Loading…
Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Électrique, DEFNAT (Tunisia), was carried out from April to June 2022. Two BIPM Zener diode-based travelling standards (Fluke...
Saved in:
Published in: | Metrologia 2023-01, Vol.60 (1A), p.1003 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c238t-1b9b32ff90424cc248aa39272f4569f365d563b992a598204ee402693fddec7e3 |
---|---|
cites | |
container_end_page | |
container_issue | 1A |
container_start_page | 1003 |
container_title | Metrologia |
container_volume | 60 |
creator | Solve, Stephane Chayramy, Regis Stock, Michael Zouaoui, Jihène |
description | As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Électrique, DEFNAT (Tunisia), was carried out from April to June 2022. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_E (ZE) and BIPM_F (ZF), were transported by freight to DEFNAT to be measured and back to the BIPM for checking the stability of the traveling standards. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard.
The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT,
U
DEFNAT
, and those assigned by the BIPM, at the BIPM,
U
BIPM
, at the reference date of the 15th of May 2022.
U
DEFNAT
-
U
BIPM
= 0.03 μV;
u
c
= 0.03 μV, at 1.018 V
U
DEFNAT
-
U
BIPM
= 0.44 μV;
u
c
= 0.12 μV, at 10 V
where
u
c
is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DEFNAT, based on
K
J
, and the uncertainty related to the comparison.
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
https://www.bipm.org/kcdb/
.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA). |
doi_str_mv | 10.1088/0026-1394/60/1A/01003 |
format | article |
fullrecord | <record><control><sourceid>proquest_iop_j</sourceid><recordid>TN_cdi_proquest_journals_2801293396</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2801293396</sourcerecordid><originalsourceid>FETCH-LOGICAL-c238t-1b9b32ff90424cc248aa39272f4569f365d563b992a598204ee402693fddec7e3</originalsourceid><addsrcrecordid>eNp9kU1OwzAQhS0EEqVwBCRLbEAi7YydPy8DFChQYFHYWk7iQKDExU6FeiVOidMiYMXKo9H33ozfELKPMEBI0yEAiwPkIhzGMMRsCAjAN0gP4xSDJEqiTdL7YbbJjnMvAJiwKOmRz5N6plpt1YwW5m2ubO1MQ01FcQCY0keqmpIi-MK1vlS2dDTX7YfWDT0bnd9mU3o4XTS1q9XRim2fNT0Z30-OaTa39Yy2hl4tGk0ZMEYP_YC2c-8o0zyZunla0fRVL_8u0PUGo0lwjThQK9_8aJdsVWrm9N732ycP56Pp6WVwc3cxPs1ugoLxtA0wFzlnVSUgZGFRsDBViguWsCqMYlHxOCqjmOdCMBWJlEGodejDEbwqS10kmvfJwdp3bs37QrtWvpiFbfxIyVJAJjgXsaeiNVVY45zVlfTffVN2KRFkdxbZRS67yGXsO5lcncXrcK2rzfzX-H_NF1seiLM</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2801293396</pqid></control><display><type>article</type><title>Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)</title><source>Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List)</source><creator>Solve, Stephane ; Chayramy, Regis ; Stock, Michael ; Zouaoui, Jihène</creator><creatorcontrib>Solve, Stephane ; Chayramy, Regis ; Stock, Michael ; Zouaoui, Jihène</creatorcontrib><description>As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Électrique, DEFNAT (Tunisia), was carried out from April to June 2022. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_E (ZE) and BIPM_F (ZF), were transported by freight to DEFNAT to be measured and back to the BIPM for checking the stability of the traveling standards. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard.
The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT,
U
DEFNAT
, and those assigned by the BIPM, at the BIPM,
U
BIPM
, at the reference date of the 15th of May 2022.
U
DEFNAT
-
U
BIPM
= 0.03 μV;
u
c
= 0.03 μV, at 1.018 V
U
DEFNAT
-
U
BIPM
= 0.44 μV;
u
c
= 0.12 μV, at 10 V
where
u
c
is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DEFNAT, based on
K
J
, and the uncertainty related to the comparison.
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
https://www.bipm.org/kcdb/
.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).</description><identifier>ISSN: 0026-1394</identifier><identifier>EISSN: 1681-7575</identifier><identifier>DOI: 10.1088/0026-1394/60/1A/01003</identifier><identifier>CODEN: MTRGAU</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Avalanche diodes ; Electric potential ; Electromotive forces ; Uncertainty ; Voltage</subject><ispartof>Metrologia, 2023-01, Vol.60 (1A), p.1003</ispartof><rights>2023 BIPM & IOP Publishing Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c238t-1b9b32ff90424cc248aa39272f4569f365d563b992a598204ee402693fddec7e3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,27906,27907</link.rule.ids></links><search><creatorcontrib>Solve, Stephane</creatorcontrib><creatorcontrib>Chayramy, Regis</creatorcontrib><creatorcontrib>Stock, Michael</creatorcontrib><creatorcontrib>Zouaoui, Jihène</creatorcontrib><title>Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)</title><title>Metrologia</title><addtitle>MET</addtitle><addtitle>Metrologia</addtitle><description>As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Électrique, DEFNAT (Tunisia), was carried out from April to June 2022. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_E (ZE) and BIPM_F (ZF), were transported by freight to DEFNAT to be measured and back to the BIPM for checking the stability of the traveling standards. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard.
The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT,
U
DEFNAT
, and those assigned by the BIPM, at the BIPM,
U
BIPM
, at the reference date of the 15th of May 2022.
U
DEFNAT
-
U
BIPM
= 0.03 μV;
u
c
= 0.03 μV, at 1.018 V
U
DEFNAT
-
U
BIPM
= 0.44 μV;
u
c
= 0.12 μV, at 10 V
where
u
c
is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DEFNAT, based on
K
J
, and the uncertainty related to the comparison.
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
https://www.bipm.org/kcdb/
.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).</description><subject>Avalanche diodes</subject><subject>Electric potential</subject><subject>Electromotive forces</subject><subject>Uncertainty</subject><subject>Voltage</subject><issn>0026-1394</issn><issn>1681-7575</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kU1OwzAQhS0EEqVwBCRLbEAi7YydPy8DFChQYFHYWk7iQKDExU6FeiVOidMiYMXKo9H33ozfELKPMEBI0yEAiwPkIhzGMMRsCAjAN0gP4xSDJEqiTdL7YbbJjnMvAJiwKOmRz5N6plpt1YwW5m2ubO1MQ01FcQCY0keqmpIi-MK1vlS2dDTX7YfWDT0bnd9mU3o4XTS1q9XRim2fNT0Z30-OaTa39Yy2hl4tGk0ZMEYP_YC2c-8o0zyZunla0fRVL_8u0PUGo0lwjThQK9_8aJdsVWrm9N732ycP56Pp6WVwc3cxPs1ugoLxtA0wFzlnVSUgZGFRsDBViguWsCqMYlHxOCqjmOdCMBWJlEGodejDEbwqS10kmvfJwdp3bs37QrtWvpiFbfxIyVJAJjgXsaeiNVVY45zVlfTffVN2KRFkdxbZRS67yGXsO5lcncXrcK2rzfzX-H_NF1seiLM</recordid><startdate>20230101</startdate><enddate>20230101</enddate><creator>Solve, Stephane</creator><creator>Chayramy, Regis</creator><creator>Stock, Michael</creator><creator>Zouaoui, Jihène</creator><general>IOP Publishing</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7U5</scope><scope>8FD</scope><scope>L7M</scope></search><sort><creationdate>20230101</creationdate><title>Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)</title><author>Solve, Stephane ; Chayramy, Regis ; Stock, Michael ; Zouaoui, Jihène</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c238t-1b9b32ff90424cc248aa39272f4569f365d563b992a598204ee402693fddec7e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Avalanche diodes</topic><topic>Electric potential</topic><topic>Electromotive forces</topic><topic>Uncertainty</topic><topic>Voltage</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Solve, Stephane</creatorcontrib><creatorcontrib>Chayramy, Regis</creatorcontrib><creatorcontrib>Stock, Michael</creatorcontrib><creatorcontrib>Zouaoui, Jihène</creatorcontrib><collection>CrossRef</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>Technology Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Metrologia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Solve, Stephane</au><au>Chayramy, Regis</au><au>Stock, Michael</au><au>Zouaoui, Jihène</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)</atitle><jtitle>Metrologia</jtitle><stitle>MET</stitle><addtitle>Metrologia</addtitle><date>2023-01-01</date><risdate>2023</risdate><volume>60</volume><issue>1A</issue><spage>1003</spage><pages>1003-</pages><issn>0026-1394</issn><eissn>1681-7575</eissn><coden>MTRGAU</coden><abstract>As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Laboratoire de Métrologie Électrique, DEFNAT (Tunisia), was carried out from April to June 2022. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_E (ZE) and BIPM_F (ZF), were transported by freight to DEFNAT to be measured and back to the BIPM for checking the stability of the traveling standards. At DEFNAT, the reference standard for DC voltage is a Josephson Voltage Standard (JVS). The output EMF (Electromotive Force) of each travelling standard was measured by direct comparison with the primary standard.
The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by DEFNAT, at the level of 1.018 V and 10 V, at DEFNAT,
U
DEFNAT
, and those assigned by the BIPM, at the BIPM,
U
BIPM
, at the reference date of the 15th of May 2022.
U
DEFNAT
-
U
BIPM
= 0.03 μV;
u
c
= 0.03 μV, at 1.018 V
U
DEFNAT
-
U
BIPM
= 0.44 μV;
u
c
= 0.12 μV, at 10 V
where
u
c
is the combined standard uncertainty associated with the measured difference, including the uncertainty of the representation of the volt at the BIPM and at DEFNAT, based on
K
J
, and the uncertainty related to the comparison.
To reach the main text of this paper, click on
Final Report
. Note that this text is that which appears in Appendix B of the BIPM key comparison database
https://www.bipm.org/kcdb/
.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/0026-1394/60/1A/01003</doi></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0026-1394 |
ispartof | Metrologia, 2023-01, Vol.60 (1A), p.1003 |
issn | 0026-1394 1681-7575 |
language | eng |
recordid | cdi_proquest_journals_2801293396 |
source | Institute of Physics:Jisc Collections:IOP Publishing Read and Publish 2024-2025 (Reading List) |
subjects | Avalanche diodes Electric potential Electromotive forces Uncertainty Voltage |
title | Bilateral comparison of 1.018 V and 10 V standards between DEFNAT (Tunisia) and the BIPM, April to June 2022 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b) |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T08%3A52%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_iop_j&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bilateral%20comparison%20of%201.018%20V%20and%2010%20V%20standards%20between%20DEFNAT%20(Tunisia)%20and%20the%20BIPM,%20April%20to%20June%202022%20(part%20of%20the%20ongoing%20BIPM%20key%20comparison%20BIPM.EM-K11.a%20and%20b)&rft.jtitle=Metrologia&rft.au=Solve,%20Stephane&rft.date=2023-01-01&rft.volume=60&rft.issue=1A&rft.spage=1003&rft.pages=1003-&rft.issn=0026-1394&rft.eissn=1681-7575&rft.coden=MTRGAU&rft_id=info:doi/10.1088/0026-1394/60/1A/01003&rft_dat=%3Cproquest_iop_j%3E2801293396%3C/proquest_iop_j%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c238t-1b9b32ff90424cc248aa39272f4569f365d563b992a598204ee402693fddec7e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2801293396&rft_id=info:pmid/&rfr_iscdi=true |