Loading…

Was tun bei degenerierten Aortenklappenprothesen?

Originalpublikation Attias D, Nejjari M, Nappi F, Dreyfus J, Eleid MF, Rihal CS (2018) How to treat severe symptomatic structural valve deterioration of aortic surgical bioprosthesis: transcatheter valve-in-valve implantation or redo valve surgery? Die Entwicklung des „Transcatheter-valve-in-valve“-...

Full description

Saved in:
Bibliographic Details
Published in:Zeitschrift für Herz-, Thorax- und Gefässchirurgie Thorax- und Gefässchirurgie, 2019-04, Vol.33 (2), p.105-106
Main Author: Hartrumpf, M
Format: Article
Language:ger
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 106
container_issue 2
container_start_page 105
container_title Zeitschrift für Herz-, Thorax- und Gefässchirurgie
container_volume 33
creator Hartrumpf, M
description Originalpublikation Attias D, Nejjari M, Nappi F, Dreyfus J, Eleid MF, Rihal CS (2018) How to treat severe symptomatic structural valve deterioration of aortic surgical bioprosthesis: transcatheter valve-in-valve implantation or redo valve surgery? Die Entwicklung des „Transcatheter-valve-in-valve“-Verfahrens (TVIV) begünstigt diese Strategie. Die Literatur-Datenbanken PubMed, EMBASE, CINAHL und Cochrane wurden nach passenden Artikeln (2001–2017) durchsucht. [...]entstehen Patientenkarrieren mit z. T. mehrfachen Valve-in-valve-Prozeduren, bei denen die offene Reoperation und auch eine dauerhafte Antikoagulation vermieden werden. Neue Bioprothesen (Inspiris™ Resilia™, Edwards Lifesciences, Irvine, CA, USA) wurden hierfür entwickelt. Ein interventioneller Therapieversuch (Valve-in-valve) ist meist gerechtfertigt und verbaut nicht den Weg zu einer Reoperation. Transcatheter aortic valve replacement in intermediate and low risk patients-clinical evidence. Ferrari, E; Franciosi, G; Clivio, S; Faletra, F; Moccetti, M; Moccetti, T; Pedrazzini, G; Demertzis, S. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch. Hemodynamic performance of endovascular valves as valve-in-valve in small stented bioprosthesis.
doi_str_mv 10.1007/s00398-018-0288-9
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_2917899142</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2917899142</sourcerecordid><originalsourceid>FETCH-proquest_journals_29178991423</originalsourceid><addsrcrecordid>eNqNi0sKwjAURR-iYP0swFnAcfQlaUkyEhHFBQgOS8Wntkpak3T_RnABDi5ncM8BWAhcCUS9DojKGo4iTRrD7QAykauCC6n1EDK0CrmVshjDJIQGU5PrIgNxrgKLvWMXqtmV7uTI1-QjObZtv3i-qq4j1_k2PiiQ28xgdKtegeY_TmF52J92R56Ud08hlk3be5euUlqhjbUil-o_6wO2uDqg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2917899142</pqid></control><display><type>article</type><title>Was tun bei degenerierten Aortenklappenprothesen?</title><source>Springer Nature</source><creator>Hartrumpf, M</creator><creatorcontrib>Hartrumpf, M</creatorcontrib><description>Originalpublikation Attias D, Nejjari M, Nappi F, Dreyfus J, Eleid MF, Rihal CS (2018) How to treat severe symptomatic structural valve deterioration of aortic surgical bioprosthesis: transcatheter valve-in-valve implantation or redo valve surgery? Die Entwicklung des „Transcatheter-valve-in-valve“-Verfahrens (TVIV) begünstigt diese Strategie. Die Literatur-Datenbanken PubMed, EMBASE, CINAHL und Cochrane wurden nach passenden Artikeln (2001–2017) durchsucht. [...]entstehen Patientenkarrieren mit z. T. mehrfachen Valve-in-valve-Prozeduren, bei denen die offene Reoperation und auch eine dauerhafte Antikoagulation vermieden werden. Neue Bioprothesen (Inspiris™ Resilia™, Edwards Lifesciences, Irvine, CA, USA) wurden hierfür entwickelt. Ein interventioneller Therapieversuch (Valve-in-valve) ist meist gerechtfertigt und verbaut nicht den Weg zu einer Reoperation. Transcatheter aortic valve replacement in intermediate and low risk patients-clinical evidence. Ferrari, E; Franciosi, G; Clivio, S; Faletra, F; Moccetti, M; Moccetti, T; Pedrazzini, G; Demertzis, S. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch. Hemodynamic performance of endovascular valves as valve-in-valve in small stented bioprosthesis.</description><identifier>ISSN: 0930-9225</identifier><identifier>EISSN: 1435-1277</identifier><identifier>DOI: 10.1007/s00398-018-0288-9</identifier><language>ger</language><publisher>Heidelberg: Springer Nature B.V</publisher><subject>Heart</subject><ispartof>Zeitschrift für Herz-, Thorax- und Gefässchirurgie, 2019-04, Vol.33 (2), p.105-106</ispartof><rights>Springer Medizin Verlag GmbH, ein Teil von Springer Nature 2019.</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Hartrumpf, M</creatorcontrib><title>Was tun bei degenerierten Aortenklappenprothesen?</title><title>Zeitschrift für Herz-, Thorax- und Gefässchirurgie</title><description>Originalpublikation Attias D, Nejjari M, Nappi F, Dreyfus J, Eleid MF, Rihal CS (2018) How to treat severe symptomatic structural valve deterioration of aortic surgical bioprosthesis: transcatheter valve-in-valve implantation or redo valve surgery? Die Entwicklung des „Transcatheter-valve-in-valve“-Verfahrens (TVIV) begünstigt diese Strategie. Die Literatur-Datenbanken PubMed, EMBASE, CINAHL und Cochrane wurden nach passenden Artikeln (2001–2017) durchsucht. [...]entstehen Patientenkarrieren mit z. T. mehrfachen Valve-in-valve-Prozeduren, bei denen die offene Reoperation und auch eine dauerhafte Antikoagulation vermieden werden. Neue Bioprothesen (Inspiris™ Resilia™, Edwards Lifesciences, Irvine, CA, USA) wurden hierfür entwickelt. Ein interventioneller Therapieversuch (Valve-in-valve) ist meist gerechtfertigt und verbaut nicht den Weg zu einer Reoperation. Transcatheter aortic valve replacement in intermediate and low risk patients-clinical evidence. Ferrari, E; Franciosi, G; Clivio, S; Faletra, F; Moccetti, M; Moccetti, T; Pedrazzini, G; Demertzis, S. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch. Hemodynamic performance of endovascular valves as valve-in-valve in small stented bioprosthesis.</description><subject>Heart</subject><issn>0930-9225</issn><issn>1435-1277</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqNi0sKwjAURR-iYP0swFnAcfQlaUkyEhHFBQgOS8Wntkpak3T_RnABDi5ncM8BWAhcCUS9DojKGo4iTRrD7QAykauCC6n1EDK0CrmVshjDJIQGU5PrIgNxrgKLvWMXqtmV7uTI1-QjObZtv3i-qq4j1_k2PiiQ28xgdKtegeY_TmF52J92R56Ud08hlk3be5euUlqhjbUil-o_6wO2uDqg</recordid><startdate>20190401</startdate><enddate>20190401</enddate><creator>Hartrumpf, M</creator><general>Springer Nature B.V</general><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20190401</creationdate><title>Was tun bei degenerierten Aortenklappenprothesen?</title><author>Hartrumpf, M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_29178991423</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>ger</language><creationdate>2019</creationdate><topic>Heart</topic><toplevel>online_resources</toplevel><creatorcontrib>Hartrumpf, M</creatorcontrib><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Zeitschrift für Herz-, Thorax- und Gefässchirurgie</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hartrumpf, M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Was tun bei degenerierten Aortenklappenprothesen?</atitle><jtitle>Zeitschrift für Herz-, Thorax- und Gefässchirurgie</jtitle><date>2019-04-01</date><risdate>2019</risdate><volume>33</volume><issue>2</issue><spage>105</spage><epage>106</epage><pages>105-106</pages><issn>0930-9225</issn><eissn>1435-1277</eissn><abstract>Originalpublikation Attias D, Nejjari M, Nappi F, Dreyfus J, Eleid MF, Rihal CS (2018) How to treat severe symptomatic structural valve deterioration of aortic surgical bioprosthesis: transcatheter valve-in-valve implantation or redo valve surgery? Die Entwicklung des „Transcatheter-valve-in-valve“-Verfahrens (TVIV) begünstigt diese Strategie. Die Literatur-Datenbanken PubMed, EMBASE, CINAHL und Cochrane wurden nach passenden Artikeln (2001–2017) durchsucht. [...]entstehen Patientenkarrieren mit z. T. mehrfachen Valve-in-valve-Prozeduren, bei denen die offene Reoperation und auch eine dauerhafte Antikoagulation vermieden werden. Neue Bioprothesen (Inspiris™ Resilia™, Edwards Lifesciences, Irvine, CA, USA) wurden hierfür entwickelt. Ein interventioneller Therapieversuch (Valve-in-valve) ist meist gerechtfertigt und verbaut nicht den Weg zu einer Reoperation. Transcatheter aortic valve replacement in intermediate and low risk patients-clinical evidence. Ferrari, E; Franciosi, G; Clivio, S; Faletra, F; Moccetti, M; Moccetti, T; Pedrazzini, G; Demertzis, S. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch. Hemodynamic performance of endovascular valves as valve-in-valve in small stented bioprosthesis.</abstract><cop>Heidelberg</cop><pub>Springer Nature B.V</pub><doi>10.1007/s00398-018-0288-9</doi></addata></record>
fulltext fulltext
identifier ISSN: 0930-9225
ispartof Zeitschrift für Herz-, Thorax- und Gefässchirurgie, 2019-04, Vol.33 (2), p.105-106
issn 0930-9225
1435-1277
language ger
recordid cdi_proquest_journals_2917899142
source Springer Nature
subjects Heart
title Was tun bei degenerierten Aortenklappenprothesen?
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T20%3A32%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Was%20tun%20bei%20degenerierten%20Aortenklappenprothesen?&rft.jtitle=Zeitschrift%20f%C3%BCr%20Herz-,%20Thorax-%20und%20Gef%C3%A4sschirurgie&rft.au=Hartrumpf,%20M&rft.date=2019-04-01&rft.volume=33&rft.issue=2&rft.spage=105&rft.epage=106&rft.pages=105-106&rft.issn=0930-9225&rft.eissn=1435-1277&rft_id=info:doi/10.1007/s00398-018-0288-9&rft_dat=%3Cproquest%3E2917899142%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_29178991423%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2917899142&rft_id=info:pmid/&rfr_iscdi=true