A method for organizing the access to the slow-control channels of the ZEUS detector

The slow-control system operation consists in periodic polling of all parameters that need to be controlled and comparing values obtained with admissible deviations from normal values. This is necessary for the safe functioning of the facility and for reliability of the experimental data obtained. F...

Full description

Saved in:
Bibliographic Details
Published in:Instruments and experimental techniques (New York) 2000-03, Vol.43 (2), p.195-200
Main Authors: Basiladze, S. G., Erasov, A. B.
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The slow-control system operation consists in periodic polling of all parameters that need to be controlled and comparing values obtained with admissible deviations from normal values. This is necessary for the safe functioning of the facility and for reliability of the experimental data obtained. For modern experimental setups, when a large number of parameters need to be monitored, the problem of access to the slow-control data becomes complex. In this paper, a method for organizing the access to the slow-control channels is described. The method is based on using two search structures corresponding to the common database for channels and parameters.