Loading…
An integrated evanescent-field biosensor in silicon
Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated ci...
Saved in:
Published in: | arXiv.org 2024-10 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Al-Qadasi, Mohammed A Grist, Samantha M Mitchell, Matthew Newton, Karyn Kioussis, Stephen Chowdhury, Sheri J Randhawa, Avineet Liu, Yifei Tisapramotkul, Piramon Cheung, Karen C Chrostowski, Lukas Shekhar, Sudip |
description | Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated circuits are a promising technology to meet this need, as they can leverage (1) semiconductor manufacturing economies of scale, (2) exquisite optical sensitivity, and (3) the ability to integrate tens to hundreds of sensors on a millimeter-scale photonic chip. However, their application to decentralized testing has historically been limited by the expensive, bulky tunable lasers and alignment optics required for their readout. In this work, we introduce a segmented sensor architecture that addresses this important challenge by facilitating resonance-tracking readout using a fixed-wavelength laser. The architecture incorporates an in-resonator phase shifter modulated by CMOS drivers to periodically sweep and acquire the resonance peak shifts as well as a distinct high-sensitivity sensing region, maintaining high performance at a fraction of the cost and size. We show, for the first time, that fixed-wavelength sensor readout can offer similar performance to traditional tunable laser readout, demonstrating a system limit of detection of 6.1 x 10-5 RIU as well as immunoassay-based detection of the SARS-CoV-2 spike protein. We anticipate that this sensor architecture will open the door to a new data-rich class of portable, accurate, multiplexed diagnostics for decentralized testing. |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_3109530610</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3109530610</sourcerecordid><originalsourceid>FETCH-proquest_journals_31095306103</originalsourceid><addsrcrecordid>eNqNykEKwjAQQNEgCBbtHQKuA0nGVF2KKB7AfYntVFLCRDOp57cLD-DqL_5biMoCGHXYWbsSNfOotbbN3joHlYATyUAFn9kX7CV-PCF3SEUNAWMvHyExEqc8K8khhi7RRiwHHxnrX9die73czzf1yuk9IZd2TFOmebVg9NGBboyG_9QXMso0Xw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3109530610</pqid></control><display><type>article</type><title>An integrated evanescent-field biosensor in silicon</title><source>Publicly Available Content Database</source><source>Coronavirus Research Database</source><creator>Al-Qadasi, Mohammed A ; Grist, Samantha M ; Mitchell, Matthew ; Newton, Karyn ; Kioussis, Stephen ; Chowdhury, Sheri J ; Randhawa, Avineet ; Liu, Yifei ; Tisapramotkul, Piramon ; Cheung, Karen C ; Chrostowski, Lukas ; Shekhar, Sudip</creator><creatorcontrib>Al-Qadasi, Mohammed A ; Grist, Samantha M ; Mitchell, Matthew ; Newton, Karyn ; Kioussis, Stephen ; Chowdhury, Sheri J ; Randhawa, Avineet ; Liu, Yifei ; Tisapramotkul, Piramon ; Cheung, Karen C ; Chrostowski, Lukas ; Shekhar, Sudip</creatorcontrib><description>Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated circuits are a promising technology to meet this need, as they can leverage (1) semiconductor manufacturing economies of scale, (2) exquisite optical sensitivity, and (3) the ability to integrate tens to hundreds of sensors on a millimeter-scale photonic chip. However, their application to decentralized testing has historically been limited by the expensive, bulky tunable lasers and alignment optics required for their readout. In this work, we introduce a segmented sensor architecture that addresses this important challenge by facilitating resonance-tracking readout using a fixed-wavelength laser. The architecture incorporates an in-resonator phase shifter modulated by CMOS drivers to periodically sweep and acquire the resonance peak shifts as well as a distinct high-sensitivity sensing region, maintaining high performance at a fraction of the cost and size. We show, for the first time, that fixed-wavelength sensor readout can offer similar performance to traditional tunable laser readout, demonstrating a system limit of detection of 6.1 x 10-5 RIU as well as immunoassay-based detection of the SARS-CoV-2 spike protein. We anticipate that this sensor architecture will open the door to a new data-rich class of portable, accurate, multiplexed diagnostics for decentralized testing.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Biomarkers ; Biosensors ; Economies of scale ; Immunoassay ; Integrated circuits ; Phase shifters ; Photonics ; Portability ; Resonance ; Resonators ; Sensitivity ; Sensors ; Silicon ; Tunable lasers</subject><ispartof>arXiv.org, 2024-10</ispartof><rights>2024. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/3109530610?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>780,784,25753,37012,38516,43895,44590</link.rule.ids></links><search><creatorcontrib>Al-Qadasi, Mohammed A</creatorcontrib><creatorcontrib>Grist, Samantha M</creatorcontrib><creatorcontrib>Mitchell, Matthew</creatorcontrib><creatorcontrib>Newton, Karyn</creatorcontrib><creatorcontrib>Kioussis, Stephen</creatorcontrib><creatorcontrib>Chowdhury, Sheri J</creatorcontrib><creatorcontrib>Randhawa, Avineet</creatorcontrib><creatorcontrib>Liu, Yifei</creatorcontrib><creatorcontrib>Tisapramotkul, Piramon</creatorcontrib><creatorcontrib>Cheung, Karen C</creatorcontrib><creatorcontrib>Chrostowski, Lukas</creatorcontrib><creatorcontrib>Shekhar, Sudip</creatorcontrib><title>An integrated evanescent-field biosensor in silicon</title><title>arXiv.org</title><description>Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated circuits are a promising technology to meet this need, as they can leverage (1) semiconductor manufacturing economies of scale, (2) exquisite optical sensitivity, and (3) the ability to integrate tens to hundreds of sensors on a millimeter-scale photonic chip. However, their application to decentralized testing has historically been limited by the expensive, bulky tunable lasers and alignment optics required for their readout. In this work, we introduce a segmented sensor architecture that addresses this important challenge by facilitating resonance-tracking readout using a fixed-wavelength laser. The architecture incorporates an in-resonator phase shifter modulated by CMOS drivers to periodically sweep and acquire the resonance peak shifts as well as a distinct high-sensitivity sensing region, maintaining high performance at a fraction of the cost and size. We show, for the first time, that fixed-wavelength sensor readout can offer similar performance to traditional tunable laser readout, demonstrating a system limit of detection of 6.1 x 10-5 RIU as well as immunoassay-based detection of the SARS-CoV-2 spike protein. We anticipate that this sensor architecture will open the door to a new data-rich class of portable, accurate, multiplexed diagnostics for decentralized testing.</description><subject>Biomarkers</subject><subject>Biosensors</subject><subject>Economies of scale</subject><subject>Immunoassay</subject><subject>Integrated circuits</subject><subject>Phase shifters</subject><subject>Photonics</subject><subject>Portability</subject><subject>Resonance</subject><subject>Resonators</subject><subject>Sensitivity</subject><subject>Sensors</subject><subject>Silicon</subject><subject>Tunable lasers</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>COVID</sourceid><sourceid>PIMPY</sourceid><recordid>eNqNykEKwjAQQNEgCBbtHQKuA0nGVF2KKB7AfYntVFLCRDOp57cLD-DqL_5biMoCGHXYWbsSNfOotbbN3joHlYATyUAFn9kX7CV-PCF3SEUNAWMvHyExEqc8K8khhi7RRiwHHxnrX9die73czzf1yuk9IZd2TFOmebVg9NGBboyG_9QXMso0Xw</recordid><startdate>20241021</startdate><enddate>20241021</enddate><creator>Al-Qadasi, Mohammed A</creator><creator>Grist, Samantha M</creator><creator>Mitchell, Matthew</creator><creator>Newton, Karyn</creator><creator>Kioussis, Stephen</creator><creator>Chowdhury, Sheri J</creator><creator>Randhawa, Avineet</creator><creator>Liu, Yifei</creator><creator>Tisapramotkul, Piramon</creator><creator>Cheung, Karen C</creator><creator>Chrostowski, Lukas</creator><creator>Shekhar, Sudip</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>COVID</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20241021</creationdate><title>An integrated evanescent-field biosensor in silicon</title><author>Al-Qadasi, Mohammed A ; Grist, Samantha M ; Mitchell, Matthew ; Newton, Karyn ; Kioussis, Stephen ; Chowdhury, Sheri J ; Randhawa, Avineet ; Liu, Yifei ; Tisapramotkul, Piramon ; Cheung, Karen C ; Chrostowski, Lukas ; Shekhar, Sudip</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_31095306103</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Biomarkers</topic><topic>Biosensors</topic><topic>Economies of scale</topic><topic>Immunoassay</topic><topic>Integrated circuits</topic><topic>Phase shifters</topic><topic>Photonics</topic><topic>Portability</topic><topic>Resonance</topic><topic>Resonators</topic><topic>Sensitivity</topic><topic>Sensors</topic><topic>Silicon</topic><topic>Tunable lasers</topic><toplevel>online_resources</toplevel><creatorcontrib>Al-Qadasi, Mohammed A</creatorcontrib><creatorcontrib>Grist, Samantha M</creatorcontrib><creatorcontrib>Mitchell, Matthew</creatorcontrib><creatorcontrib>Newton, Karyn</creatorcontrib><creatorcontrib>Kioussis, Stephen</creatorcontrib><creatorcontrib>Chowdhury, Sheri J</creatorcontrib><creatorcontrib>Randhawa, Avineet</creatorcontrib><creatorcontrib>Liu, Yifei</creatorcontrib><creatorcontrib>Tisapramotkul, Piramon</creatorcontrib><creatorcontrib>Cheung, Karen C</creatorcontrib><creatorcontrib>Chrostowski, Lukas</creatorcontrib><creatorcontrib>Shekhar, Sudip</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>Coronavirus Research Database</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al-Qadasi, Mohammed A</au><au>Grist, Samantha M</au><au>Mitchell, Matthew</au><au>Newton, Karyn</au><au>Kioussis, Stephen</au><au>Chowdhury, Sheri J</au><au>Randhawa, Avineet</au><au>Liu, Yifei</au><au>Tisapramotkul, Piramon</au><au>Cheung, Karen C</au><au>Chrostowski, Lukas</au><au>Shekhar, Sudip</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>An integrated evanescent-field biosensor in silicon</atitle><jtitle>arXiv.org</jtitle><date>2024-10-21</date><risdate>2024</risdate><eissn>2331-8422</eissn><abstract>Decentralized diagnostic testing that is accurate, portable, quantitative, and capable of making multiple simultaneous measurements of different biomarkers at the point-of-need remains an important unmet need in the post-pandemic world. Resonator-based biosensors using silicon photonic integrated circuits are a promising technology to meet this need, as they can leverage (1) semiconductor manufacturing economies of scale, (2) exquisite optical sensitivity, and (3) the ability to integrate tens to hundreds of sensors on a millimeter-scale photonic chip. However, their application to decentralized testing has historically been limited by the expensive, bulky tunable lasers and alignment optics required for their readout. In this work, we introduce a segmented sensor architecture that addresses this important challenge by facilitating resonance-tracking readout using a fixed-wavelength laser. The architecture incorporates an in-resonator phase shifter modulated by CMOS drivers to periodically sweep and acquire the resonance peak shifts as well as a distinct high-sensitivity sensing region, maintaining high performance at a fraction of the cost and size. We show, for the first time, that fixed-wavelength sensor readout can offer similar performance to traditional tunable laser readout, demonstrating a system limit of detection of 6.1 x 10-5 RIU as well as immunoassay-based detection of the SARS-CoV-2 spike protein. We anticipate that this sensor architecture will open the door to a new data-rich class of portable, accurate, multiplexed diagnostics for decentralized testing.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2024-10 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_3109530610 |
source | Publicly Available Content Database; Coronavirus Research Database |
subjects | Biomarkers Biosensors Economies of scale Immunoassay Integrated circuits Phase shifters Photonics Portability Resonance Resonators Sensitivity Sensors Silicon Tunable lasers |
title | An integrated evanescent-field biosensor in silicon |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T07%3A08%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=An%20integrated%20evanescent-field%20biosensor%20in%20silicon&rft.jtitle=arXiv.org&rft.au=Al-Qadasi,%20Mohammed%20A&rft.date=2024-10-21&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E3109530610%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_31095306103%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3109530610&rft_id=info:pmid/&rfr_iscdi=true |