Loading…

Practical realization and design of three-cascade prism mass analyzer for isotopic analysis of H-He mixtures using MS-platform technology

The paper presents the construction of a mass analyzer for the analysis of hydrogen-helium mixtures based on a magnetic prism using a three-stage circuit that includes two cylindrical capacitors. The choice of an ion-optical scheme that provides a high resolution of 3300, which is necessary for the...

Full description

Saved in:
Bibliographic Details
Published in:Journal of physics. Conference series 2022-12, Vol.2388 (1), p.12020
Main Authors: Gromov, I A, Gall, L N, Sachenko, V D, Gall, N R, Rajabov, Sh U
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c225t-2b1d030b62aae4c37f034f65b5984cb631e5d309938e5ff3137bd56add4a4f953
container_end_page
container_issue 1
container_start_page 12020
container_title Journal of physics. Conference series
container_volume 2388
creator Gromov, I A
Gall, L N
Sachenko, V D
Gall, N R
Rajabov, Sh U
description The paper presents the construction of a mass analyzer for the analysis of hydrogen-helium mixtures based on a magnetic prism using a three-stage circuit that includes two cylindrical capacitors. The choice of an ion-optical scheme that provides a high resolution of 3300, which is necessary for the separation of all nuclides formed during the analysis of hydrogen-helium mixtures, is justified. It is shown that the innovative «MS-Platform» technology makes it possible to ensure high assembly accuracy of the elements of the prism mass analyzer ion-optical circuit, which is necessary to realize all the advantages of a prism mass spectrometer compared to sector ones.
doi_str_mv 10.1088/1742-6596/2388/1/012020
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2753722232</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2753722232</sourcerecordid><originalsourceid>FETCH-LOGICAL-c225t-2b1d030b62aae4c37f034f65b5984cb631e5d309938e5ff3137bd56add4a4f953</originalsourceid><addsrcrecordid>eNqFkNlKxDAUhosouD6DAe-EOlmaLpcyqKMoCup1SLOMkbapORlw5g18a1sqiiCYm-Qk33-SfElyTPAZwWU5I0VG05xX-YyysZxhQjHFW8ne98n297osd5N9gFeM2TCKveTjIUgVnZINCkY2biOj8x2SnUbagFt2yFsUX4IxqZKgpDaoDw5a1EqAAZPNemMCsj4gBz763qlpFxyM0UW6MKh173EVDKAVuG6J7h7TvpFxyLQoGvXS-cYv14fJjpUNmKOv-SB5vrx4mi_S2_ur6_n5baoo5TGlNdGY4TqnUppMscJiltmc17wqM1XnjBiuGa4qVhpuLSOsqDXPpdaZzGzF2UFyMvXtg39bGYji1a_C8GQQtOCsoJQyOlDFRKngAYKxYvh2K8NaECxG72I0Kka7YvQuiJi8D8nTKel8_9P65mH--BsUvbYDzP6A_7viExQ1lKE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2753722232</pqid></control><display><type>article</type><title>Practical realization and design of three-cascade prism mass analyzer for isotopic analysis of H-He mixtures using MS-platform technology</title><source>Publicly Available Content Database</source><source>Free Full-Text Journals in Chemistry</source><creator>Gromov, I A ; Gall, L N ; Sachenko, V D ; Gall, N R ; Rajabov, Sh U</creator><creatorcontrib>Gromov, I A ; Gall, L N ; Sachenko, V D ; Gall, N R ; Rajabov, Sh U</creatorcontrib><description>The paper presents the construction of a mass analyzer for the analysis of hydrogen-helium mixtures based on a magnetic prism using a three-stage circuit that includes two cylindrical capacitors. The choice of an ion-optical scheme that provides a high resolution of 3300, which is necessary for the separation of all nuclides formed during the analysis of hydrogen-helium mixtures, is justified. It is shown that the innovative «MS-Platform» technology makes it possible to ensure high assembly accuracy of the elements of the prism mass analyzer ion-optical circuit, which is necessary to realize all the advantages of a prism mass spectrometer compared to sector ones.</description><identifier>ISSN: 1742-6588</identifier><identifier>EISSN: 1742-6596</identifier><identifier>DOI: 10.1088/1742-6596/2388/1/012020</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Circuits ; Helium ; Hydrogen ; Mixtures ; Nuclides ; Physics</subject><ispartof>Journal of physics. Conference series, 2022-12, Vol.2388 (1), p.12020</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>Published under licence by IOP Publishing Ltd. This work is published under http://creativecommons.org/licenses/by/3.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c225t-2b1d030b62aae4c37f034f65b5984cb631e5d309938e5ff3137bd56add4a4f953</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2753722232?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590</link.rule.ids></links><search><creatorcontrib>Gromov, I A</creatorcontrib><creatorcontrib>Gall, L N</creatorcontrib><creatorcontrib>Sachenko, V D</creatorcontrib><creatorcontrib>Gall, N R</creatorcontrib><creatorcontrib>Rajabov, Sh U</creatorcontrib><title>Practical realization and design of three-cascade prism mass analyzer for isotopic analysis of H-He mixtures using MS-platform technology</title><title>Journal of physics. Conference series</title><addtitle>J. Phys.: Conf. Ser</addtitle><description>The paper presents the construction of a mass analyzer for the analysis of hydrogen-helium mixtures based on a magnetic prism using a three-stage circuit that includes two cylindrical capacitors. The choice of an ion-optical scheme that provides a high resolution of 3300, which is necessary for the separation of all nuclides formed during the analysis of hydrogen-helium mixtures, is justified. It is shown that the innovative «MS-Platform» technology makes it possible to ensure high assembly accuracy of the elements of the prism mass analyzer ion-optical circuit, which is necessary to realize all the advantages of a prism mass spectrometer compared to sector ones.</description><subject>Circuits</subject><subject>Helium</subject><subject>Hydrogen</subject><subject>Mixtures</subject><subject>Nuclides</subject><subject>Physics</subject><issn>1742-6588</issn><issn>1742-6596</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqFkNlKxDAUhosouD6DAe-EOlmaLpcyqKMoCup1SLOMkbapORlw5g18a1sqiiCYm-Qk33-SfElyTPAZwWU5I0VG05xX-YyysZxhQjHFW8ne98n297osd5N9gFeM2TCKveTjIUgVnZINCkY2biOj8x2SnUbagFt2yFsUX4IxqZKgpDaoDw5a1EqAAZPNemMCsj4gBz763qlpFxyM0UW6MKh173EVDKAVuG6J7h7TvpFxyLQoGvXS-cYv14fJjpUNmKOv-SB5vrx4mi_S2_ur6_n5baoo5TGlNdGY4TqnUppMscJiltmc17wqM1XnjBiuGa4qVhpuLSOsqDXPpdaZzGzF2UFyMvXtg39bGYji1a_C8GQQtOCsoJQyOlDFRKngAYKxYvh2K8NaECxG72I0Kka7YvQuiJi8D8nTKel8_9P65mH--BsUvbYDzP6A_7viExQ1lKE</recordid><startdate>20221201</startdate><enddate>20221201</enddate><creator>Gromov, I A</creator><creator>Gall, L N</creator><creator>Sachenko, V D</creator><creator>Gall, N R</creator><creator>Rajabov, Sh U</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>H8D</scope><scope>HCIFZ</scope><scope>L7M</scope><scope>P5Z</scope><scope>P62</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20221201</creationdate><title>Practical realization and design of three-cascade prism mass analyzer for isotopic analysis of H-He mixtures using MS-platform technology</title><author>Gromov, I A ; Gall, L N ; Sachenko, V D ; Gall, N R ; Rajabov, Sh U</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c225t-2b1d030b62aae4c37f034f65b5984cb631e5d309938e5ff3137bd56add4a4f953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Circuits</topic><topic>Helium</topic><topic>Hydrogen</topic><topic>Mixtures</topic><topic>Nuclides</topic><topic>Physics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gromov, I A</creatorcontrib><creatorcontrib>Gall, L N</creatorcontrib><creatorcontrib>Sachenko, V D</creatorcontrib><creatorcontrib>Gall, N R</creatorcontrib><creatorcontrib>Rajabov, Sh U</creatorcontrib><collection>Open Access: IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies &amp; Aerospace Database‎ (1962 - current)</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Aerospace Database</collection><collection>SciTech Premium Collection</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>ProQuest advanced technologies &amp; aerospace journals</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Journal of physics. Conference series</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gromov, I A</au><au>Gall, L N</au><au>Sachenko, V D</au><au>Gall, N R</au><au>Rajabov, Sh U</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Practical realization and design of three-cascade prism mass analyzer for isotopic analysis of H-He mixtures using MS-platform technology</atitle><jtitle>Journal of physics. Conference series</jtitle><addtitle>J. Phys.: Conf. Ser</addtitle><date>2022-12-01</date><risdate>2022</risdate><volume>2388</volume><issue>1</issue><spage>12020</spage><pages>12020-</pages><issn>1742-6588</issn><eissn>1742-6596</eissn><abstract>The paper presents the construction of a mass analyzer for the analysis of hydrogen-helium mixtures based on a magnetic prism using a three-stage circuit that includes two cylindrical capacitors. The choice of an ion-optical scheme that provides a high resolution of 3300, which is necessary for the separation of all nuclides formed during the analysis of hydrogen-helium mixtures, is justified. It is shown that the innovative «MS-Platform» technology makes it possible to ensure high assembly accuracy of the elements of the prism mass analyzer ion-optical circuit, which is necessary to realize all the advantages of a prism mass spectrometer compared to sector ones.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1742-6596/2388/1/012020</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1742-6588
ispartof Journal of physics. Conference series, 2022-12, Vol.2388 (1), p.12020
issn 1742-6588
1742-6596
language eng
recordid cdi_proquest_journals_2753722232
source Publicly Available Content Database; Free Full-Text Journals in Chemistry
subjects Circuits
Helium
Hydrogen
Mixtures
Nuclides
Physics
title Practical realization and design of three-cascade prism mass analyzer for isotopic analysis of H-He mixtures using MS-platform technology
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T05%3A05%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Practical%20realization%20and%20design%20of%20three-cascade%20prism%20mass%20analyzer%20for%20isotopic%20analysis%20of%20H-He%20mixtures%20using%20MS-platform%20technology&rft.jtitle=Journal%20of%20physics.%20Conference%20series&rft.au=Gromov,%20I%20A&rft.date=2022-12-01&rft.volume=2388&rft.issue=1&rft.spage=12020&rft.pages=12020-&rft.issn=1742-6588&rft.eissn=1742-6596&rft_id=info:doi/10.1088/1742-6596/2388/1/012020&rft_dat=%3Cproquest_cross%3E2753722232%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c225t-2b1d030b62aae4c37f034f65b5984cb631e5d309938e5ff3137bd56add4a4f953%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2753722232&rft_id=info:pmid/&rfr_iscdi=true