Loading…

Does Ultrasound Really Good Enough to Evaluate the Pneumothorax in the Emergency Department

Thorax computed tomography in patients with thoracic trauma is undeniably a highly beneficial method. However, it also has disadvantages such as difficulties in transferring critical patients to computed tomography, delays in diagnosis, the risk of radiation exposure, and higher costs. On the other...

Full description

Saved in:
Bibliographic Details
Published in:Indian journal of surgery 2024-06, Vol.86 (3), p.526-533
Main Authors: Temel, Atilla, Doğan, Halil, Erduhan, Muge Arslan, Yigit, Yavuz
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83
cites cdi_FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83
container_end_page 533
container_issue 3
container_start_page 526
container_title Indian journal of surgery
container_volume 86
creator Temel, Atilla
Doğan, Halil
Erduhan, Muge Arslan
Yigit, Yavuz
description Thorax computed tomography in patients with thoracic trauma is undeniably a highly beneficial method. However, it also has disadvantages such as difficulties in transferring critical patients to computed tomography, delays in diagnosis, the risk of radiation exposure, and higher costs. On the other hand, ultrasonography can be rapidly performed at the bedside and is a non-invasive technique that poses no risk of radiation exposure. These advantages make it a valuable method in the early diagnosis of thoracic trauma. Therefore, this study aimed to provide insights into the sensitivity and accuracy of bedside ultrasonography in diagnosing pneumothorax in patients presenting with thorax trauma in an emergency department. The study sample comprised 132 patients over 18 years of age who were transferred with thorax trauma to the Emergency Clinic of Bakırköy Dr. Sadi Konuk Training and Research Hospital between January 30, 2015, and June 30, 2015. Ultrasonographic examinations were performed before thoracic computed tomography in all patients for whom a thorax computed tomography was indicated based on the clinical examination by the emergency room physician. The thoracic computed tomography reports, interpreted by a radiologist who was blinded to the ultrasonographic and clinical findings of the patients, were accepted as the gold standard. All 132 patients included in the study underwent Thorax ultrasonography. The average age of the patients was 76.5%, with the youngest patient being 18 years old and the oldest one being 90 years old. Of the patients, 45.38% ( n  = 101) were men. The results of Thorax ultrasonography showed that 19 patients had pneumothorax. These findings were then compared with the Thorax computed tomography results accepted as the gold standard. The results revealed that Thorax ultrasonography had a sensitivity of 56.2% and a specificity of 99% in detecting pneumothorax. According to the grading on CT, our observation revealed that the sensitivity of ultrasonography to detect pneumothorax increased proportionally with the severity of pneumothorax detected on thoracic computed tomography. The sensitivity of ultrasonography in patients with a grade 2 pneumothorax and those with a grade 3 pneumothorax, according to Thorax computed tomography, was found to be 70% and 100%, respectively. Thorax ultrasonography is a useful technique with high specificity in diagnosing pneumothorax, but its sensitivity decreases significantly when the size is bel
doi_str_mv 10.1007/s12262-023-03895-w
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_3087556424</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3087556424</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhhdRsFb_gKeA59VJss0mR2nXKhQUsScPIZudfrHd1CRr7b937QrePM0wPO878CTJNYVbCpDfBcqYYCkwngKXapTuT5IBqJynKlf89LizlIGQ58lFCBsAlgnOB8n7xGEg8zp6E1zbVOQVTV0fyNS5ihSNa5crEh0pPk3dmogkrpC8NNhuXVw5b77Iujneii36JTb2QCa4Mz5usYmXydnC1AGvfucwmT8Ub-PHdPY8fRrfz1LLBY-pVGgWUCopSpTWUkVVBhYMp9ZmVkgFlvIcS1qpUkg7qowSQE3JOZQIleTD5Kbv3Xn30WKIeuNa33QvNQeZj0YiY1lHsZ6y3oXgcaF3fr01_qAp6B-JupeoO4n6KFHvuxDvQ6GDmyX6v-p_Ut9j9XX1</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3087556424</pqid></control><display><type>article</type><title>Does Ultrasound Really Good Enough to Evaluate the Pneumothorax in the Emergency Department</title><source>Springer Nature</source><creator>Temel, Atilla ; Doğan, Halil ; Erduhan, Muge Arslan ; Yigit, Yavuz</creator><creatorcontrib>Temel, Atilla ; Doğan, Halil ; Erduhan, Muge Arslan ; Yigit, Yavuz</creatorcontrib><description>Thorax computed tomography in patients with thoracic trauma is undeniably a highly beneficial method. However, it also has disadvantages such as difficulties in transferring critical patients to computed tomography, delays in diagnosis, the risk of radiation exposure, and higher costs. On the other hand, ultrasonography can be rapidly performed at the bedside and is a non-invasive technique that poses no risk of radiation exposure. These advantages make it a valuable method in the early diagnosis of thoracic trauma. Therefore, this study aimed to provide insights into the sensitivity and accuracy of bedside ultrasonography in diagnosing pneumothorax in patients presenting with thorax trauma in an emergency department. The study sample comprised 132 patients over 18 years of age who were transferred with thorax trauma to the Emergency Clinic of Bakırköy Dr. Sadi Konuk Training and Research Hospital between January 30, 2015, and June 30, 2015. Ultrasonographic examinations were performed before thoracic computed tomography in all patients for whom a thorax computed tomography was indicated based on the clinical examination by the emergency room physician. The thoracic computed tomography reports, interpreted by a radiologist who was blinded to the ultrasonographic and clinical findings of the patients, were accepted as the gold standard. All 132 patients included in the study underwent Thorax ultrasonography. The average age of the patients was 76.5%, with the youngest patient being 18 years old and the oldest one being 90 years old. Of the patients, 45.38% ( n  = 101) were men. The results of Thorax ultrasonography showed that 19 patients had pneumothorax. These findings were then compared with the Thorax computed tomography results accepted as the gold standard. The results revealed that Thorax ultrasonography had a sensitivity of 56.2% and a specificity of 99% in detecting pneumothorax. According to the grading on CT, our observation revealed that the sensitivity of ultrasonography to detect pneumothorax increased proportionally with the severity of pneumothorax detected on thoracic computed tomography. The sensitivity of ultrasonography in patients with a grade 2 pneumothorax and those with a grade 3 pneumothorax, according to Thorax computed tomography, was found to be 70% and 100%, respectively. Thorax ultrasonography is a useful technique with high specificity in diagnosing pneumothorax, but its sensitivity decreases significantly when the size is below 1 cm.</description><identifier>ISSN: 0972-2068</identifier><identifier>EISSN: 0973-9793</identifier><identifier>DOI: 10.1007/s12262-023-03895-w</identifier><language>eng</language><publisher>New Delhi: Springer India</publisher><subject>Cardiac Surgery ; Emergency medical care ; Medicine ; Medicine &amp; Public Health ; Neurosurgery ; Original Article ; Pediatric Surgery ; Plastic Surgery ; Pneumothorax ; Radiation ; Surgery ; Thoracic Surgery ; Thorax ; Tomography ; Ultrasonic imaging</subject><ispartof>Indian journal of surgery, 2024-06, Vol.86 (3), p.526-533</ispartof><rights>The Author(s) 2023</rights><rights>The Author(s) 2023. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83</citedby><cites>FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83</cites><orcidid>0000-0002-7226-983X ; 0000-0002-0426-2142 ; 0000-0001-6518-7185 ; 0000-0003-4751-030X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Temel, Atilla</creatorcontrib><creatorcontrib>Doğan, Halil</creatorcontrib><creatorcontrib>Erduhan, Muge Arslan</creatorcontrib><creatorcontrib>Yigit, Yavuz</creatorcontrib><title>Does Ultrasound Really Good Enough to Evaluate the Pneumothorax in the Emergency Department</title><title>Indian journal of surgery</title><addtitle>Indian J Surg</addtitle><description>Thorax computed tomography in patients with thoracic trauma is undeniably a highly beneficial method. However, it also has disadvantages such as difficulties in transferring critical patients to computed tomography, delays in diagnosis, the risk of radiation exposure, and higher costs. On the other hand, ultrasonography can be rapidly performed at the bedside and is a non-invasive technique that poses no risk of radiation exposure. These advantages make it a valuable method in the early diagnosis of thoracic trauma. Therefore, this study aimed to provide insights into the sensitivity and accuracy of bedside ultrasonography in diagnosing pneumothorax in patients presenting with thorax trauma in an emergency department. The study sample comprised 132 patients over 18 years of age who were transferred with thorax trauma to the Emergency Clinic of Bakırköy Dr. Sadi Konuk Training and Research Hospital between January 30, 2015, and June 30, 2015. Ultrasonographic examinations were performed before thoracic computed tomography in all patients for whom a thorax computed tomography was indicated based on the clinical examination by the emergency room physician. The thoracic computed tomography reports, interpreted by a radiologist who was blinded to the ultrasonographic and clinical findings of the patients, were accepted as the gold standard. All 132 patients included in the study underwent Thorax ultrasonography. The average age of the patients was 76.5%, with the youngest patient being 18 years old and the oldest one being 90 years old. Of the patients, 45.38% ( n  = 101) were men. The results of Thorax ultrasonography showed that 19 patients had pneumothorax. These findings were then compared with the Thorax computed tomography results accepted as the gold standard. The results revealed that Thorax ultrasonography had a sensitivity of 56.2% and a specificity of 99% in detecting pneumothorax. According to the grading on CT, our observation revealed that the sensitivity of ultrasonography to detect pneumothorax increased proportionally with the severity of pneumothorax detected on thoracic computed tomography. The sensitivity of ultrasonography in patients with a grade 2 pneumothorax and those with a grade 3 pneumothorax, according to Thorax computed tomography, was found to be 70% and 100%, respectively. Thorax ultrasonography is a useful technique with high specificity in diagnosing pneumothorax, but its sensitivity decreases significantly when the size is below 1 cm.</description><subject>Cardiac Surgery</subject><subject>Emergency medical care</subject><subject>Medicine</subject><subject>Medicine &amp; Public Health</subject><subject>Neurosurgery</subject><subject>Original Article</subject><subject>Pediatric Surgery</subject><subject>Plastic Surgery</subject><subject>Pneumothorax</subject><subject>Radiation</subject><subject>Surgery</subject><subject>Thoracic Surgery</subject><subject>Thorax</subject><subject>Tomography</subject><subject>Ultrasonic imaging</subject><issn>0972-2068</issn><issn>0973-9793</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhhdRsFb_gKeA59VJss0mR2nXKhQUsScPIZudfrHd1CRr7b937QrePM0wPO878CTJNYVbCpDfBcqYYCkwngKXapTuT5IBqJynKlf89LizlIGQ58lFCBsAlgnOB8n7xGEg8zp6E1zbVOQVTV0fyNS5ihSNa5crEh0pPk3dmogkrpC8NNhuXVw5b77Iujneii36JTb2QCa4Mz5usYmXydnC1AGvfucwmT8Ub-PHdPY8fRrfz1LLBY-pVGgWUCopSpTWUkVVBhYMp9ZmVkgFlvIcS1qpUkg7qowSQE3JOZQIleTD5Kbv3Xn30WKIeuNa33QvNQeZj0YiY1lHsZ6y3oXgcaF3fr01_qAp6B-JupeoO4n6KFHvuxDvQ6GDmyX6v-p_Ut9j9XX1</recordid><startdate>20240601</startdate><enddate>20240601</enddate><creator>Temel, Atilla</creator><creator>Doğan, Halil</creator><creator>Erduhan, Muge Arslan</creator><creator>Yigit, Yavuz</creator><general>Springer India</general><general>Springer Nature B.V</general><scope>C6C</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><orcidid>https://orcid.org/0000-0002-7226-983X</orcidid><orcidid>https://orcid.org/0000-0002-0426-2142</orcidid><orcidid>https://orcid.org/0000-0001-6518-7185</orcidid><orcidid>https://orcid.org/0000-0003-4751-030X</orcidid></search><sort><creationdate>20240601</creationdate><title>Does Ultrasound Really Good Enough to Evaluate the Pneumothorax in the Emergency Department</title><author>Temel, Atilla ; Doğan, Halil ; Erduhan, Muge Arslan ; Yigit, Yavuz</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Cardiac Surgery</topic><topic>Emergency medical care</topic><topic>Medicine</topic><topic>Medicine &amp; Public Health</topic><topic>Neurosurgery</topic><topic>Original Article</topic><topic>Pediatric Surgery</topic><topic>Plastic Surgery</topic><topic>Pneumothorax</topic><topic>Radiation</topic><topic>Surgery</topic><topic>Thoracic Surgery</topic><topic>Thorax</topic><topic>Tomography</topic><topic>Ultrasonic imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Temel, Atilla</creatorcontrib><creatorcontrib>Doğan, Halil</creatorcontrib><creatorcontrib>Erduhan, Muge Arslan</creatorcontrib><creatorcontrib>Yigit, Yavuz</creatorcontrib><collection>Springer Nature OA Free Journals</collection><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><jtitle>Indian journal of surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Temel, Atilla</au><au>Doğan, Halil</au><au>Erduhan, Muge Arslan</au><au>Yigit, Yavuz</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Does Ultrasound Really Good Enough to Evaluate the Pneumothorax in the Emergency Department</atitle><jtitle>Indian journal of surgery</jtitle><stitle>Indian J Surg</stitle><date>2024-06-01</date><risdate>2024</risdate><volume>86</volume><issue>3</issue><spage>526</spage><epage>533</epage><pages>526-533</pages><issn>0972-2068</issn><eissn>0973-9793</eissn><abstract>Thorax computed tomography in patients with thoracic trauma is undeniably a highly beneficial method. However, it also has disadvantages such as difficulties in transferring critical patients to computed tomography, delays in diagnosis, the risk of radiation exposure, and higher costs. On the other hand, ultrasonography can be rapidly performed at the bedside and is a non-invasive technique that poses no risk of radiation exposure. These advantages make it a valuable method in the early diagnosis of thoracic trauma. Therefore, this study aimed to provide insights into the sensitivity and accuracy of bedside ultrasonography in diagnosing pneumothorax in patients presenting with thorax trauma in an emergency department. The study sample comprised 132 patients over 18 years of age who were transferred with thorax trauma to the Emergency Clinic of Bakırköy Dr. Sadi Konuk Training and Research Hospital between January 30, 2015, and June 30, 2015. Ultrasonographic examinations were performed before thoracic computed tomography in all patients for whom a thorax computed tomography was indicated based on the clinical examination by the emergency room physician. The thoracic computed tomography reports, interpreted by a radiologist who was blinded to the ultrasonographic and clinical findings of the patients, were accepted as the gold standard. All 132 patients included in the study underwent Thorax ultrasonography. The average age of the patients was 76.5%, with the youngest patient being 18 years old and the oldest one being 90 years old. Of the patients, 45.38% ( n  = 101) were men. The results of Thorax ultrasonography showed that 19 patients had pneumothorax. These findings were then compared with the Thorax computed tomography results accepted as the gold standard. The results revealed that Thorax ultrasonography had a sensitivity of 56.2% and a specificity of 99% in detecting pneumothorax. According to the grading on CT, our observation revealed that the sensitivity of ultrasonography to detect pneumothorax increased proportionally with the severity of pneumothorax detected on thoracic computed tomography. The sensitivity of ultrasonography in patients with a grade 2 pneumothorax and those with a grade 3 pneumothorax, according to Thorax computed tomography, was found to be 70% and 100%, respectively. Thorax ultrasonography is a useful technique with high specificity in diagnosing pneumothorax, but its sensitivity decreases significantly when the size is below 1 cm.</abstract><cop>New Delhi</cop><pub>Springer India</pub><doi>10.1007/s12262-023-03895-w</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-7226-983X</orcidid><orcidid>https://orcid.org/0000-0002-0426-2142</orcidid><orcidid>https://orcid.org/0000-0001-6518-7185</orcidid><orcidid>https://orcid.org/0000-0003-4751-030X</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0972-2068
ispartof Indian journal of surgery, 2024-06, Vol.86 (3), p.526-533
issn 0972-2068
0973-9793
language eng
recordid cdi_proquest_journals_3087556424
source Springer Nature
subjects Cardiac Surgery
Emergency medical care
Medicine
Medicine & Public Health
Neurosurgery
Original Article
Pediatric Surgery
Plastic Surgery
Pneumothorax
Radiation
Surgery
Thoracic Surgery
Thorax
Tomography
Ultrasonic imaging
title Does Ultrasound Really Good Enough to Evaluate the Pneumothorax in the Emergency Department
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T23%3A43%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Does%20Ultrasound%20Really%20Good%20Enough%20to%20Evaluate%20the%20Pneumothorax%20in%20the%20Emergency%20Department&rft.jtitle=Indian%20journal%20of%20surgery&rft.au=Temel,%20Atilla&rft.date=2024-06-01&rft.volume=86&rft.issue=3&rft.spage=526&rft.epage=533&rft.pages=526-533&rft.issn=0972-2068&rft.eissn=0973-9793&rft_id=info:doi/10.1007/s12262-023-03895-w&rft_dat=%3Cproquest_cross%3E3087556424%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c363t-89eaf0b986be8cc191940c0a31cc4c6890c137eb1d9b68c5da9601ab330be0d83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3087556424&rft_id=info:pmid/&rfr_iscdi=true