Corrosion Failure of the Rocky Point Viaduct

The Rocky Point Viaduct, located near Port Orford, OR, was replaced after only 40 years of service. A beam from the original viaduct was studied in detail to determine the mechanisms contributing to severe corrosion damage to the structure. Results are presented from the delamination survey, potenti...

Full description

Saved in:
Bibliographic Details
Published in:Journal of failure analysis and prevention 2022-12, Vol.22 (6), p.2467-2478
Main Authors: Covino, B. S., Cramer, S. D., Holcomb, G. R., Bullard, S. J., Summers, C. A., Dahlin, C. L., Laylor, H. M., McGill, G. E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493
cites cdi_FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493
container_end_page 2478
container_issue 6
container_start_page 2467
container_title Journal of failure analysis and prevention
container_volume 22
creator Covino, B. S.
Cramer, S. D.
Holcomb, G. R.
Bullard, S. J.
Summers, C. A.
Dahlin, C. L.
Laylor, H. M.
McGill, G. E.
description The Rocky Point Viaduct, located near Port Orford, OR, was replaced after only 40 years of service. A beam from the original viaduct was studied in detail to determine the mechanisms contributing to severe corrosion damage to the structure. Results are presented from the delamination survey, potential and corrosion mapping, concrete chemistry, and concrete physical properties. The major cause of corrosion damage appears to have been the presence of both pre-existing and environmentally-delivered chlorides in the concrete.
doi_str_mv 10.1007/s11668-022-01546-y
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2755891590</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2755891590</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493</originalsourceid><addsrcrecordid>eNp9kE1LxDAQhoMouK7-AU8Fr0bzNZP2KIurwoIi6jWkaVa7rs2atIf-e6MVvHmaOTzvO8xDyClnF5wxfZk4RywpE4IyDgrpuEdmXIuSAmq1n3dQmmomqkNylNKGMQlciRk5X4QYQ2pDVyxtux2iL8K66N988Rjc-1g8hLbri5fWNoPrj8nB2m6TP_mdc_K8vH5a3NLV_c3d4mpFnUTZU0SJHqTlDWhVyxqkbxhiBd6Vtqwtc9rWUKnGg3IaUAgvNSr0mZFCVXJOzqbeXQyfg0-92YQhdvmkERqgrDhULFNiolx-IEW_NrvYftg4Gs7MtxUzWTHZivmxYsYcklMoZbh79fGv-p_UF49-Y0E</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2755891590</pqid></control><display><type>article</type><title>Corrosion Failure of the Rocky Point Viaduct</title><source>Springer Link</source><creator>Covino, B. S. ; Cramer, S. D. ; Holcomb, G. R. ; Bullard, S. J. ; Summers, C. A. ; Dahlin, C. L. ; Laylor, H. M. ; McGill, G. E.</creator><creatorcontrib>Covino, B. S. ; Cramer, S. D. ; Holcomb, G. R. ; Bullard, S. J. ; Summers, C. A. ; Dahlin, C. L. ; Laylor, H. M. ; McGill, G. E.</creatorcontrib><description>The Rocky Point Viaduct, located near Port Orford, OR, was replaced after only 40 years of service. A beam from the original viaduct was studied in detail to determine the mechanisms contributing to severe corrosion damage to the structure. Results are presented from the delamination survey, potential and corrosion mapping, concrete chemistry, and concrete physical properties. The major cause of corrosion damage appears to have been the presence of both pre-existing and environmentally-delivered chlorides in the concrete.</description><identifier>ISSN: 1547-7029</identifier><identifier>EISSN: 1728-5674</identifier><identifier>EISSN: 1864-1245</identifier><identifier>DOI: 10.1007/s11668-022-01546-y</identifier><language>eng</language><publisher>New York: Springer US</publisher><subject>Case History---Peer-Reviewed ; Characterization and Evaluation of Materials ; Chemistry and Materials Science ; Classical Mechanics ; Corrosion and Coatings ; Corrosion potential ; Damage ; Materials Science ; Physical properties ; Quality Control ; Reliability ; Safety and Risk ; Solid Mechanics ; Tribology ; Viaducts</subject><ispartof>Journal of failure analysis and prevention, 2022-12, Vol.22 (6), p.2467-2478</ispartof><rights>ASM International 2022. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493</citedby><cites>FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Covino, B. S.</creatorcontrib><creatorcontrib>Cramer, S. D.</creatorcontrib><creatorcontrib>Holcomb, G. R.</creatorcontrib><creatorcontrib>Bullard, S. J.</creatorcontrib><creatorcontrib>Summers, C. A.</creatorcontrib><creatorcontrib>Dahlin, C. L.</creatorcontrib><creatorcontrib>Laylor, H. M.</creatorcontrib><creatorcontrib>McGill, G. E.</creatorcontrib><title>Corrosion Failure of the Rocky Point Viaduct</title><title>Journal of failure analysis and prevention</title><addtitle>J Fail. Anal. and Preven</addtitle><description>The Rocky Point Viaduct, located near Port Orford, OR, was replaced after only 40 years of service. A beam from the original viaduct was studied in detail to determine the mechanisms contributing to severe corrosion damage to the structure. Results are presented from the delamination survey, potential and corrosion mapping, concrete chemistry, and concrete physical properties. The major cause of corrosion damage appears to have been the presence of both pre-existing and environmentally-delivered chlorides in the concrete.</description><subject>Case History---Peer-Reviewed</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry and Materials Science</subject><subject>Classical Mechanics</subject><subject>Corrosion and Coatings</subject><subject>Corrosion potential</subject><subject>Damage</subject><subject>Materials Science</subject><subject>Physical properties</subject><subject>Quality Control</subject><subject>Reliability</subject><subject>Safety and Risk</subject><subject>Solid Mechanics</subject><subject>Tribology</subject><subject>Viaducts</subject><issn>1547-7029</issn><issn>1728-5674</issn><issn>1864-1245</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LxDAQhoMouK7-AU8Fr0bzNZP2KIurwoIi6jWkaVa7rs2atIf-e6MVvHmaOTzvO8xDyClnF5wxfZk4RywpE4IyDgrpuEdmXIuSAmq1n3dQmmomqkNylNKGMQlciRk5X4QYQ2pDVyxtux2iL8K66N988Rjc-1g8hLbri5fWNoPrj8nB2m6TP_mdc_K8vH5a3NLV_c3d4mpFnUTZU0SJHqTlDWhVyxqkbxhiBd6Vtqwtc9rWUKnGg3IaUAgvNSr0mZFCVXJOzqbeXQyfg0-92YQhdvmkERqgrDhULFNiolx-IEW_NrvYftg4Gs7MtxUzWTHZivmxYsYcklMoZbh79fGv-p_UF49-Y0E</recordid><startdate>20221201</startdate><enddate>20221201</enddate><creator>Covino, B. S.</creator><creator>Cramer, S. D.</creator><creator>Holcomb, G. R.</creator><creator>Bullard, S. J.</creator><creator>Summers, C. A.</creator><creator>Dahlin, C. L.</creator><creator>Laylor, H. M.</creator><creator>McGill, G. E.</creator><general>Springer US</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7TA</scope><scope>7TB</scope><scope>8BQ</scope><scope>8FD</scope><scope>FR3</scope><scope>JG9</scope><scope>KR7</scope></search><sort><creationdate>20221201</creationdate><title>Corrosion Failure of the Rocky Point Viaduct</title><author>Covino, B. S. ; Cramer, S. D. ; Holcomb, G. R. ; Bullard, S. J. ; Summers, C. A. ; Dahlin, C. L. ; Laylor, H. M. ; McGill, G. E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>Case History---Peer-Reviewed</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry and Materials Science</topic><topic>Classical Mechanics</topic><topic>Corrosion and Coatings</topic><topic>Corrosion potential</topic><topic>Damage</topic><topic>Materials Science</topic><topic>Physical properties</topic><topic>Quality Control</topic><topic>Reliability</topic><topic>Safety and Risk</topic><topic>Solid Mechanics</topic><topic>Tribology</topic><topic>Viaducts</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Covino, B. S.</creatorcontrib><creatorcontrib>Cramer, S. D.</creatorcontrib><creatorcontrib>Holcomb, G. R.</creatorcontrib><creatorcontrib>Bullard, S. J.</creatorcontrib><creatorcontrib>Summers, C. A.</creatorcontrib><creatorcontrib>Dahlin, C. L.</creatorcontrib><creatorcontrib>Laylor, H. M.</creatorcontrib><creatorcontrib>McGill, G. E.</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Materials Business File</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Materials Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of failure analysis and prevention</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Covino, B. S.</au><au>Cramer, S. D.</au><au>Holcomb, G. R.</au><au>Bullard, S. J.</au><au>Summers, C. A.</au><au>Dahlin, C. L.</au><au>Laylor, H. M.</au><au>McGill, G. E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Corrosion Failure of the Rocky Point Viaduct</atitle><jtitle>Journal of failure analysis and prevention</jtitle><stitle>J Fail. Anal. and Preven</stitle><date>2022-12-01</date><risdate>2022</risdate><volume>22</volume><issue>6</issue><spage>2467</spage><epage>2478</epage><pages>2467-2478</pages><issn>1547-7029</issn><eissn>1728-5674</eissn><eissn>1864-1245</eissn><abstract>The Rocky Point Viaduct, located near Port Orford, OR, was replaced after only 40 years of service. A beam from the original viaduct was studied in detail to determine the mechanisms contributing to severe corrosion damage to the structure. Results are presented from the delamination survey, potential and corrosion mapping, concrete chemistry, and concrete physical properties. The major cause of corrosion damage appears to have been the presence of both pre-existing and environmentally-delivered chlorides in the concrete.</abstract><cop>New York</cop><pub>Springer US</pub><doi>10.1007/s11668-022-01546-y</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1547-7029
ispartof Journal of failure analysis and prevention, 2022-12, Vol.22 (6), p.2467-2478
issn 1547-7029
1728-5674
1864-1245
language eng
recordid cdi_proquest_journals_2755891590
source Springer Link
subjects Case History---Peer-Reviewed
Characterization and Evaluation of Materials
Chemistry and Materials Science
Classical Mechanics
Corrosion and Coatings
Corrosion potential
Damage
Materials Science
Physical properties
Quality Control
Reliability
Safety and Risk
Solid Mechanics
Tribology
Viaducts
title Corrosion Failure of the Rocky Point Viaduct
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A53%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Corrosion%20Failure%20of%20the%20Rocky%20Point%20Viaduct&rft.jtitle=Journal%20of%20failure%20analysis%20and%20prevention&rft.au=Covino,%20B.%20S.&rft.date=2022-12-01&rft.volume=22&rft.issue=6&rft.spage=2467&rft.epage=2478&rft.pages=2467-2478&rft.issn=1547-7029&rft.eissn=1728-5674&rft_id=info:doi/10.1007/s11668-022-01546-y&rft_dat=%3Cproquest_cross%3E2755891590%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c363t-6636e53a1d574b3b53ed06695ec8a8ba0c7ab594de54c75622e37646e66932493%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2755891590&rft_id=info:pmid/&rfr_iscdi=true