Loading…
Potentiometric determination of copper(II) ions based on a porphyrin derivative
A novel poly(vinyl chloride; PVC) membrane‐based Cu(II)–selective sensor has been developed using synthesized 5,10,15,20‐tetrakis(4‐methoxycarbonylphenyl)porphyrin as an ionophore. The Cu(II)–selective sensor exhibits a Nernstian response for Cu(II) ion over a wide concentration range of 1.0 × 10−5...
Saved in:
Published in: | Journal of the Chinese Chemical Society (Taipei) 2022-07, Vol.69 (7), p.1060-1069 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3 |
---|---|
cites | cdi_FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3 |
container_end_page | 1069 |
container_issue | 7 |
container_start_page | 1060 |
container_title | Journal of the Chinese Chemical Society (Taipei) |
container_volume | 69 |
creator | Özbek, Oguz Isildak, Ömer |
description | A novel poly(vinyl chloride; PVC) membrane‐based Cu(II)–selective sensor has been developed using synthesized 5,10,15,20‐tetrakis(4‐methoxycarbonylphenyl)porphyrin as an ionophore. The Cu(II)–selective sensor exhibits a Nernstian response for Cu(II) ion over a wide concentration range of 1.0 × 10−5 to 1.0 × 10−1 mol L−1 with the slope of 27.0 ± 2.5 mV/decade, and a lower limit of detection of 1.88 × 10−6 mol L−1. The novel sensor shows good repeatability and high selectivity for Cu(II) ions over other mono‐, bi‐ and trivalent cations. The sensor potential response remains unaffected by pH in the range of 4.4–10.6 and exhibits a fast response time of less than 10s. Finally the developed Cu(II)–selective sensor has been successfully used as an indicator electrode in the potentiometric titration of Cu2+ against ethylenediaminetetraacetic acid and also in the determination of Cu(II) ion concentration in different water and beverage samples.
In this study, a novel potentiometric sensor was developed for the determination of Cu2+ ions. The developed sensor exhibits a linear response over a wide concentration range and has a very low detection limit. In addition, the copper(II)–selective sensor has advantages such as high selectivity, short response time, low cost, good repeatability, and stability. |
doi_str_mv | 10.1002/jccs.202200168 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2690952594</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2690952594</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3</originalsourceid><addsrcrecordid>eNqFkM1LAzEQxYMoWKtXzwEvetg6yW62m6MsflQKFdRzyM4mmNJu1mRb6X9vSkWPngbevN98PEIuGUwYAL9dIsYJB84BWFkdkRFnkmelKOQxGQGAzAqRl6fkLMYlQJFzIUdk8eIH0w3Or80QHNLWDCasXaeT1FFvKfq-N-F6NruhSYm00dG0NPU07X3oP3bBdYkKbpuQrTknJ1avorn4qWPy_nD_Vj9l88XjrL6bZ5izaZVhaxssNBrLp7ZEofe3gtSlrKABiRW0RWVbzaS12IhctFPODMs1Wtmg1fmYXB3m9sF_bkwc1NJvQpdWKl5KkCJ9VyTX5ODC4GMMxqo-uLUOO8VA7UNT-9DUb2gJkAfgy63M7h-3eq7r1z_2GzgNcig</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2690952594</pqid></control><display><type>article</type><title>Potentiometric determination of copper(II) ions based on a porphyrin derivative</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>Özbek, Oguz ; Isildak, Ömer</creator><creatorcontrib>Özbek, Oguz ; Isildak, Ömer</creatorcontrib><description>A novel poly(vinyl chloride; PVC) membrane‐based Cu(II)–selective sensor has been developed using synthesized 5,10,15,20‐tetrakis(4‐methoxycarbonylphenyl)porphyrin as an ionophore. The Cu(II)–selective sensor exhibits a Nernstian response for Cu(II) ion over a wide concentration range of 1.0 × 10−5 to 1.0 × 10−1 mol L−1 with the slope of 27.0 ± 2.5 mV/decade, and a lower limit of detection of 1.88 × 10−6 mol L−1. The novel sensor shows good repeatability and high selectivity for Cu(II) ions over other mono‐, bi‐ and trivalent cations. The sensor potential response remains unaffected by pH in the range of 4.4–10.6 and exhibits a fast response time of less than 10s. Finally the developed Cu(II)–selective sensor has been successfully used as an indicator electrode in the potentiometric titration of Cu2+ against ethylenediaminetetraacetic acid and also in the determination of Cu(II) ion concentration in different water and beverage samples.
In this study, a novel potentiometric sensor was developed for the determination of Cu2+ ions. The developed sensor exhibits a linear response over a wide concentration range and has a very low detection limit. In addition, the copper(II)–selective sensor has advantages such as high selectivity, short response time, low cost, good repeatability, and stability.</description><identifier>ISSN: 0009-4536</identifier><identifier>EISSN: 2192-6549</identifier><identifier>DOI: 10.1002/jccs.202200168</identifier><language>eng</language><publisher>Weinheim: Wiley‐VCH Verlag GmbH & Co. KGaA</publisher><subject>Copper ; copper(II) ; Ion concentration ; Porphyrins ; potentiometry ; PVC membrane ; Response time ; Selectivity ; sensor ; Titration</subject><ispartof>Journal of the Chinese Chemical Society (Taipei), 2022-07, Vol.69 (7), p.1060-1069</ispartof><rights>2022 Chemical Society Located in Taipei and Wiley‐VCH GmbH.</rights><rights>2022 The Chemical Society Located in Taipei & Wiley‐VCH GmbH</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3</citedby><cites>FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3</cites><orcidid>0000-0001-5185-9681 ; 0000-0003-4690-4323</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Özbek, Oguz</creatorcontrib><creatorcontrib>Isildak, Ömer</creatorcontrib><title>Potentiometric determination of copper(II) ions based on a porphyrin derivative</title><title>Journal of the Chinese Chemical Society (Taipei)</title><description>A novel poly(vinyl chloride; PVC) membrane‐based Cu(II)–selective sensor has been developed using synthesized 5,10,15,20‐tetrakis(4‐methoxycarbonylphenyl)porphyrin as an ionophore. The Cu(II)–selective sensor exhibits a Nernstian response for Cu(II) ion over a wide concentration range of 1.0 × 10−5 to 1.0 × 10−1 mol L−1 with the slope of 27.0 ± 2.5 mV/decade, and a lower limit of detection of 1.88 × 10−6 mol L−1. The novel sensor shows good repeatability and high selectivity for Cu(II) ions over other mono‐, bi‐ and trivalent cations. The sensor potential response remains unaffected by pH in the range of 4.4–10.6 and exhibits a fast response time of less than 10s. Finally the developed Cu(II)–selective sensor has been successfully used as an indicator electrode in the potentiometric titration of Cu2+ against ethylenediaminetetraacetic acid and also in the determination of Cu(II) ion concentration in different water and beverage samples.
In this study, a novel potentiometric sensor was developed for the determination of Cu2+ ions. The developed sensor exhibits a linear response over a wide concentration range and has a very low detection limit. In addition, the copper(II)–selective sensor has advantages such as high selectivity, short response time, low cost, good repeatability, and stability.</description><subject>Copper</subject><subject>copper(II)</subject><subject>Ion concentration</subject><subject>Porphyrins</subject><subject>potentiometry</subject><subject>PVC membrane</subject><subject>Response time</subject><subject>Selectivity</subject><subject>sensor</subject><subject>Titration</subject><issn>0009-4536</issn><issn>2192-6549</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNqFkM1LAzEQxYMoWKtXzwEvetg6yW62m6MsflQKFdRzyM4mmNJu1mRb6X9vSkWPngbevN98PEIuGUwYAL9dIsYJB84BWFkdkRFnkmelKOQxGQGAzAqRl6fkLMYlQJFzIUdk8eIH0w3Or80QHNLWDCasXaeT1FFvKfq-N-F6NruhSYm00dG0NPU07X3oP3bBdYkKbpuQrTknJ1avorn4qWPy_nD_Vj9l88XjrL6bZ5izaZVhaxssNBrLp7ZEofe3gtSlrKABiRW0RWVbzaS12IhctFPODMs1Wtmg1fmYXB3m9sF_bkwc1NJvQpdWKl5KkCJ9VyTX5ODC4GMMxqo-uLUOO8VA7UNT-9DUb2gJkAfgy63M7h-3eq7r1z_2GzgNcig</recordid><startdate>202207</startdate><enddate>202207</enddate><creator>Özbek, Oguz</creator><creator>Isildak, Ömer</creator><general>Wiley‐VCH Verlag GmbH & Co. KGaA</general><general>Wiley Subscription Services, Inc</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-5185-9681</orcidid><orcidid>https://orcid.org/0000-0003-4690-4323</orcidid></search><sort><creationdate>202207</creationdate><title>Potentiometric determination of copper(II) ions based on a porphyrin derivative</title><author>Özbek, Oguz ; Isildak, Ömer</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Copper</topic><topic>copper(II)</topic><topic>Ion concentration</topic><topic>Porphyrins</topic><topic>potentiometry</topic><topic>PVC membrane</topic><topic>Response time</topic><topic>Selectivity</topic><topic>sensor</topic><topic>Titration</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Özbek, Oguz</creatorcontrib><creatorcontrib>Isildak, Ömer</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of the Chinese Chemical Society (Taipei)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Özbek, Oguz</au><au>Isildak, Ömer</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Potentiometric determination of copper(II) ions based on a porphyrin derivative</atitle><jtitle>Journal of the Chinese Chemical Society (Taipei)</jtitle><date>2022-07</date><risdate>2022</risdate><volume>69</volume><issue>7</issue><spage>1060</spage><epage>1069</epage><pages>1060-1069</pages><issn>0009-4536</issn><eissn>2192-6549</eissn><abstract>A novel poly(vinyl chloride; PVC) membrane‐based Cu(II)–selective sensor has been developed using synthesized 5,10,15,20‐tetrakis(4‐methoxycarbonylphenyl)porphyrin as an ionophore. The Cu(II)–selective sensor exhibits a Nernstian response for Cu(II) ion over a wide concentration range of 1.0 × 10−5 to 1.0 × 10−1 mol L−1 with the slope of 27.0 ± 2.5 mV/decade, and a lower limit of detection of 1.88 × 10−6 mol L−1. The novel sensor shows good repeatability and high selectivity for Cu(II) ions over other mono‐, bi‐ and trivalent cations. The sensor potential response remains unaffected by pH in the range of 4.4–10.6 and exhibits a fast response time of less than 10s. Finally the developed Cu(II)–selective sensor has been successfully used as an indicator electrode in the potentiometric titration of Cu2+ against ethylenediaminetetraacetic acid and also in the determination of Cu(II) ion concentration in different water and beverage samples.
In this study, a novel potentiometric sensor was developed for the determination of Cu2+ ions. The developed sensor exhibits a linear response over a wide concentration range and has a very low detection limit. In addition, the copper(II)–selective sensor has advantages such as high selectivity, short response time, low cost, good repeatability, and stability.</abstract><cop>Weinheim</cop><pub>Wiley‐VCH Verlag GmbH & Co. KGaA</pub><doi>10.1002/jccs.202200168</doi><tpages>10</tpages><orcidid>https://orcid.org/0000-0001-5185-9681</orcidid><orcidid>https://orcid.org/0000-0003-4690-4323</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0009-4536 |
ispartof | Journal of the Chinese Chemical Society (Taipei), 2022-07, Vol.69 (7), p.1060-1069 |
issn | 0009-4536 2192-6549 |
language | eng |
recordid | cdi_proquest_journals_2690952594 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | Copper copper(II) Ion concentration Porphyrins potentiometry PVC membrane Response time Selectivity sensor Titration |
title | Potentiometric determination of copper(II) ions based on a porphyrin derivative |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T17%3A37%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Potentiometric%20determination%20of%20copper(II)%20ions%20based%20on%20a%20porphyrin%20derivative&rft.jtitle=Journal%20of%20the%20Chinese%20Chemical%20Society%20(Taipei)&rft.au=%C3%96zbek,%20Oguz&rft.date=2022-07&rft.volume=69&rft.issue=7&rft.spage=1060&rft.epage=1069&rft.pages=1060-1069&rft.issn=0009-4536&rft.eissn=2192-6549&rft_id=info:doi/10.1002/jccs.202200168&rft_dat=%3Cproquest_cross%3E2690952594%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3178-cdfbc4acef27f6c5a219209a6980b09c80d48fda19ffcb535d721e13acf9bcfa3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2690952594&rft_id=info:pmid/&rfr_iscdi=true |