Comment on "Demonstration of Low dv/dt Class-Ф2 DC-DC Converter With 50% Duty Cycle"
The mentioned article (Liu et al., 2023) proposed the frequency-domain-based modified impedance tuning analysis method and its demonstration in designing a Class-Ф 2 dc-dc converter with low dv / dt at 50% switching duty cycle. However, there are two typos during deriving the critical duty cycle and...
Saved in:
Published in: | IEEE transactions on power electronics 2024-05, Vol.39 (5), p.5040-5040 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The mentioned article (Liu et al., 2023) proposed the frequency-domain-based modified impedance tuning analysis method and its demonstration in designing a Class-Ф 2 dc-dc converter with low dv / dt at 50% switching duty cycle. However, there are two typos during deriving the critical duty cycle and equivalent switching frequency of the established circuit model. In this article, we presents the corrections to avoid possible misleading to the readers. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2024.3367991 |