection of intraretinal cystoid fluid</atitle><jtitle>International journal of imaging systems and technology</jtitle><date>2022-05</date><risdate>2022</risdate><volume>32</volume><issue>3</issue><spage>902</spage><epage>917</epage><pages>902-917</pages><issn>0899-9457</issn><eissn>1098-1098</eissn><abstract>The diversified ocular disorders in which cystoid macular edema (CME) occurs, are strongly associated with the vision loss. Optical coherence tomography (OCT) scans that allow screening of the retina, contain artifacts including blur‐edges, speckle noise, and so forth, which create difficulty in identifying retinal fluid. In this work, major image preprocessing techniques such as minimum filtering, block‐matching and 3D filtering, and Richardson–Lucy deconvolution method are applied to minimize noise and other degradation effects from OCT scans, ensured by maintaining image quality assessment scores, that is, blind‐less image spatial quality evaluator and sharpness estimation score. Furthermore, this work develops an automated method based on deep learning (DL) to detect the presence and progression of retinal fluid, that is, CME and its quantification. Specifically, U‐net model with efficient tuning of hyperparameters is proposed to obtain optimal results. The algorithm's performance is evaluated for accurate identification of fluid localization in the case of diabetic macular edema (DME), having CME regions, and compared against the manual segmentation of fluid by experts, which are highly correlated. This enhanced DL method achieves better performance than the algorithms previously reported. The proposed algorithm is evaluated on several performance metrics during training and reports the best score of 99.81, 0.50, 83.34, 86.56, 80.89, and 99.48% for model accuracy, binary cross‐entropy loss, Dice coefficient (DC), precision, recall, and area under the ROC‐curve, respectively. Additionally, fourfold cross‐validation technique is also applied and an average DC score of 84.00% is obtained. This approach can be helpful to prevent vision loss.</abstract><cop>Hoboken, USA</cop><pub>John Wiley &amp; Sons, Inc</pub><doi>10.1002/ima.22662</doi><tpages>16</tpages><orcidid>https://orcid.org/0000-0002-3736-3484</orcidid><orcidid>https://orcid.org/0000-0003-3766-396X</orcidid><orcidid>https://orcid.org/0000-0003-0158-5445</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0899-9457
ispartof International journal of imaging systems and technology, 2022-05, Vol.32 (3), p.902-917
issn 0899-9457
1098-1098
language eng
recordid cdi_proquest_journals_2657886238
source Wiley-Blackwell Read & Publish Collection
subjects Algorithms
artificial intelligence (AI)
Automation
cystoid macular edema (CME)
Deep learning
deep learning (DL)
diabetic macular edema (DME)
Edema
Filtration
image processing
Image quality
Image segmentation
Machine learning
Model accuracy
Optical Coherence Tomography
optical coherence tomography (OCT)
Performance evaluation
Performance measurement
Quality assessment
Vision
title Deep learning based automated detection of intraretinal cystoid fluid
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-25T23%3A34%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Deep%20learning%20based%20automated%20detection%20of%20intraretinal%20cystoid%20fluid&rft.jtitle=International%20journal%20of%20imaging%20systems%20and%20technology&rft.au=Ahmed,%20Zeeshan&rft.date=2022-05&rft.volume=32&rft.issue=3&rft.spage=902&rft.epage=917&rft.pages=902-917&rft.issn=0899-9457&rft.eissn=1098-1098&rft_id=info:doi/10.1002/ima.22662&rft_dat=%3Cproquest_cross%3E2657886238%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2972-d876f54e3d8bab293fe5998c4e54161b6c5c26dc04534dcc92383180bb13b7423%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2657886238&rft_id=info:pmid/&rfr_iscdi=true