Loading…

Comparison of Testosterone Extraction from Human Plasma Using MOFs (MIL-53(Al) and ZIF-8)-Based D-µ-SPE Coupled to HPLC–UV

A novel technique utilizing metal–organic frameworks (MOFs), namely MIL-53(Al) and ZIF-8, has been developed for the extraction of testosterone from human plasma through dispersive micro-solid phase extraction (D-µ-SPE or DMSPE). The synthesized MOFs were subjected to characterization via Fourier tr...

Full description

Saved in:
Bibliographic Details
Published in:Chromatographia 2024, Vol.87 (6), p.385-398
Main Authors: Akbari, Somaye, Takhvar, Azra, Souri, Effat, Ahmadkhaniha, Reza, Morsali, Ali, Khoshayand, Mohammad Reza, Amini, Mohsen, Taheri, Alireza
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c270t-a6012e14f139196031e9575816a8db185e7c3accfe2edbc35425fbc8bfd4b8793
container_end_page 398
container_issue 6
container_start_page 385
container_title Chromatographia
container_volume 87
creator Akbari, Somaye
Takhvar, Azra
Souri, Effat
Ahmadkhaniha, Reza
Morsali, Ali
Khoshayand, Mohammad Reza
Amini, Mohsen
Taheri, Alireza
description A novel technique utilizing metal–organic frameworks (MOFs), namely MIL-53(Al) and ZIF-8, has been developed for the extraction of testosterone from human plasma through dispersive micro-solid phase extraction (D-µ-SPE or DMSPE). The synthesized MOFs were subjected to characterization via Fourier transform infrared spectroscopy (FT-IR), powder X-ray diffraction (PXRD), and scanning electron microscopy (SEM). The parameters affecting the extraction were optimized by response surface methodology (RSM). The optimal extraction conditions were determined to be 15 min for contact time, 1 mg for MIL-53(Al) amount, and 0.23% (w/v) for NaCl concentration. For ZIF-8, a contact time of 22 min, a sorbent amount of 5.4 mg, and a salt concentration of 0.34% (w/v) were obtained. Batch absorption studies were conducted to find appropriate kinetic and isotherm models. The results indicated that while testosterone absorption was favorable in both cases, MIL-53 (Al) had a higher absorption capacity than ZIF-8. Finally, the proposed method was subjected to analytical validation for determination of testosterone in plasma samples. Good analytical performance was achieved, including a dynamic range of 0.05–1 µg/mL using each of the sorbents. The precision (expressed as the relative standard deviation (RSD)) and accuracy (expressed as the percentage error) of the method for testosterone and MIL-53(Al) were found to be 3.40% and 2.79%, respectively, while for testosterone and ZIF-8, they were 4.24% and 4.22%, respectively. The method effectively extracted 97% and 96% of testosterone from spiked plasma samples using MIL-53(Al) and ZIF-8, respectively.
doi_str_mv 10.1007/s10337-024-04329-9
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3063095363</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3063095363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c270t-a6012e14f139196031e9575816a8db185e7c3accfe2edbc35425fbc8bfd4b8793</originalsourceid><addsrcrecordid>eNp9kE1OwzAQhS0EEqVwAVaW2JSFwT_587KEllZK1Uq0LNhYTuJUqZI42IkECyTuwFm4AEfhJKQEiR2r0cy890bzAXBO8BXB2L-2BDPmI0wdhB1GOeIHYEA8QhEhhB6CAcaYIzfg7BicWLvrWso9bwBeQ13W0uRWV1BncK1so22jjK4UnDw3RiZN3q0yo0s4a0tZwVUhbSnhxubVFi6WUwtHi3mEXDYaF5dQVil8nE9RcIlupFUpvEWfH-h-NYGhbuuiGzQazlZR-PX2vnk4BUeZLKw6-61DsJlO1uEMRcu7eTiOUEJ93CDpYUIVcTLCOOEeZkRx13cD4skgjUngKj9hMkkyRVUaJ8x1qJvFSRBnqRMHPmdDcNHn1kY_td2PYqdbU3UnBcMew9xlHutUtFclRltrVCZqk5fSvAiCxR6z6DGLDrP4wSz20aw32U5cbZX5i_7H9Q1mIn5x</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3063095363</pqid></control><display><type>article</type><title>Comparison of Testosterone Extraction from Human Plasma Using MOFs (MIL-53(Al) and ZIF-8)-Based D-µ-SPE Coupled to HPLC–UV</title><source>Springer Nature</source><creator>Akbari, Somaye ; Takhvar, Azra ; Souri, Effat ; Ahmadkhaniha, Reza ; Morsali, Ali ; Khoshayand, Mohammad Reza ; Amini, Mohsen ; Taheri, Alireza</creator><creatorcontrib>Akbari, Somaye ; Takhvar, Azra ; Souri, Effat ; Ahmadkhaniha, Reza ; Morsali, Ali ; Khoshayand, Mohammad Reza ; Amini, Mohsen ; Taheri, Alireza</creatorcontrib><description>A novel technique utilizing metal–organic frameworks (MOFs), namely MIL-53(Al) and ZIF-8, has been developed for the extraction of testosterone from human plasma through dispersive micro-solid phase extraction (D-µ-SPE or DMSPE). The synthesized MOFs were subjected to characterization via Fourier transform infrared spectroscopy (FT-IR), powder X-ray diffraction (PXRD), and scanning electron microscopy (SEM). The parameters affecting the extraction were optimized by response surface methodology (RSM). The optimal extraction conditions were determined to be 15 min for contact time, 1 mg for MIL-53(Al) amount, and 0.23% (w/v) for NaCl concentration. For ZIF-8, a contact time of 22 min, a sorbent amount of 5.4 mg, and a salt concentration of 0.34% (w/v) were obtained. Batch absorption studies were conducted to find appropriate kinetic and isotherm models. The results indicated that while testosterone absorption was favorable in both cases, MIL-53 (Al) had a higher absorption capacity than ZIF-8. Finally, the proposed method was subjected to analytical validation for determination of testosterone in plasma samples. Good analytical performance was achieved, including a dynamic range of 0.05–1 µg/mL using each of the sorbents. The precision (expressed as the relative standard deviation (RSD)) and accuracy (expressed as the percentage error) of the method for testosterone and MIL-53(Al) were found to be 3.40% and 2.79%, respectively, while for testosterone and ZIF-8, they were 4.24% and 4.22%, respectively. The method effectively extracted 97% and 96% of testosterone from spiked plasma samples using MIL-53(Al) and ZIF-8, respectively.</description><identifier>ISSN: 0009-5893</identifier><identifier>EISSN: 1612-1112</identifier><identifier>DOI: 10.1007/s10337-024-04329-9</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer Berlin Heidelberg</publisher><subject>Absorption ; Analytical Chemistry ; Blood plasma ; Chemistry ; Chemistry and Materials Science ; Chromatography ; Fourier transforms ; Infrared spectroscopy ; Laboratory Medicine ; Metal-organic frameworks ; Original ; Pharmacy ; Plasma ; Proteomics ; Response surface methodology ; Solid phases ; Sorbents ; Testosterone ; X ray powder diffraction</subject><ispartof>Chromatographia, 2024, Vol.87 (6), p.385-398</ispartof><rights>The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2024. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c270t-a6012e14f139196031e9575816a8db185e7c3accfe2edbc35425fbc8bfd4b8793</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Akbari, Somaye</creatorcontrib><creatorcontrib>Takhvar, Azra</creatorcontrib><creatorcontrib>Souri, Effat</creatorcontrib><creatorcontrib>Ahmadkhaniha, Reza</creatorcontrib><creatorcontrib>Morsali, Ali</creatorcontrib><creatorcontrib>Khoshayand, Mohammad Reza</creatorcontrib><creatorcontrib>Amini, Mohsen</creatorcontrib><creatorcontrib>Taheri, Alireza</creatorcontrib><title>Comparison of Testosterone Extraction from Human Plasma Using MOFs (MIL-53(Al) and ZIF-8)-Based D-µ-SPE Coupled to HPLC–UV</title><title>Chromatographia</title><addtitle>Chromatographia</addtitle><description>A novel technique utilizing metal–organic frameworks (MOFs), namely MIL-53(Al) and ZIF-8, has been developed for the extraction of testosterone from human plasma through dispersive micro-solid phase extraction (D-µ-SPE or DMSPE). The synthesized MOFs were subjected to characterization via Fourier transform infrared spectroscopy (FT-IR), powder X-ray diffraction (PXRD), and scanning electron microscopy (SEM). The parameters affecting the extraction were optimized by response surface methodology (RSM). The optimal extraction conditions were determined to be 15 min for contact time, 1 mg for MIL-53(Al) amount, and 0.23% (w/v) for NaCl concentration. For ZIF-8, a contact time of 22 min, a sorbent amount of 5.4 mg, and a salt concentration of 0.34% (w/v) were obtained. Batch absorption studies were conducted to find appropriate kinetic and isotherm models. The results indicated that while testosterone absorption was favorable in both cases, MIL-53 (Al) had a higher absorption capacity than ZIF-8. Finally, the proposed method was subjected to analytical validation for determination of testosterone in plasma samples. Good analytical performance was achieved, including a dynamic range of 0.05–1 µg/mL using each of the sorbents. The precision (expressed as the relative standard deviation (RSD)) and accuracy (expressed as the percentage error) of the method for testosterone and MIL-53(Al) were found to be 3.40% and 2.79%, respectively, while for testosterone and ZIF-8, they were 4.24% and 4.22%, respectively. The method effectively extracted 97% and 96% of testosterone from spiked plasma samples using MIL-53(Al) and ZIF-8, respectively.</description><subject>Absorption</subject><subject>Analytical Chemistry</subject><subject>Blood plasma</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Chromatography</subject><subject>Fourier transforms</subject><subject>Infrared spectroscopy</subject><subject>Laboratory Medicine</subject><subject>Metal-organic frameworks</subject><subject>Original</subject><subject>Pharmacy</subject><subject>Plasma</subject><subject>Proteomics</subject><subject>Response surface methodology</subject><subject>Solid phases</subject><subject>Sorbents</subject><subject>Testosterone</subject><subject>X ray powder diffraction</subject><issn>0009-5893</issn><issn>1612-1112</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kE1OwzAQhS0EEqVwAVaW2JSFwT_587KEllZK1Uq0LNhYTuJUqZI42IkECyTuwFm4AEfhJKQEiR2r0cy890bzAXBO8BXB2L-2BDPmI0wdhB1GOeIHYEA8QhEhhB6CAcaYIzfg7BicWLvrWso9bwBeQ13W0uRWV1BncK1so22jjK4UnDw3RiZN3q0yo0s4a0tZwVUhbSnhxubVFi6WUwtHi3mEXDYaF5dQVil8nE9RcIlupFUpvEWfH-h-NYGhbuuiGzQazlZR-PX2vnk4BUeZLKw6-61DsJlO1uEMRcu7eTiOUEJ93CDpYUIVcTLCOOEeZkRx13cD4skgjUngKj9hMkkyRVUaJ8x1qJvFSRBnqRMHPmdDcNHn1kY_td2PYqdbU3UnBcMew9xlHutUtFclRltrVCZqk5fSvAiCxR6z6DGLDrP4wSz20aw32U5cbZX5i_7H9Q1mIn5x</recordid><startdate>2024</startdate><enddate>2024</enddate><creator>Akbari, Somaye</creator><creator>Takhvar, Azra</creator><creator>Souri, Effat</creator><creator>Ahmadkhaniha, Reza</creator><creator>Morsali, Ali</creator><creator>Khoshayand, Mohammad Reza</creator><creator>Amini, Mohsen</creator><creator>Taheri, Alireza</creator><general>Springer Berlin Heidelberg</general><general>Springer Nature B.V</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2024</creationdate><title>Comparison of Testosterone Extraction from Human Plasma Using MOFs (MIL-53(Al) and ZIF-8)-Based D-µ-SPE Coupled to HPLC–UV</title><author>Akbari, Somaye ; Takhvar, Azra ; Souri, Effat ; Ahmadkhaniha, Reza ; Morsali, Ali ; Khoshayand, Mohammad Reza ; Amini, Mohsen ; Taheri, Alireza</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c270t-a6012e14f139196031e9575816a8db185e7c3accfe2edbc35425fbc8bfd4b8793</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Absorption</topic><topic>Analytical Chemistry</topic><topic>Blood plasma</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Chromatography</topic><topic>Fourier transforms</topic><topic>Infrared spectroscopy</topic><topic>Laboratory Medicine</topic><topic>Metal-organic frameworks</topic><topic>Original</topic><topic>Pharmacy</topic><topic>Plasma</topic><topic>Proteomics</topic><topic>Response surface methodology</topic><topic>Solid phases</topic><topic>Sorbents</topic><topic>Testosterone</topic><topic>X ray powder diffraction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Akbari, Somaye</creatorcontrib><creatorcontrib>Takhvar, Azra</creatorcontrib><creatorcontrib>Souri, Effat</creatorcontrib><creatorcontrib>Ahmadkhaniha, Reza</creatorcontrib><creatorcontrib>Morsali, Ali</creatorcontrib><creatorcontrib>Khoshayand, Mohammad Reza</creatorcontrib><creatorcontrib>Amini, Mohsen</creatorcontrib><creatorcontrib>Taheri, Alireza</creatorcontrib><collection>CrossRef</collection><jtitle>Chromatographia</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Akbari, Somaye</au><au>Takhvar, Azra</au><au>Souri, Effat</au><au>Ahmadkhaniha, Reza</au><au>Morsali, Ali</au><au>Khoshayand, Mohammad Reza</au><au>Amini, Mohsen</au><au>Taheri, Alireza</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Comparison of Testosterone Extraction from Human Plasma Using MOFs (MIL-53(Al) and ZIF-8)-Based D-µ-SPE Coupled to HPLC–UV</atitle><jtitle>Chromatographia</jtitle><stitle>Chromatographia</stitle><date>2024</date><risdate>2024</risdate><volume>87</volume><issue>6</issue><spage>385</spage><epage>398</epage><pages>385-398</pages><issn>0009-5893</issn><eissn>1612-1112</eissn><abstract>A novel technique utilizing metal–organic frameworks (MOFs), namely MIL-53(Al) and ZIF-8, has been developed for the extraction of testosterone from human plasma through dispersive micro-solid phase extraction (D-µ-SPE or DMSPE). The synthesized MOFs were subjected to characterization via Fourier transform infrared spectroscopy (FT-IR), powder X-ray diffraction (PXRD), and scanning electron microscopy (SEM). The parameters affecting the extraction were optimized by response surface methodology (RSM). The optimal extraction conditions were determined to be 15 min for contact time, 1 mg for MIL-53(Al) amount, and 0.23% (w/v) for NaCl concentration. For ZIF-8, a contact time of 22 min, a sorbent amount of 5.4 mg, and a salt concentration of 0.34% (w/v) were obtained. Batch absorption studies were conducted to find appropriate kinetic and isotherm models. The results indicated that while testosterone absorption was favorable in both cases, MIL-53 (Al) had a higher absorption capacity than ZIF-8. Finally, the proposed method was subjected to analytical validation for determination of testosterone in plasma samples. Good analytical performance was achieved, including a dynamic range of 0.05–1 µg/mL using each of the sorbents. The precision (expressed as the relative standard deviation (RSD)) and accuracy (expressed as the percentage error) of the method for testosterone and MIL-53(Al) were found to be 3.40% and 2.79%, respectively, while for testosterone and ZIF-8, they were 4.24% and 4.22%, respectively. The method effectively extracted 97% and 96% of testosterone from spiked plasma samples using MIL-53(Al) and ZIF-8, respectively.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer Berlin Heidelberg</pub><doi>10.1007/s10337-024-04329-9</doi><tpages>14</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0009-5893
ispartof Chromatographia, 2024, Vol.87 (6), p.385-398
issn 0009-5893
1612-1112
language eng
recordid cdi_proquest_journals_3063095363
source Springer Nature
subjects Absorption
Analytical Chemistry
Blood plasma
Chemistry
Chemistry and Materials Science
Chromatography
Fourier transforms
Infrared spectroscopy
Laboratory Medicine
Metal-organic frameworks
Original
Pharmacy
Plasma
Proteomics
Response surface methodology
Solid phases
Sorbents
Testosterone
X ray powder diffraction
title Comparison of Testosterone Extraction from Human Plasma Using MOFs (MIL-53(Al) and ZIF-8)-Based D-µ-SPE Coupled to HPLC–UV
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T17%3A59%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Comparison%20of%20Testosterone%20Extraction%20from%20Human%20Plasma%20Using%20MOFs%20(MIL-53(Al)%20and%20ZIF-8)-Based%20D-%C2%B5-SPE%20Coupled%20to%20HPLC%E2%80%93UV&rft.jtitle=Chromatographia&rft.au=Akbari,%20Somaye&rft.date=2024&rft.volume=87&rft.issue=6&rft.spage=385&rft.epage=398&rft.pages=385-398&rft.issn=0009-5893&rft.eissn=1612-1112&rft_id=info:doi/10.1007/s10337-024-04329-9&rft_dat=%3Cproquest_cross%3E3063095363%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c270t-a6012e14f139196031e9575816a8db185e7c3accfe2edbc35425fbc8bfd4b8793%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3063095363&rft_id=info:pmid/&rfr_iscdi=true