Loading…
Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults
Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national...
Saved in:
Published in: | arXiv.org 2024-09 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | |
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Cherat, Naajein Nougain, Vaibhav Majstorović, Milovan Palensky, Peter Lekić, Aleksandra |
description | Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a \(\pm\)525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS). |
format | article |
fullrecord | <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_3110112772</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3110112772</sourcerecordid><originalsourceid>FETCH-proquest_journals_31101127723</originalsourceid><addsrcrecordid>eNqNyr0KwjAUQOEgCBbtO1xwDjSJta4ltDr4M9i9FJvUlDbRm1Tw7XXwAZzO8J0ZibgQjO42nC9I7H2fJAnfZjxNRUSuxUvZQCs0XadQtXB2lh6NVQ2CdDagG8BpuGjt7w4VnE4S9mhaD9oh5P49jiqguTUD5BLKZhqCX5G5bgav4l-XZF0WlTzQB7rnpHyoezeh_VItGEsY41nGxX_XB5YlPrY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3110112772</pqid></control><display><type>article</type><title>Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults</title><source>Publicly Available Content Database</source><creator>Cherat, Naajein ; Nougain, Vaibhav ; Majstorović, Milovan ; Palensky, Peter ; Lekić, Aleksandra</creator><creatorcontrib>Cherat, Naajein ; Nougain, Vaibhav ; Majstorović, Milovan ; Palensky, Peter ; Lekić, Aleksandra</creatorcontrib><description>Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a \(\pm\)525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS).</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Asymmetry ; Control systems ; Controllers ; Electric power systems ; Event triggered control ; Fault detection ; Faults ; Nonlinear control ; Offshore ; Power plants ; Proportional integral ; Sliding mode control ; Wind power</subject><ispartof>arXiv.org, 2024-09</ispartof><rights>2024. This work is published under http://arxiv.org/licenses/nonexclusive-distrib/1.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/3110112772?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>776,780,25731,36989,44566</link.rule.ids></links><search><creatorcontrib>Cherat, Naajein</creatorcontrib><creatorcontrib>Nougain, Vaibhav</creatorcontrib><creatorcontrib>Majstorović, Milovan</creatorcontrib><creatorcontrib>Palensky, Peter</creatorcontrib><creatorcontrib>Lekić, Aleksandra</creatorcontrib><title>Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults</title><title>arXiv.org</title><description>Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a \(\pm\)525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS).</description><subject>Asymmetry</subject><subject>Control systems</subject><subject>Controllers</subject><subject>Electric power systems</subject><subject>Event triggered control</subject><subject>Fault detection</subject><subject>Faults</subject><subject>Nonlinear control</subject><subject>Offshore</subject><subject>Power plants</subject><subject>Proportional integral</subject><subject>Sliding mode control</subject><subject>Wind power</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqNyr0KwjAUQOEgCBbtO1xwDjSJta4ltDr4M9i9FJvUlDbRm1Tw7XXwAZzO8J0ZibgQjO42nC9I7H2fJAnfZjxNRUSuxUvZQCs0XadQtXB2lh6NVQ2CdDagG8BpuGjt7w4VnE4S9mhaD9oh5P49jiqguTUD5BLKZhqCX5G5bgav4l-XZF0WlTzQB7rnpHyoezeh_VItGEsY41nGxX_XB5YlPrY</recordid><startdate>20240925</startdate><enddate>20240925</enddate><creator>Cherat, Naajein</creator><creator>Nougain, Vaibhav</creator><creator>Majstorović, Milovan</creator><creator>Palensky, Peter</creator><creator>Lekić, Aleksandra</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20240925</creationdate><title>Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults</title><author>Cherat, Naajein ; Nougain, Vaibhav ; Majstorović, Milovan ; Palensky, Peter ; Lekić, Aleksandra</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_31101127723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Asymmetry</topic><topic>Control systems</topic><topic>Controllers</topic><topic>Electric power systems</topic><topic>Event triggered control</topic><topic>Fault detection</topic><topic>Faults</topic><topic>Nonlinear control</topic><topic>Offshore</topic><topic>Power plants</topic><topic>Proportional integral</topic><topic>Sliding mode control</topic><topic>Wind power</topic><toplevel>online_resources</toplevel><creatorcontrib>Cherat, Naajein</creatorcontrib><creatorcontrib>Nougain, Vaibhav</creatorcontrib><creatorcontrib>Majstorović, Milovan</creatorcontrib><creatorcontrib>Palensky, Peter</creatorcontrib><creatorcontrib>Lekić, Aleksandra</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cherat, Naajein</au><au>Nougain, Vaibhav</au><au>Majstorović, Milovan</au><au>Palensky, Peter</au><au>Lekić, Aleksandra</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults</atitle><jtitle>arXiv.org</jtitle><date>2024-09-25</date><risdate>2024</risdate><eissn>2331-8422</eissn><abstract>Fault ride-through capability studies of MMC-HVDC connected wind power plants have focused primarily on the DC link and onshore AC grid faults. Offshore AC faults, mainly asymmetrical faults have not gained much attention in the literature despite being included in the future development at national levels in the ENTSO-E HVDC code. The proposed work gives an event-triggered control to stabilize the system once the offshore AC fault has occurred, identified, and isolated. Different types of control actions such as proportional-integral (PI) controller and super-twisted sliding mode control (STSMC) are used to smoothly transition the post-fault system to a new steady state operating point by suppressing the negative sequence control. Initially, the effect of a negative sequence current control scheme on the transient behavior of the power system with a PI controller is discussed in this paper. Further, a non-linear control strategy (STSMC) is proposed which gives quicker convergence of the system post-fault in comparison to PI control action. These post-fault control operations are only triggered in the presence of a fault in the system, i.e., they are event-triggered. The validity of the proposed strategy is demonstrated by simulation on a \(\pm\)525 kV, three-terminal meshed MMC-HVDC system model in Real Time Digital Simulator (RTDS).</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2024-09 |
issn | 2331-8422 |
language | eng |
recordid | cdi_proquest_journals_3110112772 |
source | Publicly Available Content Database |
subjects | Asymmetry Control systems Controllers Electric power systems Event triggered control Fault detection Faults Nonlinear control Offshore Power plants Proportional integral Sliding mode control Wind power |
title | Event-Triggered Non-Linear Control of Offshore MMC Grids for Asymmetrical AC Faults |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T16%3A08%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=Event-Triggered%20Non-Linear%20Control%20of%20Offshore%20MMC%20Grids%20for%20Asymmetrical%20AC%20Faults&rft.jtitle=arXiv.org&rft.au=Cherat,%20Naajein&rft.date=2024-09-25&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E3110112772%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_31101127723%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3110112772&rft_id=info:pmid/&rfr_iscdi=true |