Loading…

Submicrosecond field-jump device for pulsed high-field ELDOR

A field-jump device for fast stepping the electron paramagnetic resonance magnetic field around 3.4 T during pulsed electron-electron double resonance experiments at W-band (95 GHz) is described. Field jumps up to ±160 G and submicrosecond times for the full field-jump cycle allow precession frequen...

Full description

Saved in:
Bibliographic Details
Published in:Applied magnetic resonance 2002-09, Vol.22 (3), p.369-386
Main Authors: Dubinskii, A. A., Grishin, Yu A., Savitsky, A. N., Möbius, K.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473
cites cdi_FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473
container_end_page 386
container_issue 3
container_start_page 369
container_title Applied magnetic resonance
container_volume 22
creator Dubinskii, A. A.
Grishin, Yu A.
Savitsky, A. N.
Möbius, K.
description A field-jump device for fast stepping the electron paramagnetic resonance magnetic field around 3.4 T during pulsed electron-electron double resonance experiments at W-band (95 GHz) is described. Field jumps up to ±160 G and submicrosecond times for the full field-jump cycle allow precession frequency transfer experiments to be made for the determination of the nanometer distance and the orientation of nitroxide spin-label pairs in disordered samples.
doi_str_mv 10.1007/BF03166118
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2918060341</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2918060341</sourcerecordid><originalsourceid>FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473</originalsourceid><addsrcrecordid>eNpFkEtLw0AUhQdRsFY3_oKAO2H03txJJgNutA8VAgUf6zCZh01omjhpBP-9qRVcncX5OIdzGLtEuEEAefuwBMI0RcyO2ARTJC4TkMdsAookVyTkKTvr-xoAkwzlhN29DmVTmdD2zrRbG_nKbSyvh6aLrPuqjIt8G6Ju2PTORuvqY81_iWiRz1cv5-zE69G5-NMpe18u3mZPPF89Ps_uc27iRO54iSbONJEi9MIJaw05pSFJtTGgS-WEkEYojRBbQabMfJygVJR5haURkqbs6pDbhfZzcP2uqNshbMfKIlaYQQokcKSuD9R-TR-cL7pQNTp8FwjF_p3i_x36AftzVSw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2918060341</pqid></control><display><type>article</type><title>Submicrosecond field-jump device for pulsed high-field ELDOR</title><source>Springer Link</source><creator>Dubinskii, A. A. ; Grishin, Yu A. ; Savitsky, A. N. ; Möbius, K.</creator><creatorcontrib>Dubinskii, A. A. ; Grishin, Yu A. ; Savitsky, A. N. ; Möbius, K.</creatorcontrib><description>A field-jump device for fast stepping the electron paramagnetic resonance magnetic field around 3.4 T during pulsed electron-electron double resonance experiments at W-band (95 GHz) is described. Field jumps up to ±160 G and submicrosecond times for the full field-jump cycle allow precession frequency transfer experiments to be made for the determination of the nanometer distance and the orientation of nitroxide spin-label pairs in disordered samples.</description><identifier>ISSN: 0937-9347</identifier><identifier>EISSN: 1613-7507</identifier><identifier>DOI: 10.1007/BF03166118</identifier><language>eng</language><publisher>Heidelberg: Springer Nature B.V</publisher><subject>Electron paramagnetic resonance</subject><ispartof>Applied magnetic resonance, 2002-09, Vol.22 (3), p.369-386</ispartof><rights>Springer 2002.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473</citedby><cites>FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Dubinskii, A. A.</creatorcontrib><creatorcontrib>Grishin, Yu A.</creatorcontrib><creatorcontrib>Savitsky, A. N.</creatorcontrib><creatorcontrib>Möbius, K.</creatorcontrib><title>Submicrosecond field-jump device for pulsed high-field ELDOR</title><title>Applied magnetic resonance</title><description>A field-jump device for fast stepping the electron paramagnetic resonance magnetic field around 3.4 T during pulsed electron-electron double resonance experiments at W-band (95 GHz) is described. Field jumps up to ±160 G and submicrosecond times for the full field-jump cycle allow precession frequency transfer experiments to be made for the determination of the nanometer distance and the orientation of nitroxide spin-label pairs in disordered samples.</description><subject>Electron paramagnetic resonance</subject><issn>0937-9347</issn><issn>1613-7507</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2002</creationdate><recordtype>article</recordtype><recordid>eNpFkEtLw0AUhQdRsFY3_oKAO2H03txJJgNutA8VAgUf6zCZh01omjhpBP-9qRVcncX5OIdzGLtEuEEAefuwBMI0RcyO2ARTJC4TkMdsAookVyTkKTvr-xoAkwzlhN29DmVTmdD2zrRbG_nKbSyvh6aLrPuqjIt8G6Ju2PTORuvqY81_iWiRz1cv5-zE69G5-NMpe18u3mZPPF89Ps_uc27iRO54iSbONJEi9MIJaw05pSFJtTGgS-WEkEYojRBbQabMfJygVJR5haURkqbs6pDbhfZzcP2uqNshbMfKIlaYQQokcKSuD9R-TR-cL7pQNTp8FwjF_p3i_x36AftzVSw</recordid><startdate>20020901</startdate><enddate>20020901</enddate><creator>Dubinskii, A. A.</creator><creator>Grishin, Yu A.</creator><creator>Savitsky, A. N.</creator><creator>Möbius, K.</creator><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7XB</scope><scope>88I</scope><scope>8FE</scope><scope>8FG</scope><scope>8FK</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>M2P</scope><scope>P5Z</scope><scope>P62</scope><scope>PDBOC</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope></search><sort><creationdate>20020901</creationdate><title>Submicrosecond field-jump device for pulsed high-field ELDOR</title><author>Dubinskii, A. A. ; Grishin, Yu A. ; Savitsky, A. N. ; Möbius, K.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2002</creationdate><topic>Electron paramagnetic resonance</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dubinskii, A. A.</creatorcontrib><creatorcontrib>Grishin, Yu A.</creatorcontrib><creatorcontrib>Savitsky, A. N.</creatorcontrib><creatorcontrib>Möbius, K.</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Science Journals</collection><collection>ProQuest advanced technologies &amp; aerospace journals</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Materials Science Collection</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><jtitle>Applied magnetic resonance</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dubinskii, A. A.</au><au>Grishin, Yu A.</au><au>Savitsky, A. N.</au><au>Möbius, K.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Submicrosecond field-jump device for pulsed high-field ELDOR</atitle><jtitle>Applied magnetic resonance</jtitle><date>2002-09-01</date><risdate>2002</risdate><volume>22</volume><issue>3</issue><spage>369</spage><epage>386</epage><pages>369-386</pages><issn>0937-9347</issn><eissn>1613-7507</eissn><abstract>A field-jump device for fast stepping the electron paramagnetic resonance magnetic field around 3.4 T during pulsed electron-electron double resonance experiments at W-band (95 GHz) is described. Field jumps up to ±160 G and submicrosecond times for the full field-jump cycle allow precession frequency transfer experiments to be made for the determination of the nanometer distance and the orientation of nitroxide spin-label pairs in disordered samples.</abstract><cop>Heidelberg</cop><pub>Springer Nature B.V</pub><doi>10.1007/BF03166118</doi><tpages>18</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0937-9347
ispartof Applied magnetic resonance, 2002-09, Vol.22 (3), p.369-386
issn 0937-9347
1613-7507
language eng
recordid cdi_proquest_journals_2918060341
source Springer Link
subjects Electron paramagnetic resonance
title Submicrosecond field-jump device for pulsed high-field ELDOR
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T04%3A20%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Submicrosecond%20field-jump%20device%20for%20pulsed%20high-field%20ELDOR&rft.jtitle=Applied%20magnetic%20resonance&rft.au=Dubinskii,%20A.%20A.&rft.date=2002-09-01&rft.volume=22&rft.issue=3&rft.spage=369&rft.epage=386&rft.pages=369-386&rft.issn=0937-9347&rft.eissn=1613-7507&rft_id=info:doi/10.1007/BF03166118&rft_dat=%3Cproquest_cross%3E2918060341%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c257t-b1c28a33931f4e4ddc3e9a056acc0ab9e447c49a102d43cb8f2517938f91bc473%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2918060341&rft_id=info:pmid/&rfr_iscdi=true