Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant

Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The p...

Full description

Saved in:
Bibliographic Details
Published in:Water (Basel) 2024-07, Vol.16 (13), p.1892
Main Authors: Chebil, Sabrine, Ruiz-García, A., Farhat, Soumaya, Bali, Mahmoud
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33
container_end_page
container_issue 13
container_start_page 1892
container_title Water (Basel)
container_volume 16
creator Chebil, Sabrine
Ruiz-García, A.
Farhat, Soumaya
Bali, Mahmoud
description Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.
doi_str_mv 10.3390/w16131892
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3079108354</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3079108354</sourcerecordid><originalsourceid>FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33</originalsourceid><addsrcrecordid>eNpNkE9LAzEQxYMoWGoPfoOAJw-r-be72aPWVoVCixY8LtM0227NJjXZrejFr25kRZzLPHi_eQMPoXNKrjgvyPU7zSinsmBHaMBIzhMhBD3-p0_RKIQdiSMKKVMyQF8zZzfJUvsGL7SvnG_AKo0nBzAdtLWzGOwaT11narvB4y14UK329WdvugoDnnbGJM8KjMa30X6twxa_QKTwkz5oHzSeh8aFOuA7HSAG9bcLA7Y9QycVmKBHv3uIltPJcvyQzOb3j-ObWaKoZG3CciGA5QXhKdMUuEhXIhe8YDKNslIAtKIklVqplVyJTClgsM6ynK8ZUZwP0UUfu_furdOhLXeu8zZ-LDnJC0okT0WkLntKeReC11W593UD_qOkpPxpuPxrmH8DsrxuAA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3079108354</pqid></control><display><type>article</type><title>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</title><source>Publicly Available Content Database</source><creator>Chebil, Sabrine ; Ruiz-García, A. ; Farhat, Soumaya ; Bali, Mahmoud</creator><creatorcontrib>Chebil, Sabrine ; Ruiz-García, A. ; Farhat, Soumaya ; Bali, Mahmoud</creatorcontrib><description>Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.</description><identifier>ISSN: 2073-4441</identifier><identifier>EISSN: 2073-4441</identifier><identifier>DOI: 10.3390/w16131892</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Aquifers ; Autopsies ; Brackish water ; Desalination ; Membranes ; Oxidation ; Permeability ; Seawater ; Standardization</subject><ispartof>Water (Basel), 2024-07, Vol.16 (13), p.1892</ispartof><rights>2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33</cites><orcidid>0000-0002-5288-9732 ; 0000-0002-5209-653X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/3079108354/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/3079108354?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,75126</link.rule.ids></links><search><creatorcontrib>Chebil, Sabrine</creatorcontrib><creatorcontrib>Ruiz-García, A.</creatorcontrib><creatorcontrib>Farhat, Soumaya</creatorcontrib><creatorcontrib>Bali, Mahmoud</creatorcontrib><title>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</title><title>Water (Basel)</title><description>Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.</description><subject>Aquifers</subject><subject>Autopsies</subject><subject>Brackish water</subject><subject>Desalination</subject><subject>Membranes</subject><subject>Oxidation</subject><subject>Permeability</subject><subject>Seawater</subject><subject>Standardization</subject><issn>2073-4441</issn><issn>2073-4441</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpNkE9LAzEQxYMoWGoPfoOAJw-r-be72aPWVoVCixY8LtM0227NJjXZrejFr25kRZzLPHi_eQMPoXNKrjgvyPU7zSinsmBHaMBIzhMhBD3-p0_RKIQdiSMKKVMyQF8zZzfJUvsGL7SvnG_AKo0nBzAdtLWzGOwaT11narvB4y14UK329WdvugoDnnbGJM8KjMa30X6twxa_QKTwkz5oHzSeh8aFOuA7HSAG9bcLA7Y9QycVmKBHv3uIltPJcvyQzOb3j-ObWaKoZG3CciGA5QXhKdMUuEhXIhe8YDKNslIAtKIklVqplVyJTClgsM6ynK8ZUZwP0UUfu_furdOhLXeu8zZ-LDnJC0okT0WkLntKeReC11W593UD_qOkpPxpuPxrmH8DsrxuAA</recordid><startdate>20240701</startdate><enddate>20240701</enddate><creator>Chebil, Sabrine</creator><creator>Ruiz-García, A.</creator><creator>Farhat, Soumaya</creator><creator>Bali, Mahmoud</creator><general>MDPI AG</general><scope>AAYXX</scope><scope>CITATION</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><orcidid>https://orcid.org/0000-0002-5288-9732</orcidid><orcidid>https://orcid.org/0000-0002-5209-653X</orcidid></search><sort><creationdate>20240701</creationdate><title>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</title><author>Chebil, Sabrine ; Ruiz-García, A. ; Farhat, Soumaya ; Bali, Mahmoud</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Aquifers</topic><topic>Autopsies</topic><topic>Brackish water</topic><topic>Desalination</topic><topic>Membranes</topic><topic>Oxidation</topic><topic>Permeability</topic><topic>Seawater</topic><topic>Standardization</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chebil, Sabrine</creatorcontrib><creatorcontrib>Ruiz-García, A.</creatorcontrib><creatorcontrib>Farhat, Soumaya</creatorcontrib><creatorcontrib>Bali, Mahmoud</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>Water (Basel)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chebil, Sabrine</au><au>Ruiz-García, A.</au><au>Farhat, Soumaya</au><au>Bali, Mahmoud</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant</atitle><jtitle>Water (Basel)</jtitle><date>2024-07-01</date><risdate>2024</risdate><volume>16</volume><issue>13</issue><spage>1892</spage><pages>1892-</pages><issn>2073-4441</issn><eissn>2073-4441</eissn><abstract>Water scarcity in Tunisia’s semi-arid regions necessitates advanced brackish water desalination solutions. This study evaluates the long-term performance and fouling characteristics of the largest brackish water reverse osmosis desalination plant in southern Tunisia over a period of 5026 days. The plant employs two-stage spiral-wound membrane elements to treat groundwater with a salinity of 3.2 g L−1. The pre-treatment process includes oxidation, sand filtration, and cartridge filtration, along with polyphosphonate antiscalant dosing. Membrane performance was assessed through the analysis of operational data, standardization of permeate flow (Qps) and salt passage (SPs), and the calculation of water (A), solute (B), and ionic (Bj) permeability coefficients. Over the operational period, there was an increase in operating pressure, pressure drop, and permeate conductivity, accompanied by a gradual increase in SPs as well as in the solute B and ionic Bj permeability coefficients. The average B increased by 82%, reflecting a decrease in solute rejection over time. Additionally, the ionic permeability coefficients for both SO42− and Cl− ions increased, with Cl− showing an 88% increase and SO42− showing an 87% increase. The produced water’s salinity increased by 67%, indicating a significant loss of membrane performance. To identify the cause of these problems, membrane characterization was analyzed using visual inspection, X-ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR). The characterization revealed the complex nature of the foulants, with a predominant presence of calcium sulfate, along with minor quantities of calcite, dolomite, and silica. The extent of CaSO4 deposition suggests poor antiscaling efficiency, highlighting the critical importance of selecting an effective antiscalant to mitigate membrane fouling.</abstract><cop>Basel</cop><pub>MDPI AG</pub><doi>10.3390/w16131892</doi><orcidid>https://orcid.org/0000-0002-5288-9732</orcidid><orcidid>https://orcid.org/0000-0002-5209-653X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2073-4441
ispartof Water (Basel), 2024-07, Vol.16 (13), p.1892
issn 2073-4441
2073-4441
language eng
recordid cdi_proquest_journals_3079108354
source Publicly Available Content Database
subjects Aquifers
Autopsies
Brackish water
Desalination
Membranes
Oxidation
Permeability
Seawater
Standardization
title Long-Term Performance Evaluation and Fouling Characterization of a Full-Scale Brackish Water Reverse Osmosis Desalination Plant
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T21%3A03%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Long-Term%20Performance%20Evaluation%20and%20Fouling%20Characterization%20of%20a%20Full-Scale%20Brackish%20Water%20Reverse%20Osmosis%20Desalination%20Plant&rft.jtitle=Water%20(Basel)&rft.au=Chebil,%20Sabrine&rft.date=2024-07-01&rft.volume=16&rft.issue=13&rft.spage=1892&rft.pages=1892-&rft.issn=2073-4441&rft.eissn=2073-4441&rft_id=info:doi/10.3390/w16131892&rft_dat=%3Cproquest_cross%3E3079108354%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c182t-2744a2790352e1a345b4743928545bfcaa1f1058eccb8b46cca2ad6673d20c33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3079108354&rft_id=info:pmid/&rfr_iscdi=true