Design and Simulation of Single‐Electrode Mode Triboelectric Nanogenerator‐Based Pulse Sensor for Healthcare Applications Using COMSOL Multiphysics

The advancement in triboelectric nanogenerator technology leads to numerous advantages in various fields, especially in biomedical and healthcare applications. Theoretical modeling and simulation of sensors is the initial step for an optimized cost‐effective real‐time sensor fabrication which reduce...

Full description

Saved in:
Bibliographic Details
Published in:Energy technology (Weinheim, Germany) Germany), 2022-05, Vol.10 (5), p.n/a
Main Authors: Mathew, Ammu Anna, Vivekanandan, Shanmugasundaram
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The advancement in triboelectric nanogenerator technology leads to numerous advantages in various fields, especially in biomedical and healthcare applications. Theoretical modeling and simulation of sensors is the initial step for an optimized cost‐effective real‐time sensor fabrication which reduces the wastage of materials and rapid prototyping, giving an expected sensor performance. Herein, a theoretical model of single‐electrode triboelectric nanogenerator is presented which finds its application in healthcare monitoring as a wearable flexible pulse sensor to measure the wrist pulse for disease diagnosis. The device optimization in terms of structure, material and output performance is done based on the said application. A brief study of the operating principle of the sensor along with the factors affecting the output is discussed in this work. The design is conceptually investigated considering the electrostatic shield effect from the contact electrode. The output performance variation concerning the plain and micro‐structured triboelectric surface is also determined in terms of open‐circuit voltage of ≈16.95 and ≈21.63 V, respectively, and also a short‐circuit charge of ≈181.81 and ≈196.57 pC, respectively. The superior output performance even for smaller wrist pulse displacement range can serve as a significant assistance for the rational plan of the device structure. The single‐electrode triboelectric nanogenerator wearable flexible pulse sensor optimization in terms of structure and material for pulse sensing application is done along with a study on the output performance improvement, thereby serving as a significant assistance for the rational plan of the device development even for a smaller range of displacement toward the wrist pulse measurement for disease diagnosis.
ISSN:2194-4288
2194-4296
DOI:10.1002/ente.202101130