Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration
As developments of local production of cryogenic fluids on the Lunar or Martian surface progress, it is important to understand transient system responses to help with the balancing of process plant power and understanding system-level operations. During the Cryogenic Fluid In-situ Liquefaction for...
Saved in:
Published in: | IOP conference series. Materials Science and Engineering 2024-05, Vol.1301 (1), p.12010 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c288t-9dfbb5fa10f3841f2c8be99a99929b389cd2aad700783e58d33d196ff0b7ab7e3 |
container_end_page | |
container_issue | 1 |
container_start_page | 12010 |
container_title | IOP conference series. Materials Science and Engineering |
container_volume | 1301 |
creator | Johnson, W L Balasubramaniam, R Grotenrath, R J Giddens, P A Smith, J W |
description | As developments of local production of cryogenic fluids on the Lunar or Martian surface progress, it is important to understand transient system responses to help with the balancing of process plant power and understanding system-level operations. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, a series of transient oxygen liquefaction tests were completed. These tests included varying liquefaction flow rate, environmental temperature, tank fill level, and effective cryocooler lift while allowing the tank pressure to respond to the input controls. An additional transient test was run at the 90% fill level to determine the impact of injecting the gaseous oxygen at the bottom of the tank, allowing the vapor to bubble up through the liquid. Tests were run in a cyclical nature varying one variable at a time. The control variable was set in a manner to increase tank pressure for a period of time and then subsequently changed in a manner to decrease the tank pressure back to its original value with multiple cycles run for all tests. Tank pressure and system temperature responses were tracked as a function of time with an emphasis on repeatability. Results indicate that of the four variables tested, the environmental temperature is the least important. As expected, the bubbling of the liquefaction gas significantly decreased the pressurization and depressurization rates in the tank at the 90% full level. |
doi_str_mv | 10.1088/1757-899X/1301/1/012010 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3076284704</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3076284704</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-9dfbb5fa10f3841f2c8be99a99929b389cd2aad700783e58d33d196ff0b7ab7e3</originalsourceid><addsrcrecordid>eNqFkF1LwzAUhoMoOKe_wYBXXtSeNN2SXMr8hI4Jm-BdSNsEO7amJumF_96UykQQhEByyHPec3gQuiRwQ4DzlLAZS7gQbymhQFKSAsmAwBGaHH6OD29OTtGZ91uAOctzmKCXjVOtb3QbcNF89NqoKjS2xfGEd42LvlUOW4eXyoVGtXjdu4hovOq0UwOpdvhO723rw1ifoxOjdl5ffN9T9Ppwv1k8JcXq8XlxWyRVxnlIRG3KcmYUAUN5TkxW8VILoYQQmSgpF1WdKVUzAMapnvGa0pqIuTFQMlUyTafoasztnI17-yC3tndxHS8psHnGcwZ5pNhIVc5677SRnWv2yn1KAnLQJwcxcpAkB32SyFFf7LweOxvb_UQv1_e_OdnVJrL0D_a_CV_froBG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3076284704</pqid></control><display><type>article</type><title>Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>Free Full-Text Journals in Chemistry</source><creator>Johnson, W L ; Balasubramaniam, R ; Grotenrath, R J ; Giddens, P A ; Smith, J W</creator><creatorcontrib>Johnson, W L ; Balasubramaniam, R ; Grotenrath, R J ; Giddens, P A ; Smith, J W</creatorcontrib><description>As developments of local production of cryogenic fluids on the Lunar or Martian surface progress, it is important to understand transient system responses to help with the balancing of process plant power and understanding system-level operations. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, a series of transient oxygen liquefaction tests were completed. These tests included varying liquefaction flow rate, environmental temperature, tank fill level, and effective cryocooler lift while allowing the tank pressure to respond to the input controls. An additional transient test was run at the 90% fill level to determine the impact of injecting the gaseous oxygen at the bottom of the tank, allowing the vapor to bubble up through the liquid. Tests were run in a cyclical nature varying one variable at a time. The control variable was set in a manner to increase tank pressure for a period of time and then subsequently changed in a manner to decrease the tank pressure back to its original value with multiple cycles run for all tests. Tank pressure and system temperature responses were tracked as a function of time with an emphasis on repeatability. Results indicate that of the four variables tested, the environmental temperature is the least important. As expected, the bubbling of the liquefaction gas significantly decreased the pressurization and depressurization rates in the tank at the 90% full level.</description><identifier>ISSN: 1757-8981</identifier><identifier>EISSN: 1757-899X</identifier><identifier>DOI: 10.1088/1757-899X/1301/1/012010</identifier><language>eng</language><publisher>Bristol: IOP Publishing</publisher><subject>Cryogenic cooling ; Cryogenic fluids ; Effectiveness ; Liquefaction ; Mars surface ; Oxygen ; Pressure reduction</subject><ispartof>IOP conference series. Materials Science and Engineering, 2024-05, Vol.1301 (1), p.12010</ispartof><rights>Published under licence by IOP Publishing Ltd</rights><rights>Published under licence by IOP Publishing Ltd. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c288t-9dfbb5fa10f3841f2c8be99a99929b389cd2aad700783e58d33d196ff0b7ab7e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/3076284704?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25752,27923,27924,37011,44589</link.rule.ids></links><search><creatorcontrib>Johnson, W L</creatorcontrib><creatorcontrib>Balasubramaniam, R</creatorcontrib><creatorcontrib>Grotenrath, R J</creatorcontrib><creatorcontrib>Giddens, P A</creatorcontrib><creatorcontrib>Smith, J W</creatorcontrib><title>Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration</title><title>IOP conference series. Materials Science and Engineering</title><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><description>As developments of local production of cryogenic fluids on the Lunar or Martian surface progress, it is important to understand transient system responses to help with the balancing of process plant power and understanding system-level operations. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, a series of transient oxygen liquefaction tests were completed. These tests included varying liquefaction flow rate, environmental temperature, tank fill level, and effective cryocooler lift while allowing the tank pressure to respond to the input controls. An additional transient test was run at the 90% fill level to determine the impact of injecting the gaseous oxygen at the bottom of the tank, allowing the vapor to bubble up through the liquid. Tests were run in a cyclical nature varying one variable at a time. The control variable was set in a manner to increase tank pressure for a period of time and then subsequently changed in a manner to decrease the tank pressure back to its original value with multiple cycles run for all tests. Tank pressure and system temperature responses were tracked as a function of time with an emphasis on repeatability. Results indicate that of the four variables tested, the environmental temperature is the least important. As expected, the bubbling of the liquefaction gas significantly decreased the pressurization and depressurization rates in the tank at the 90% full level.</description><subject>Cryogenic cooling</subject><subject>Cryogenic fluids</subject><subject>Effectiveness</subject><subject>Liquefaction</subject><subject>Mars surface</subject><subject>Oxygen</subject><subject>Pressure reduction</subject><issn>1757-8981</issn><issn>1757-899X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqFkF1LwzAUhoMoOKe_wYBXXtSeNN2SXMr8hI4Jm-BdSNsEO7amJumF_96UykQQhEByyHPec3gQuiRwQ4DzlLAZS7gQbymhQFKSAsmAwBGaHH6OD29OTtGZ91uAOctzmKCXjVOtb3QbcNF89NqoKjS2xfGEd42LvlUOW4eXyoVGtXjdu4hovOq0UwOpdvhO723rw1ifoxOjdl5ffN9T9Ppwv1k8JcXq8XlxWyRVxnlIRG3KcmYUAUN5TkxW8VILoYQQmSgpF1WdKVUzAMapnvGa0pqIuTFQMlUyTafoasztnI17-yC3tndxHS8psHnGcwZ5pNhIVc5677SRnWv2yn1KAnLQJwcxcpAkB32SyFFf7LweOxvb_UQv1_e_OdnVJrL0D_a_CV_froBG</recordid><startdate>20240501</startdate><enddate>20240501</enddate><creator>Johnson, W L</creator><creator>Balasubramaniam, R</creator><creator>Grotenrath, R J</creator><creator>Giddens, P A</creator><creator>Smith, J W</creator><general>IOP Publishing</general><scope>O3W</scope><scope>TSCCA</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L6V</scope><scope>M7S</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20240501</creationdate><title>Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration</title><author>Johnson, W L ; Balasubramaniam, R ; Grotenrath, R J ; Giddens, P A ; Smith, J W</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-9dfbb5fa10f3841f2c8be99a99929b389cd2aad700783e58d33d196ff0b7ab7e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Cryogenic cooling</topic><topic>Cryogenic fluids</topic><topic>Effectiveness</topic><topic>Liquefaction</topic><topic>Mars surface</topic><topic>Oxygen</topic><topic>Pressure reduction</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Johnson, W L</creatorcontrib><creatorcontrib>Balasubramaniam, R</creatorcontrib><creatorcontrib>Grotenrath, R J</creatorcontrib><creatorcontrib>Giddens, P A</creatorcontrib><creatorcontrib>Smith, J W</creatorcontrib><collection>Open Access: IOP Publishing Free Content</collection><collection>IOPscience (Open Access)</collection><collection>CrossRef</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><jtitle>IOP conference series. Materials Science and Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Johnson, W L</au><au>Balasubramaniam, R</au><au>Grotenrath, R J</au><au>Giddens, P A</au><au>Smith, J W</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration</atitle><jtitle>IOP conference series. Materials Science and Engineering</jtitle><addtitle>IOP Conf. Ser.: Mater. Sci. Eng</addtitle><date>2024-05-01</date><risdate>2024</risdate><volume>1301</volume><issue>1</issue><spage>12010</spage><pages>12010-</pages><issn>1757-8981</issn><eissn>1757-899X</eissn><abstract>As developments of local production of cryogenic fluids on the Lunar or Martian surface progress, it is important to understand transient system responses to help with the balancing of process plant power and understanding system-level operations. During the Cryogenic Fluid In-situ Liquefaction for Landers (CryoFILL) testing, a series of transient oxygen liquefaction tests were completed. These tests included varying liquefaction flow rate, environmental temperature, tank fill level, and effective cryocooler lift while allowing the tank pressure to respond to the input controls. An additional transient test was run at the 90% fill level to determine the impact of injecting the gaseous oxygen at the bottom of the tank, allowing the vapor to bubble up through the liquid. Tests were run in a cyclical nature varying one variable at a time. The control variable was set in a manner to increase tank pressure for a period of time and then subsequently changed in a manner to decrease the tank pressure back to its original value with multiple cycles run for all tests. Tank pressure and system temperature responses were tracked as a function of time with an emphasis on repeatability. Results indicate that of the four variables tested, the environmental temperature is the least important. As expected, the bubbling of the liquefaction gas significantly decreased the pressurization and depressurization rates in the tank at the 90% full level.</abstract><cop>Bristol</cop><pub>IOP Publishing</pub><doi>10.1088/1757-899X/1301/1/012010</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1757-8981 |
ispartof | IOP conference series. Materials Science and Engineering, 2024-05, Vol.1301 (1), p.12010 |
issn | 1757-8981 1757-899X |
language | eng |
recordid | cdi_proquest_journals_3076284704 |
source | Publicly Available Content Database (Proquest) (PQ_SDU_P3); Free Full-Text Journals in Chemistry |
subjects | Cryogenic cooling Cryogenic fluids Effectiveness Liquefaction Mars surface Oxygen Pressure reduction |
title | Transient Liquefaction on the Lunar or Martian Surface Operational Demonstration |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T16%3A08%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Transient%20Liquefaction%20on%20the%20Lunar%20or%20Martian%20Surface%20Operational%20Demonstration&rft.jtitle=IOP%20conference%20series.%20Materials%20Science%20and%20Engineering&rft.au=Johnson,%20W%20L&rft.date=2024-05-01&rft.volume=1301&rft.issue=1&rft.spage=12010&rft.pages=12010-&rft.issn=1757-8981&rft.eissn=1757-899X&rft_id=info:doi/10.1088/1757-899X/1301/1/012010&rft_dat=%3Cproquest_cross%3E3076284704%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c288t-9dfbb5fa10f3841f2c8be99a99929b389cd2aad700783e58d33d196ff0b7ab7e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3076284704&rft_id=info:pmid/&rfr_iscdi=true |