Loading…

Study on occupant thermal comfort and household energy use in Chhattisgarh using a questionnaire

Studies on thermal comfort are currently being conducted on Chhattisgarh’s rural residential buildings, which are renowned for their utilization of natural resources. In rural development, most houses are converted from traditional to modern houses. In this transition, thermal comfort level and ener...

Full description

Saved in:
Bibliographic Details
Main Authors: Pal, Chaman Lal, Netam, Nisha
Format: Conference Proceeding
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue 1
container_start_page
container_title
container_volume 3031
creator Pal, Chaman Lal
Netam, Nisha
description Studies on thermal comfort are currently being conducted on Chhattisgarh’s rural residential buildings, which are renowned for their utilization of natural resources. In rural development, most houses are converted from traditional to modern houses. In this transition, thermal comfort level and energy consumption also rapidly changes. A questionnaire survey was done across entire seasons to compare the results of the scientific investigation with user responses from occupants of Kutcha house (traditional) and Pucca house (modern). The result shows that, in the summer and monsoon, those living in pucca houses report feeling warmer than those in Kutcha. Wintertime temperatures in Kutcha homes are colder than those in Pucca homes. The findings also show that Chhattisgarh residents experience severe discomfort during the summer. According to the study, semi-detached homes are better and more comfortable in the winter than detached homes. This research adds to the expanding number of studies demonstrating that Chhattisgarh Kutcha homes are excellent at creating a suitable indoor climate and less energy consumption during the summer and monsoon seasons.
doi_str_mv 10.1063/5.0193844
format conference_proceeding
fullrecord <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_3049019372</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3049019372</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1684-4f628bbd2c900f16d3d535fdbf45da070ffbd4f199677000235d125ada71e6803</originalsourceid><addsrcrecordid>eNotkE1LAzEQhoMoWKsH_0HAm7B1svnaPUrxCwoeVPAWs5uku6VN1iR76L93a3saZnh55-FB6JbAgoCgD3wBpKYVY2doRjgnhRREnKMZQM2KktHvS3SV0gagrKWsZujnI49mj4PHoW3HQfuMc2fjTm9xG3YuxIy1N7gLY7Jd2BpsvY3rPZ5W3Hu87Dqdc5_WOnbTrfdrrPHvaFPug_e6j_YaXTi9TfbmNOfo6_npc_larN5f3paPq2IgomIFc6KsmsaUbQ3giDDUcMqdaRzjRoME5xrDHKlrISVM-JQbUnJttCRWVEDn6O7YO8TwD6A2YYx-eqkosPpgRZZT6v6YSm2f9QFSDbHf6bhXBNTBoOLqZJD-AeJ-Y3s</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype><pqid>3049019372</pqid></control><display><type>conference_proceeding</type><title>Study on occupant thermal comfort and household energy use in Chhattisgarh using a questionnaire</title><source>American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)</source><creator>Pal, Chaman Lal ; Netam, Nisha</creator><contributor>Rajagopalan, Narendran ; Natarajan, Sendhil Kumar ; Dhanusuraman, Ragupathy</contributor><creatorcontrib>Pal, Chaman Lal ; Netam, Nisha ; Rajagopalan, Narendran ; Natarajan, Sendhil Kumar ; Dhanusuraman, Ragupathy</creatorcontrib><description>Studies on thermal comfort are currently being conducted on Chhattisgarh’s rural residential buildings, which are renowned for their utilization of natural resources. In rural development, most houses are converted from traditional to modern houses. In this transition, thermal comfort level and energy consumption also rapidly changes. A questionnaire survey was done across entire seasons to compare the results of the scientific investigation with user responses from occupants of Kutcha house (traditional) and Pucca house (modern). The result shows that, in the summer and monsoon, those living in pucca houses report feeling warmer than those in Kutcha. Wintertime temperatures in Kutcha homes are colder than those in Pucca homes. The findings also show that Chhattisgarh residents experience severe discomfort during the summer. According to the study, semi-detached homes are better and more comfortable in the winter than detached homes. This research adds to the expanding number of studies demonstrating that Chhattisgarh Kutcha homes are excellent at creating a suitable indoor climate and less energy consumption during the summer and monsoon seasons.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0193844</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>Energy consumption ; Houses ; Monsoons ; Natural resources ; Questionnaires ; Residential buildings ; Residential energy ; Summer ; Thermal comfort</subject><ispartof>AIP conference proceedings, 2024, Vol.3031 (1)</ispartof><rights>Author(s)</rights><rights>2024 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>309,310,314,776,780,785,786,23909,23910,25118,27901,27902</link.rule.ids></links><search><contributor>Rajagopalan, Narendran</contributor><contributor>Natarajan, Sendhil Kumar</contributor><contributor>Dhanusuraman, Ragupathy</contributor><creatorcontrib>Pal, Chaman Lal</creatorcontrib><creatorcontrib>Netam, Nisha</creatorcontrib><title>Study on occupant thermal comfort and household energy use in Chhattisgarh using a questionnaire</title><title>AIP conference proceedings</title><description>Studies on thermal comfort are currently being conducted on Chhattisgarh’s rural residential buildings, which are renowned for their utilization of natural resources. In rural development, most houses are converted from traditional to modern houses. In this transition, thermal comfort level and energy consumption also rapidly changes. A questionnaire survey was done across entire seasons to compare the results of the scientific investigation with user responses from occupants of Kutcha house (traditional) and Pucca house (modern). The result shows that, in the summer and monsoon, those living in pucca houses report feeling warmer than those in Kutcha. Wintertime temperatures in Kutcha homes are colder than those in Pucca homes. The findings also show that Chhattisgarh residents experience severe discomfort during the summer. According to the study, semi-detached homes are better and more comfortable in the winter than detached homes. This research adds to the expanding number of studies demonstrating that Chhattisgarh Kutcha homes are excellent at creating a suitable indoor climate and less energy consumption during the summer and monsoon seasons.</description><subject>Energy consumption</subject><subject>Houses</subject><subject>Monsoons</subject><subject>Natural resources</subject><subject>Questionnaires</subject><subject>Residential buildings</subject><subject>Residential energy</subject><subject>Summer</subject><subject>Thermal comfort</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2024</creationdate><recordtype>conference_proceeding</recordtype><recordid>eNotkE1LAzEQhoMoWKsH_0HAm7B1svnaPUrxCwoeVPAWs5uku6VN1iR76L93a3saZnh55-FB6JbAgoCgD3wBpKYVY2doRjgnhRREnKMZQM2KktHvS3SV0gagrKWsZujnI49mj4PHoW3HQfuMc2fjTm9xG3YuxIy1N7gLY7Jd2BpsvY3rPZ5W3Hu87Dqdc5_WOnbTrfdrrPHvaFPug_e6j_YaXTi9TfbmNOfo6_npc_larN5f3paPq2IgomIFc6KsmsaUbQ3giDDUcMqdaRzjRoME5xrDHKlrISVM-JQbUnJttCRWVEDn6O7YO8TwD6A2YYx-eqkosPpgRZZT6v6YSm2f9QFSDbHf6bhXBNTBoOLqZJD-AeJ-Y3s</recordid><startdate>20240430</startdate><enddate>20240430</enddate><creator>Pal, Chaman Lal</creator><creator>Netam, Nisha</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20240430</creationdate><title>Study on occupant thermal comfort and household energy use in Chhattisgarh using a questionnaire</title><author>Pal, Chaman Lal ; Netam, Nisha</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1684-4f628bbd2c900f16d3d535fdbf45da070ffbd4f199677000235d125ada71e6803</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Energy consumption</topic><topic>Houses</topic><topic>Monsoons</topic><topic>Natural resources</topic><topic>Questionnaires</topic><topic>Residential buildings</topic><topic>Residential energy</topic><topic>Summer</topic><topic>Thermal comfort</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Pal, Chaman Lal</creatorcontrib><creatorcontrib>Netam, Nisha</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Pal, Chaman Lal</au><au>Netam, Nisha</au><au>Rajagopalan, Narendran</au><au>Natarajan, Sendhil Kumar</au><au>Dhanusuraman, Ragupathy</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Study on occupant thermal comfort and household energy use in Chhattisgarh using a questionnaire</atitle><btitle>AIP conference proceedings</btitle><date>2024-04-30</date><risdate>2024</risdate><volume>3031</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>Studies on thermal comfort are currently being conducted on Chhattisgarh’s rural residential buildings, which are renowned for their utilization of natural resources. In rural development, most houses are converted from traditional to modern houses. In this transition, thermal comfort level and energy consumption also rapidly changes. A questionnaire survey was done across entire seasons to compare the results of the scientific investigation with user responses from occupants of Kutcha house (traditional) and Pucca house (modern). The result shows that, in the summer and monsoon, those living in pucca houses report feeling warmer than those in Kutcha. Wintertime temperatures in Kutcha homes are colder than those in Pucca homes. The findings also show that Chhattisgarh residents experience severe discomfort during the summer. According to the study, semi-detached homes are better and more comfortable in the winter than detached homes. This research adds to the expanding number of studies demonstrating that Chhattisgarh Kutcha homes are excellent at creating a suitable indoor climate and less energy consumption during the summer and monsoon seasons.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0193844</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0094-243X
ispartof AIP conference proceedings, 2024, Vol.3031 (1)
issn 0094-243X
1551-7616
language eng
recordid cdi_proquest_journals_3049019372
source American Institute of Physics:Jisc Collections:Transitional Journals Agreement 2021-23 (Reading list)
subjects Energy consumption
Houses
Monsoons
Natural resources
Questionnaires
Residential buildings
Residential energy
Summer
Thermal comfort
title Study on occupant thermal comfort and household energy use in Chhattisgarh using a questionnaire
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-06T02%3A56%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Study%20on%20occupant%20thermal%20comfort%20and%20household%20energy%20use%20in%20Chhattisgarh%20using%20a%20questionnaire&rft.btitle=AIP%20conference%20proceedings&rft.au=Pal,%20Chaman%20Lal&rft.date=2024-04-30&rft.volume=3031&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0193844&rft_dat=%3Cproquest_scita%3E3049019372%3C/proquest_scita%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p1684-4f628bbd2c900f16d3d535fdbf45da070ffbd4f199677000235d125ada71e6803%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3049019372&rft_id=info:pmid/&rfr_iscdi=true