Loading…

An iteration-free approach to excitation harmonization

Sinusoidal excitation is particularly popular for testing structures in the nonlinear regime. Due to the nonlinear behavior and the inevitable feedback of the structure on the exciter, higher harmonics in the applied excitation are generated. This is undesired, because the acquired response may devi...

Full description

Saved in:
Bibliographic Details
Published in:arXiv.org 2024-10
Main Authors: Hippold, Patrick, Kleyman, Gleb, Woiwode, Lukas, Tong, Wei, Müller, Florian, Schwingshackl, Christoph, Scheel, Maren, Tatzko, Sebastian, Krack, Malte
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Hippold, Patrick
Kleyman, Gleb
Woiwode, Lukas
Tong, Wei
Müller, Florian
Schwingshackl, Christoph
Scheel, Maren
Tatzko, Sebastian
Krack, Malte
description Sinusoidal excitation is particularly popular for testing structures in the nonlinear regime. Due to the nonlinear behavior and the inevitable feedback of the structure on the exciter, higher harmonics in the applied excitation are generated. This is undesired, because the acquired response may deviate substantially from that of the structure under purely sinusoidal excitation, in particular if one of the higher harmonics engages into resonance. We present a new approach to suppress those higher excitation harmonics and thus the unwanted exciter-structure interaction: Higher harmonics are added to the voltage input to the shaker whose Fourier coefficients are adjusted via feedback control until the excitation is purely sinusoidal. The stability of this method is analyzed for a simplified model; the resulting closed-form expressions are useful, among others, to select an appropriate exciter configuration, including the drive point. A practical procedure for the control design is suggested. The proposed method is validated in virtual and real experiments of internally resonant structures, in the two common configurations of force excitation via a stinger and base excitation. Excellent performance is achieved already when using the same control gains for all harmonics, throughout the tested range of amplitudes and frequencies, even in the strongly nonlinear regime. Compared to the iterative state of the art, it is found that the proposed method is simpler to implement, enables faster testing and it is easy to achieve a lower harmonic distortion.
format article
fullrecord <record><control><sourceid>proquest</sourceid><recordid>TN_cdi_proquest_journals_3120207847</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3120207847</sourcerecordid><originalsourceid>FETCH-proquest_journals_31202078473</originalsourceid><addsrcrecordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQwc8xTyCxJLUosyczP000rSk1VSCwoKMpPTM5QKMlXSK1IziwByylkJBbl5udlVoF5PAysaYk5xam8UJqbQdnNNcTZQxeotbA0tbgkPiu_tCgPKBVvbGhkYGRgbmFibkycKgABkzXY</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3120207847</pqid></control><display><type>article</type><title>An iteration-free approach to excitation harmonization</title><source>Publicly Available Content (ProQuest)</source><creator>Hippold, Patrick ; Kleyman, Gleb ; Woiwode, Lukas ; Tong, Wei ; Müller, Florian ; Schwingshackl, Christoph ; Scheel, Maren ; Tatzko, Sebastian ; Krack, Malte</creator><creatorcontrib>Hippold, Patrick ; Kleyman, Gleb ; Woiwode, Lukas ; Tong, Wei ; Müller, Florian ; Schwingshackl, Christoph ; Scheel, Maren ; Tatzko, Sebastian ; Krack, Malte</creatorcontrib><description>Sinusoidal excitation is particularly popular for testing structures in the nonlinear regime. Due to the nonlinear behavior and the inevitable feedback of the structure on the exciter, higher harmonics in the applied excitation are generated. This is undesired, because the acquired response may deviate substantially from that of the structure under purely sinusoidal excitation, in particular if one of the higher harmonics engages into resonance. We present a new approach to suppress those higher excitation harmonics and thus the unwanted exciter-structure interaction: Higher harmonics are added to the voltage input to the shaker whose Fourier coefficients are adjusted via feedback control until the excitation is purely sinusoidal. The stability of this method is analyzed for a simplified model; the resulting closed-form expressions are useful, among others, to select an appropriate exciter configuration, including the drive point. A practical procedure for the control design is suggested. The proposed method is validated in virtual and real experiments of internally resonant structures, in the two common configurations of force excitation via a stinger and base excitation. Excellent performance is achieved already when using the same control gains for all harmonics, throughout the tested range of amplitudes and frequencies, even in the strongly nonlinear regime. Compared to the iterative state of the art, it is found that the proposed method is simpler to implement, enables faster testing and it is easy to achieve a lower harmonic distortion.</description><identifier>EISSN: 2331-8422</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Configuration management ; Control stability ; Excitation ; Feedback control ; Harmonic distortion ; Higher harmonics ; Nonlinear control ; Sine waves</subject><ispartof>arXiv.org, 2024-10</ispartof><rights>2024. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.proquest.com/docview/3120207847?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>776,780,25733,36991,44569</link.rule.ids></links><search><creatorcontrib>Hippold, Patrick</creatorcontrib><creatorcontrib>Kleyman, Gleb</creatorcontrib><creatorcontrib>Woiwode, Lukas</creatorcontrib><creatorcontrib>Tong, Wei</creatorcontrib><creatorcontrib>Müller, Florian</creatorcontrib><creatorcontrib>Schwingshackl, Christoph</creatorcontrib><creatorcontrib>Scheel, Maren</creatorcontrib><creatorcontrib>Tatzko, Sebastian</creatorcontrib><creatorcontrib>Krack, Malte</creatorcontrib><title>An iteration-free approach to excitation harmonization</title><title>arXiv.org</title><description>Sinusoidal excitation is particularly popular for testing structures in the nonlinear regime. Due to the nonlinear behavior and the inevitable feedback of the structure on the exciter, higher harmonics in the applied excitation are generated. This is undesired, because the acquired response may deviate substantially from that of the structure under purely sinusoidal excitation, in particular if one of the higher harmonics engages into resonance. We present a new approach to suppress those higher excitation harmonics and thus the unwanted exciter-structure interaction: Higher harmonics are added to the voltage input to the shaker whose Fourier coefficients are adjusted via feedback control until the excitation is purely sinusoidal. The stability of this method is analyzed for a simplified model; the resulting closed-form expressions are useful, among others, to select an appropriate exciter configuration, including the drive point. A practical procedure for the control design is suggested. The proposed method is validated in virtual and real experiments of internally resonant structures, in the two common configurations of force excitation via a stinger and base excitation. Excellent performance is achieved already when using the same control gains for all harmonics, throughout the tested range of amplitudes and frequencies, even in the strongly nonlinear regime. Compared to the iterative state of the art, it is found that the proposed method is simpler to implement, enables faster testing and it is easy to achieve a lower harmonic distortion.</description><subject>Configuration management</subject><subject>Control stability</subject><subject>Excitation</subject><subject>Feedback control</subject><subject>Harmonic distortion</subject><subject>Higher harmonics</subject><subject>Nonlinear control</subject><subject>Sine waves</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpjYuA0MjY21LUwMTLiYOAtLs4yMDAwMjM3MjU15mQwc8xTyCxJLUosyczP000rSk1VSCwoKMpPTM5QKMlXSK1IziwByylkJBbl5udlVoF5PAysaYk5xam8UJqbQdnNNcTZQxeotbA0tbgkPiu_tCgPKBVvbGhkYGRgbmFibkycKgABkzXY</recordid><startdate>20241023</startdate><enddate>20241023</enddate><creator>Hippold, Patrick</creator><creator>Kleyman, Gleb</creator><creator>Woiwode, Lukas</creator><creator>Tong, Wei</creator><creator>Müller, Florian</creator><creator>Schwingshackl, Christoph</creator><creator>Scheel, Maren</creator><creator>Tatzko, Sebastian</creator><creator>Krack, Malte</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope></search><sort><creationdate>20241023</creationdate><title>An iteration-free approach to excitation harmonization</title><author>Hippold, Patrick ; Kleyman, Gleb ; Woiwode, Lukas ; Tong, Wei ; Müller, Florian ; Schwingshackl, Christoph ; Scheel, Maren ; Tatzko, Sebastian ; Krack, Malte</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-proquest_journals_31202078473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Configuration management</topic><topic>Control stability</topic><topic>Excitation</topic><topic>Feedback control</topic><topic>Harmonic distortion</topic><topic>Higher harmonics</topic><topic>Nonlinear control</topic><topic>Sine waves</topic><toplevel>online_resources</toplevel><creatorcontrib>Hippold, Patrick</creatorcontrib><creatorcontrib>Kleyman, Gleb</creatorcontrib><creatorcontrib>Woiwode, Lukas</creatorcontrib><creatorcontrib>Tong, Wei</creatorcontrib><creatorcontrib>Müller, Florian</creatorcontrib><creatorcontrib>Schwingshackl, Christoph</creatorcontrib><creatorcontrib>Scheel, Maren</creatorcontrib><creatorcontrib>Tatzko, Sebastian</creatorcontrib><creatorcontrib>Krack, Malte</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>ProQuest Engineering Database</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering collection</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hippold, Patrick</au><au>Kleyman, Gleb</au><au>Woiwode, Lukas</au><au>Tong, Wei</au><au>Müller, Florian</au><au>Schwingshackl, Christoph</au><au>Scheel, Maren</au><au>Tatzko, Sebastian</au><au>Krack, Malte</au><format>book</format><genre>document</genre><ristype>GEN</ristype><atitle>An iteration-free approach to excitation harmonization</atitle><jtitle>arXiv.org</jtitle><date>2024-10-23</date><risdate>2024</risdate><eissn>2331-8422</eissn><abstract>Sinusoidal excitation is particularly popular for testing structures in the nonlinear regime. Due to the nonlinear behavior and the inevitable feedback of the structure on the exciter, higher harmonics in the applied excitation are generated. This is undesired, because the acquired response may deviate substantially from that of the structure under purely sinusoidal excitation, in particular if one of the higher harmonics engages into resonance. We present a new approach to suppress those higher excitation harmonics and thus the unwanted exciter-structure interaction: Higher harmonics are added to the voltage input to the shaker whose Fourier coefficients are adjusted via feedback control until the excitation is purely sinusoidal. The stability of this method is analyzed for a simplified model; the resulting closed-form expressions are useful, among others, to select an appropriate exciter configuration, including the drive point. A practical procedure for the control design is suggested. The proposed method is validated in virtual and real experiments of internally resonant structures, in the two common configurations of force excitation via a stinger and base excitation. Excellent performance is achieved already when using the same control gains for all harmonics, throughout the tested range of amplitudes and frequencies, even in the strongly nonlinear regime. Compared to the iterative state of the art, it is found that the proposed method is simpler to implement, enables faster testing and it is easy to achieve a lower harmonic distortion.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2024-10
issn 2331-8422
language eng
recordid cdi_proquest_journals_3120207847
source Publicly Available Content (ProQuest)
subjects Configuration management
Control stability
Excitation
Feedback control
Harmonic distortion
Higher harmonics
Nonlinear control
Sine waves
title An iteration-free approach to excitation harmonization
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T15%3A54%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=document&rft.atitle=An%20iteration-free%20approach%20to%20excitation%20harmonization&rft.jtitle=arXiv.org&rft.au=Hippold,%20Patrick&rft.date=2024-10-23&rft.eissn=2331-8422&rft_id=info:doi/&rft_dat=%3Cproquest%3E3120207847%3C/proquest%3E%3Cgrp_id%3Ecdi_FETCH-proquest_journals_31202078473%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3120207847&rft_id=info:pmid/&rfr_iscdi=true