Loading…

Geothermal Heat Pump for Space Cooling and Heating in Kuwaiti Climate

Kuwait stands as one of the hottest locations globally, experiencing scorching temperatures that can soar to 50 °C during the summer months. Conversely, in the winter months of December and January, temperatures may plummet to less than 10 °C. Maintaining a comfortable temperature indoors necessitat...

Full description

Saved in:
Bibliographic Details
Published in:Processes 2024-05, Vol.12 (5), p.910
Main Authors: Gharbia, Yousef, Derakhshandeh, Javad Farrokhi, Amer, A. M., Dinc, Ali
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Kuwait stands as one of the hottest locations globally, experiencing scorching temperatures that can soar to 50 °C during the summer months. Conversely, in the winter months of December and January, temperatures may plummet to less than 10 °C. Maintaining a comfortable temperature indoors necessitates a substantial amount of energy, particularly during the scorching summer seasons. In Kuwait, most of the electrical energy required for functions such as air conditioning and lighting is derived from fossil fuel resources, contributing to escalating air pollution and global warming. To reduce dependence on conventional energy sources for heating and cooling, this article presents a case study to explore the potential of using geothermal energy for space heating and cooling in Kuwait. The case study involves utilizing a geothermal heat pump (water-sourced heat pump) in conjunction with a vertical-borehole ground heat exchanger (VBGHE). The mentioned system is deployed to regulate the climate in a six-floor apartment block comprising a small two-bedroom apartment on each level, each with a total floor area of 57 m2. Two geothermal heat pumps, each with a cooling capacity of 2.58 kW and a heating capacity of 2.90 kW, connected to two vertical-borehole heat exchangers, were deployed for each apartment to maintain temperatures at 22 °C in winter and 26 °C in summer. The findings indicate that the estimated annual energy loads for cooling and heating for the apartment block are 42,758 kWh and 113 kWh, respectively. The corresponding electrical energy consumption amounted to 9294 kWh for space cooling and 113 kWh for space heating. The observed peak cooling load was approximately 9300 kJ/h (2.58 kW) per apartment, resulting in a power density of 45 W/m2. Moreover, the HP system achieved a 22% reduction in annual electric energy consumption compared to conventional air conditioning systems. This reduction in electric energy usage led to an annual CO2 reduction of 6.6 kg/m2.
ISSN:2227-9717
2227-9717
DOI:10.3390/pr12050910