Loading…

Photon energy reconstruction with the MEG II liquid xenon calorimeter

The MEG II experiment searches for a charged-lepton-flavour-violating \(\mu \to e \gamma\) with the target sensitivity of \(6 \times 10^{-14}\). A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon ener...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2024-07
Main Authors: Yamamoto, Kensuke, Ban, Sei, Gerritzen, Lukas, Iwamoto, Toshiyuki, Kobayashi, Satoru, Matsushita, Ayaka, Mori, Toshinori, Onda, Rina, Ootani, Wataru, Oya, Atsushi
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Yamamoto, Kensuke
Ban, Sei
Gerritzen, Lukas
Iwamoto, Toshiyuki
Kobayashi, Satoru
Matsushita, Ayaka
Mori, Toshinori
Onda, Rina
Ootani, Wataru
Oya, Atsushi
description The MEG II experiment searches for a charged-lepton-flavour-violating \(\mu \to e \gamma\) with the target sensitivity of \(6 \times 10^{-14}\). A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is \(3\text{-}5 \times 10^{7}~\text{s}^{-1}\), multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of an energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_3086133949</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3086133949</sourcerecordid><originalsourceid>FETCH-proquest_journals_30861339493</originalsourceid><addsrcrecordid>eNqNisEKgkAUAJcgSMp_WOgsrPvU9BxWHoIO3UX0lSu2m7tvqf4-D31Ap4GZWbBAAsRRnki5YqFzgxBCZjuZphCw8tIbMpqjRnv_cIut0Y6sb0nN9qWo59QjP5dHXlV8VJNXHX-jnmPbjMaqBxLaDVvemtFh-OOabQ_ldX-KntZMHh3Vg_FWz6kGkWcxQJEU8N_1BYgEOvk</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3086133949</pqid></control><display><type>article</type><title>Photon energy reconstruction with the MEG II liquid xenon calorimeter</title><source>Publicly Available Content Database</source><creator>Yamamoto, Kensuke ; Ban, Sei ; Gerritzen, Lukas ; Iwamoto, Toshiyuki ; Kobayashi, Satoru ; Matsushita, Ayaka ; Mori, Toshinori ; Onda, Rina ; Ootani, Wataru ; Oya, Atsushi</creator><creatorcontrib>Yamamoto, Kensuke ; Ban, Sei ; Gerritzen, Lukas ; Iwamoto, Toshiyuki ; Kobayashi, Satoru ; Matsushita, Ayaka ; Mori, Toshinori ; Onda, Rina ; Ootani, Wataru ; Oya, Atsushi</creatorcontrib><description>The MEG II experiment searches for a charged-lepton-flavour-violating \(\mu \to e \gamma\) with the target sensitivity of \(6 \times 10^{-14}\). A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is \(3\text{-}5 \times 10^{7}~\text{s}^{-1}\), multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of an energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Calibration ; Flavors ; Leptons ; Muons ; Particle beams ; Photon beams ; Photons ; Position measurement ; Reconstruction ; Waveforms ; Xenon</subject><ispartof>arXiv.org, 2024-07</ispartof><rights>2024. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/3086133949?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25753,37012,44590</link.rule.ids></links><search><creatorcontrib>Yamamoto, Kensuke</creatorcontrib><creatorcontrib>Ban, Sei</creatorcontrib><creatorcontrib>Gerritzen, Lukas</creatorcontrib><creatorcontrib>Iwamoto, Toshiyuki</creatorcontrib><creatorcontrib>Kobayashi, Satoru</creatorcontrib><creatorcontrib>Matsushita, Ayaka</creatorcontrib><creatorcontrib>Mori, Toshinori</creatorcontrib><creatorcontrib>Onda, Rina</creatorcontrib><creatorcontrib>Ootani, Wataru</creatorcontrib><creatorcontrib>Oya, Atsushi</creatorcontrib><title>Photon energy reconstruction with the MEG II liquid xenon calorimeter</title><title>arXiv.org</title><description>The MEG II experiment searches for a charged-lepton-flavour-violating \(\mu \to e \gamma\) with the target sensitivity of \(6 \times 10^{-14}\). A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is \(3\text{-}5 \times 10^{7}~\text{s}^{-1}\), multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of an energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.</description><subject>Calibration</subject><subject>Flavors</subject><subject>Leptons</subject><subject>Muons</subject><subject>Particle beams</subject><subject>Photon beams</subject><subject>Photons</subject><subject>Position measurement</subject><subject>Reconstruction</subject><subject>Waveforms</subject><subject>Xenon</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNisEKgkAUAJcgSMp_WOgsrPvU9BxWHoIO3UX0lSu2m7tvqf4-D31Ap4GZWbBAAsRRnki5YqFzgxBCZjuZphCw8tIbMpqjRnv_cIut0Y6sb0nN9qWo59QjP5dHXlV8VJNXHX-jnmPbjMaqBxLaDVvemtFh-OOabQ_ldX-KntZMHh3Vg_FWz6kGkWcxQJEU8N_1BYgEOvk</recordid><startdate>20240728</startdate><enddate>20240728</enddate><creator>Yamamoto, Kensuke</creator><creator>Ban, Sei</creator><creator>Gerritzen, Lukas</creator><creator>Iwamoto, Toshiyuki</creator><creator>Kobayashi, Satoru</creator><creator>Matsushita, Ayaka</creator><creator>Mori, Toshinori</creator><creator>Onda, Rina</creator><creator>Ootani, Wataru</creator><creator>Oya, Atsushi</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20240728</creationdate><title>Photon energy reconstruction with the MEG II liquid xenon calorimeter</title><author>Yamamoto, Kensuke ; Ban, Sei ; Gerritzen, Lukas ; Iwamoto, Toshiyuki ; Kobayashi, Satoru ; Matsushita, Ayaka ; Mori, Toshinori ; Onda, Rina ; Ootani, Wataru ; Oya, Atsushi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_30861339493</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Calibration</topic><topic>Flavors</topic><topic>Leptons</topic><topic>Muons</topic><topic>Particle beams</topic><topic>Photon beams</topic><topic>Photons</topic><topic>Position measurement</topic><topic>Reconstruction</topic><topic>Waveforms</topic><topic>Xenon</topic><toplevel>online_resources</toplevel><creatorcontrib>Yamamoto, Kensuke</creatorcontrib><creatorcontrib>Ban, Sei</creatorcontrib><creatorcontrib>Gerritzen, Lukas</creatorcontrib><creatorcontrib>Iwamoto, Toshiyuki</creatorcontrib><creatorcontrib>Kobayashi, Satoru</creatorcontrib><creatorcontrib>Matsushita, Ayaka</creatorcontrib><creatorcontrib>Mori, Toshinori</creatorcontrib><creatorcontrib>Onda, Rina</creatorcontrib><creatorcontrib>Ootani, Wataru</creatorcontrib><creatorcontrib>Oya, Atsushi</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yamamoto, Kensuke</au><au>Ban, Sei</au><au>Gerritzen, Lukas</au><au>Iwamoto, Toshiyuki</au><au>Kobayashi, Satoru</au><au>Matsushita, Ayaka</au><au>Mori, Toshinori</au><au>Onda, Rina</au><au>Ootani, Wataru</au><au>Oya, Atsushi</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Photon energy reconstruction with the MEG II liquid xenon calorimeter</atitle><jtitle>arXiv.org</jtitle><date>2024-07-28</date><risdate>2024</risdate><eissn>2331-8422</eissn><abstract>The MEG II experiment searches for a charged-lepton-flavour-violating \(\mu \to e \gamma\) with the target sensitivity of \(6 \times 10^{-14}\). A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is \(3\text{-}5 \times 10^{7}~\text{s}^{-1}\), multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of an energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2024-07
issn 2331-8422
language eng
recordid cdi_proquest_journals_3086133949
source Publicly Available Content Database
subjects Calibration
Flavors
Leptons
Muons
Particle beams
Photon beams
Photons
Position measurement
Reconstruction
Waveforms
Xenon
title Photon energy reconstruction with the MEG II liquid xenon calorimeter
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T12%3A32%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Photon%20energy%20reconstruction%20with%20the%20MEG%20II%20liquid%20xenon%20calorimeter&rft.jtitle=arXiv.org&rft.au=Yamamoto,%20Kensuke&rft.date=2024-07-28&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E3086133949%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_30861339493%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3086133949&rft_id=info:pmid/&rfr_iscdi=true