Loading…
Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant
Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The p...
Saved in:
Published in: | Water (Basel) 2024-07, Vol.16 (13), p.1892 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33 |
container_end_page | |
container_issue | 13 |
container_start_page | 1892 |
container_title | Water (Basel) |
container_volume | 16 |
creator | Chebil, Sabrine Ruiz-García, A. Farhat, Soumaya Bali, Mahmoud |
description | Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling. |
doi_str_mv | 10.3390/w16131892 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3079108354</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3079108354</sourcerecordid><originalsourceid>FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33</originalsourceid><addsrcrecordid>eNpNkE9LAzEQxYMoWGoPfoOAJw-r-be72aPWVoVCixY8LtM0227NJjXZrejFr25kRZzLPHi_eQMPoXNKrjgvyPU7zSinsmBHaMBIzhMhBD3-p0_RKIQdiSMKKVMyQF8zZzfJUvsGL7SvnG_AKo0nBzAdtLWzGOwaT11narvB4y14UK329WdvugoDnnbGJM8KjMa30X6twxa_QKTwkz5oHzSeh8aFOuA7HSAG9bcLA7Y9QycVmKBHv3uIltPJcvyQzOb3j-ObWaKoZG3CciGA5QXhKdMUuEhXIhe8YDKNslIAtKIklVqplVyJTClgsM6ynK8ZUZwP0UUfu_furdOhLXeu8zZ-LDnJC0okT0WkLntKeReC11W593UD_qOkpPxpuPxrmH8DsrxuAA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3079108354</pqid></control><display><type>article</type><title>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</title><source>Publicly Available Content Database</source><creator>Chebil, Sabrine ; Ruiz-García, A. ; Farhat, Soumaya ; Bali, Mahmoud</creator><creatorcontrib>Chebil, Sabrine ; Ruiz-García, A. ; Farhat, Soumaya ; Bali, Mahmoud</creatorcontrib><description>Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.</description><identifier>ISSN: 2073-4441</identifier><identifier>EISSN: 2073-4441</identifier><identifier>DOI: 10.3390/w16131892</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Aquifers ; Autopsies ; Brackish water ; Desalination ; Membranes ; Oxidation ; Permeability ; Seawater ; Standardization</subject><ispartof>Water (Basel), 2024-07, Vol.16 (13), p.1892</ispartof><rights>2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33</cites><orcidid>0000-0002-5288-9732 ; 0000-0002-5209-653X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/3079108354/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/3079108354?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,75126</link.rule.ids></links><search><creatorcontrib>Chebil, Sabrine</creatorcontrib><creatorcontrib>Ruiz-García, A.</creatorcontrib><creatorcontrib>Farhat, Soumaya</creatorcontrib><creatorcontrib>Bali, Mahmoud</creatorcontrib><title>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</title><title>Water (Basel)</title><description>Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.</description><subject>Aquifers</subject><subject>Autopsies</subject><subject>Brackish water</subject><subject>Desalination</subject><subject>Membranes</subject><subject>Oxidation</subject><subject>Permeability</subject><subject>Seawater</subject><subject>Standardization</subject><issn>2073-4441</issn><issn>2073-4441</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpNkE9LAzEQxYMoWGoPfoOAJw-r-be72aPWVoVCixY8LtM0227NJjXZrejFr25kRZzLPHi_eQMPoXNKrjgvyPU7zSinsmBHaMBIzhMhBD3-p0_RKIQdiSMKKVMyQF8zZzfJUvsGL7SvnG_AKo0nBzAdtLWzGOwaT11narvB4y14UK329WdvugoDnnbGJM8KjMa30X6twxa_QKTwkz5oHzSeh8aFOuA7HSAG9bcLA7Y9QycVmKBHv3uIltPJcvyQzOb3j-ObWaKoZG3CciGA5QXhKdMUuEhXIhe8YDKNslIAtKIklVqplVyJTClgsM6ynK8ZUZwP0UUfu_furdOhLXeu8zZ-LDnJC0okT0WkLntKeReC11W593UD_qOkpPxpuPxrmH8DsrxuAA</recordid><startdate>20240701</startdate><enddate>20240701</enddate><creator>Chebil, Sabrine</creator><creator>Ruiz-García, A.</creator><creator>Farhat, Soumaya</creator><creator>Bali, Mahmoud</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-5288-9732</orcidid><orcidid>https://orcid.org/0000-0002-5209-653X</orcidid></search><sort><creationdate>20240701</creationdate><title>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</title><author>Chebil, Sabrine ; Ruiz-García, A. ; Farhat, Soumaya ; Bali, Mahmoud</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aquifers</topic><topic>Autopsies</topic><topic>Brackish water</topic><topic>Desalination</topic><topic>Membranes</topic><topic>Oxidation</topic><topic>Permeability</topic><topic>Seawater</topic><topic>Standardization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chebil, Sabrine</creatorcontrib><creatorcontrib>Ruiz-García, A.</creatorcontrib><creatorcontrib>Farhat, Soumaya</creatorcontrib><creatorcontrib>Bali, Mahmoud</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Water (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chebil, Sabrine</au><au>Ruiz-García, A.</au><au>Farhat, Soumaya</au><au>Bali, Mahmoud</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</atitle><jtitle>Water (Basel)</jtitle><date>2024-07-01</date><risdate>2024</risdate><volume>16</volume><issue>13</issue><spage>1892</spage><pages>1892-</pages><issn>2073-4441</issn><eissn>2073-4441</eissn><abstract>Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/w16131892</doi><orcidid>https://orcid.org/0000-0002-5288-9732</orcidid><orcidid>https://orcid.org/0000-0002-5209-653X</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2073-4441 |
ispartof | Water (Basel), 2024-07, Vol.16 (13), p.1892 |
issn | 2073-4441 2073-4441 |
language | eng |
recordid | cdi_proquest_journals_3079108354 |
source | Publicly Available Content Database |
subjects | Aquifers Autopsies Brackish water Desalination Membranes Oxidation Permeability Seawater Standardization |
title | Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T21%3A03%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Long-Term%20Performance%20Evaluation%20and%20Fouling%20Characterization%20of%20a%20Full-Scale%20Brackish%20Water%20Reverse%20Osmosis%20Desalination%20Plant&rft.jtitle=Water%20(Basel)&rft.au=Chebil,%20Sabrine&rft.date=2024-07-01&rft.volume=16&rft.issue=13&rft.spage=1892&rft.pages=1892-&rft.issn=2073-4441&rft.eissn=2073-4441&rft_id=info:doi/10.3390/w16131892&rft_dat=%3Cproquest_cross%3E3079108354%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3079108354&rft_id=info:pmid/&rfr_iscdi=true |