Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher

In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer g...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2023-07
Main Authors: Mollaebrahimi, A, Amanbayev, D, S Ayet San Andrés, Beck, S, Bergmann, J, Dickel, T, Geissel, H, Hornung, C, Kalantar-Nayestanaki, N, Kripko-Koncz, G, Miskun, I, Nichita, D, Plaß, W R, Pohjalainen, I, Scheidenberger, C, Stanic, G, State, A, Zhao, J
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Mollaebrahimi, A
Amanbayev, D
S Ayet San Andrés
Beck, S
Bergmann, J
Dickel, T
Geissel, H
Hornung, C
Kalantar-Nayestanaki, N
Kripko-Koncz, G
Miskun, I
Nichita, D
Plaß, W R
Pohjalainen, I
Scheidenberger, C
Stanic, G
State, A
Zhao, J
description In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.
doi_str_mv 10.48550/arxiv.2307.15080
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2843960598</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2843960598</sourcerecordid><originalsourceid>FETCH-LOGICAL-a950-5feff2674bed841aa94cfe4afe50e19820d73a54c66f36274956af5287e3c08e3</originalsourceid><addsrcrecordid>eNo1jstqwzAUREWh0JDmA7oTdO30Wg9bXhbTPCBQiNN1uLWvHAdXciWnNH_f9LWaxcyZGcbuUpgrozU8YPjsPuZCQj5PNRi4YhMhZZoYJcQNm8V4BACR5UJrOWG4pZrcyF-GNmBDkXvLxwPxJUa-Qtf0nWt5dY4jvXHrw49XhrNvyXU1r0Y_DN-Jkvr-H11sK772jpc41gcKt-zaYh9p9qdTtls87cpVsnlersvHTYKFhkRbsvbySr1SY1SKWKjakkJLGigtjIAml6hVnWVWZiJXhc7QamFykjUYklN2_1s7BP9-ojjuj_4U3GVxL4ySRQa6MPILdC1VZA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2843960598</pqid></control><display><type>article</type><title>Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher</title><source>Publicly Available Content (ProQuest)</source><creator>Mollaebrahimi, A ; Amanbayev, D ; S Ayet San Andrés ; Beck, S ; Bergmann, J ; Dickel, T ; Geissel, H ; Hornung, C ; Kalantar-Nayestanaki, N ; Kripko-Koncz, G ; Miskun, I ; Nichita, D ; Plaß, W R ; Pohjalainen, I ; Scheidenberger, C ; Stanic, G ; State, A ; Zhao, J</creator><creatorcontrib>Mollaebrahimi, A ; Amanbayev, D ; S Ayet San Andrés ; Beck, S ; Bergmann, J ; Dickel, T ; Geissel, H ; Hornung, C ; Kalantar-Nayestanaki, N ; Kripko-Koncz, G ; Miskun, I ; Nichita, D ; Plaß, W R ; Pohjalainen, I ; Scheidenberger, C ; Stanic, G ; State, A ; Zhao, J</creatorcontrib><description>In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.2307.15080</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Buffers</subject><ispartof>arXiv.org, 2023-07</ispartof><rights>2023. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/2843960598?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>776,780,25731,27902,36989,44566</link.rule.ids></links><search><creatorcontrib>Mollaebrahimi, A</creatorcontrib><creatorcontrib>Amanbayev, D</creatorcontrib><creatorcontrib>S Ayet San Andrés</creatorcontrib><creatorcontrib>Beck, S</creatorcontrib><creatorcontrib>Bergmann, J</creatorcontrib><creatorcontrib>Dickel, T</creatorcontrib><creatorcontrib>Geissel, H</creatorcontrib><creatorcontrib>Hornung, C</creatorcontrib><creatorcontrib>Kalantar-Nayestanaki, N</creatorcontrib><creatorcontrib>Kripko-Koncz, G</creatorcontrib><creatorcontrib>Miskun, I</creatorcontrib><creatorcontrib>Nichita, D</creatorcontrib><creatorcontrib>Plaß, W R</creatorcontrib><creatorcontrib>Pohjalainen, I</creatorcontrib><creatorcontrib>Scheidenberger, C</creatorcontrib><creatorcontrib>Stanic, G</creatorcontrib><creatorcontrib>State, A</creatorcontrib><creatorcontrib>Zhao, J</creatorcontrib><title>Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher</title><title>arXiv.org</title><description>In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.</description><subject>Buffers</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNo1jstqwzAUREWh0JDmA7oTdO30Wg9bXhbTPCBQiNN1uLWvHAdXciWnNH_f9LWaxcyZGcbuUpgrozU8YPjsPuZCQj5PNRi4YhMhZZoYJcQNm8V4BACR5UJrOWG4pZrcyF-GNmBDkXvLxwPxJUa-Qtf0nWt5dY4jvXHrw49XhrNvyXU1r0Y_DN-Jkvr-H11sK772jpc41gcKt-zaYh9p9qdTtls87cpVsnlersvHTYKFhkRbsvbySr1SY1SKWKjakkJLGigtjIAml6hVnWVWZiJXhc7QamFykjUYklN2_1s7BP9-ojjuj_4U3GVxL4ySRQa6MPILdC1VZA</recordid><startdate>20230725</startdate><enddate>20230725</enddate><creator>Mollaebrahimi, A</creator><creator>Amanbayev, D</creator><creator>S Ayet San Andrés</creator><creator>Beck, S</creator><creator>Bergmann, J</creator><creator>Dickel, T</creator><creator>Geissel, H</creator><creator>Hornung, C</creator><creator>Kalantar-Nayestanaki, N</creator><creator>Kripko-Koncz, G</creator><creator>Miskun, I</creator><creator>Nichita, D</creator><creator>Plaß, W R</creator><creator>Pohjalainen, I</creator><creator>Scheidenberger, C</creator><creator>Stanic, G</creator><creator>State, A</creator><creator>Zhao, J</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PTHSS</scope></search><sort><creationdate>20230725</creationdate><title>Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher</title><author>Mollaebrahimi, A ; Amanbayev, D ; S Ayet San Andrés ; Beck, S ; Bergmann, J ; Dickel, T ; Geissel, H ; Hornung, C ; Kalantar-Nayestanaki, N ; Kripko-Koncz, G ; Miskun, I ; Nichita, D ; Plaß, W R ; Pohjalainen, I ; Scheidenberger, C ; Stanic, G ; State, A ; Zhao, J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a950-5feff2674bed841aa94cfe4afe50e19820d73a54c66f36274956af5287e3c08e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Buffers</topic><toplevel>online_resources</toplevel><creatorcontrib>Mollaebrahimi, A</creatorcontrib><creatorcontrib>Amanbayev, D</creatorcontrib><creatorcontrib>S Ayet San Andrés</creatorcontrib><creatorcontrib>Beck, S</creatorcontrib><creatorcontrib>Bergmann, J</creatorcontrib><creatorcontrib>Dickel, T</creatorcontrib><creatorcontrib>Geissel, H</creatorcontrib><creatorcontrib>Hornung, C</creatorcontrib><creatorcontrib>Kalantar-Nayestanaki, N</creatorcontrib><creatorcontrib>Kripko-Koncz, G</creatorcontrib><creatorcontrib>Miskun, I</creatorcontrib><creatorcontrib>Nichita, D</creatorcontrib><creatorcontrib>Plaß, W R</creatorcontrib><creatorcontrib>Pohjalainen, I</creatorcontrib><creatorcontrib>Scheidenberger, C</creatorcontrib><creatorcontrib>Stanic, G</creatorcontrib><creatorcontrib>State, A</creatorcontrib><creatorcontrib>Zhao, J</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>Engineering collection</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mollaebrahimi, A</au><au>Amanbayev, D</au><au>S Ayet San Andrés</au><au>Beck, S</au><au>Bergmann, J</au><au>Dickel, T</au><au>Geissel, H</au><au>Hornung, C</au><au>Kalantar-Nayestanaki, N</au><au>Kripko-Koncz, G</au><au>Miskun, I</au><au>Nichita, D</au><au>Plaß, W R</au><au>Pohjalainen, I</au><au>Scheidenberger, C</au><au>Stanic, G</au><au>State, A</au><au>Zhao, J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher</atitle><jtitle>arXiv.org</jtitle><date>2023-07-25</date><risdate>2023</risdate><eissn>2331-8422</eissn><abstract>In this paper, the major upgrades and technical improvements of the buffer gas handling system for the cryogenic stopping cell of the FRS Ion Catcher at GSI/FAIR (in Darmstadt, Germany) are described. The upgrades include implementation of new gas lines and gas purifiers to achieve a higher buffer gas cleanliness for a more efficient extraction of reactive ions as well as suppression of the molecular background ionized in the stopping cell. Furthermore, additional techniques have been implemented for improved monitoring and quantification of the purity of the helium buffer gas.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.2307.15080</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2023-07
issn 2331-8422
language eng
recordid cdi_proquest_journals_2843960598
source Publicly Available Content (ProQuest)
subjects Buffers
title Recent Upgrades of the Gas Handling System for the Cryogenic Stopping Cell of the FRS Ion Catcher
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-31T02%3A06%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Recent%20Upgrades%20of%20the%20Gas%20Handling%20System%20for%20the%20Cryogenic%20Stopping%20Cell%20of%20the%20FRS%20Ion%20Catcher&rft.jtitle=arXiv.org&rft.au=Mollaebrahimi,%20A&rft.date=2023-07-25&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.2307.15080&rft_dat=%3Cproquest%3E2843960598%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a950-5feff2674bed841aa94cfe4afe50e19820d73a54c66f36274956af5287e3c08e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2843960598&rft_id=info:pmid/&rfr_iscdi=true