Loading…
Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study
ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthe...
Saved in:
Published in: | Journal of pharmacy & bioallied science 2024-12, Vol.16 (Suppl 4), p.S3427-S3429 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63 |
container_end_page | S3429 |
container_issue | Suppl 4 |
container_start_page | S3427 |
container_title | Journal of pharmacy & bioallied science |
container_volume | 16 |
creator | Bera, Trinanjali Kukreja, Bhavna Jha Sharma, Chetan Gupta, Vivek V Patel, Priya Singhal, Parul Jadhav, Manish S Pattnaik, Naina |
description | ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone |
doi_str_mv | 10.4103/jpbs.jpbs_899_24 |
format | article |
fullrecord | <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_proquest_journals_3149313524</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A821410888</galeid><doaj_id>oai_doaj_org_article_deae8de843674ee892cb917ed6729d82</doaj_id><sourcerecordid>A821410888</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63</originalsourceid><addsrcrecordid>eNptUU2LFDEQbUTBZd27x4DnHvPVncTbOOg6sKLoeg7VSWXJ2NMZ0-mF-fdmZsQPMAVJqHr1qFevaV4yupKMite7wzCvTpfVxlgunzRX1KiuVZL2T8__vpVamefNzTzvaD3CcMPEVfP9C45Q4iOSTZpKjsNSYppICuQ-w4BuGSETmHwt5xIdjORtmpCURD7nuId8JNv9YYSpkK8FhjjGcnxD1hPZTuQxlpzIx-RxrMXFH180zwKMM978eq-bb-_f3W8-tHefbreb9V3ruJSyNUEw7qTnTHZOS0XN0HntKA5CaTcERh3jfQDqO9VLFxRo4F51gfZCKuzFdbO98PoEO3u4zGkTRHtOpPxg4SRmROsRUHvUUvRKImrD3WCYQt8rbrzmlevVheuQ048F52J3aclTHd8KJo1gouPyD-oBKmmcQioZ3D7Ozq511cGo1rqiVv9B1fC4j66uNcSa_6eBXhpcTvOcMfwWw6g9GW_Pnv9lvPgJe86hdg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3149313524</pqid></control><display><type>article</type><title>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</title><source>PubMed Central</source><creator>Bera, Trinanjali ; Kukreja, Bhavna Jha ; Sharma, Chetan ; Gupta, Vivek V ; Patel, Priya ; Singhal, Parul ; Jadhav, Manish S ; Pattnaik, Naina</creator><creatorcontrib>Bera, Trinanjali ; Kukreja, Bhavna Jha ; Sharma, Chetan ; Gupta, Vivek V ; Patel, Priya ; Singhal, Parul ; Jadhav, Manish S ; Pattnaik, Naina</creatorcontrib><description>ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone</description><identifier>ISSN: 0976-4879</identifier><identifier>EISSN: 0975-7406</identifier><identifier>DOI: 10.4103/jpbs.jpbs_899_24</identifier><language>eng</language><publisher>Mumbai: Medknow Publications and Media Pvt. Ltd</publisher><subject>Analysis ; Bone density ; Bone implants ; Bones ; Cancellous bone ; Cortical bone ; Density ; dental implants ; Dental prosthetics ; Implant dentures ; insertion torque ; Long bone ; Osseointegration ; primary implant stability ; resonance frequency analysis ; trabecular bone ; Transplants & implants</subject><ispartof>Journal of pharmacy & bioallied science, 2024-12, Vol.16 (Suppl 4), p.S3427-S3429</ispartof><rights>COPYRIGHT 2024 Medknow Publications and Media Pvt. Ltd.</rights><rights>2024. This article is published under (http://creativecommons.org/licenses/by-nc-sa/3.0/) (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Bera, Trinanjali</creatorcontrib><creatorcontrib>Kukreja, Bhavna Jha</creatorcontrib><creatorcontrib>Sharma, Chetan</creatorcontrib><creatorcontrib>Gupta, Vivek V</creatorcontrib><creatorcontrib>Patel, Priya</creatorcontrib><creatorcontrib>Singhal, Parul</creatorcontrib><creatorcontrib>Jadhav, Manish S</creatorcontrib><creatorcontrib>Pattnaik, Naina</creatorcontrib><title>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</title><title>Journal of pharmacy & bioallied science</title><description>ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone</description><subject>Analysis</subject><subject>Bone density</subject><subject>Bone implants</subject><subject>Bones</subject><subject>Cancellous bone</subject><subject>Cortical bone</subject><subject>Density</subject><subject>dental implants</subject><subject>Dental prosthetics</subject><subject>Implant dentures</subject><subject>insertion torque</subject><subject>Long bone</subject><subject>Osseointegration</subject><subject>primary implant stability</subject><subject>resonance frequency analysis</subject><subject>trabecular bone</subject><subject>Transplants & implants</subject><issn>0976-4879</issn><issn>0975-7406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNptUU2LFDEQbUTBZd27x4DnHvPVncTbOOg6sKLoeg7VSWXJ2NMZ0-mF-fdmZsQPMAVJqHr1qFevaV4yupKMite7wzCvTpfVxlgunzRX1KiuVZL2T8__vpVamefNzTzvaD3CcMPEVfP9C45Q4iOSTZpKjsNSYppICuQ-w4BuGSETmHwt5xIdjORtmpCURD7nuId8JNv9YYSpkK8FhjjGcnxD1hPZTuQxlpzIx-RxrMXFH180zwKMM978eq-bb-_f3W8-tHefbreb9V3ruJSyNUEw7qTnTHZOS0XN0HntKA5CaTcERh3jfQDqO9VLFxRo4F51gfZCKuzFdbO98PoEO3u4zGkTRHtOpPxg4SRmROsRUHvUUvRKImrD3WCYQt8rbrzmlevVheuQ048F52J3aclTHd8KJo1gouPyD-oBKmmcQioZ3D7Ozq511cGo1rqiVv9B1fC4j66uNcSa_6eBXhpcTvOcMfwWw6g9GW_Pnv9lvPgJe86hdg</recordid><startdate>20241201</startdate><enddate>20241201</enddate><creator>Bera, Trinanjali</creator><creator>Kukreja, Bhavna Jha</creator><creator>Sharma, Chetan</creator><creator>Gupta, Vivek V</creator><creator>Patel, Priya</creator><creator>Singhal, Parul</creator><creator>Jadhav, Manish S</creator><creator>Pattnaik, Naina</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt. Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>DOA</scope></search><sort><creationdate>20241201</creationdate><title>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</title><author>Bera, Trinanjali ; Kukreja, Bhavna Jha ; Sharma, Chetan ; Gupta, Vivek V ; Patel, Priya ; Singhal, Parul ; Jadhav, Manish S ; Pattnaik, Naina</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Analysis</topic><topic>Bone density</topic><topic>Bone implants</topic><topic>Bones</topic><topic>Cancellous bone</topic><topic>Cortical bone</topic><topic>Density</topic><topic>dental implants</topic><topic>Dental prosthetics</topic><topic>Implant dentures</topic><topic>insertion torque</topic><topic>Long bone</topic><topic>Osseointegration</topic><topic>primary implant stability</topic><topic>resonance frequency analysis</topic><topic>trabecular bone</topic><topic>Transplants & implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bera, Trinanjali</creatorcontrib><creatorcontrib>Kukreja, Bhavna Jha</creatorcontrib><creatorcontrib>Sharma, Chetan</creatorcontrib><creatorcontrib>Gupta, Vivek V</creatorcontrib><creatorcontrib>Patel, Priya</creatorcontrib><creatorcontrib>Singhal, Parul</creatorcontrib><creatorcontrib>Jadhav, Manish S</creatorcontrib><creatorcontrib>Pattnaik, Naina</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Nursing & Allied Health Premium</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Journal of pharmacy & bioallied science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bera, Trinanjali</au><au>Kukreja, Bhavna Jha</au><au>Sharma, Chetan</au><au>Gupta, Vivek V</au><au>Patel, Priya</au><au>Singhal, Parul</au><au>Jadhav, Manish S</au><au>Pattnaik, Naina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</atitle><jtitle>Journal of pharmacy & bioallied science</jtitle><date>2024-12-01</date><risdate>2024</risdate><volume>16</volume><issue>Suppl 4</issue><spage>S3427</spage><epage>S3429</epage><pages>S3427-S3429</pages><issn>0976-4879</issn><eissn>0975-7406</eissn><abstract>ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone</abstract><cop>Mumbai</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><doi>10.4103/jpbs.jpbs_899_24</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0976-4879 |
ispartof | Journal of pharmacy & bioallied science, 2024-12, Vol.16 (Suppl 4), p.S3427-S3429 |
issn | 0976-4879 0975-7406 |
language | eng |
recordid | cdi_proquest_journals_3149313524 |
source | PubMed Central |
subjects | Analysis Bone density Bone implants Bones Cancellous bone Cortical bone Density dental implants Dental prosthetics Implant dentures insertion torque Long bone Osseointegration primary implant stability resonance frequency analysis trabecular bone Transplants & implants |
title | Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T08%3A17%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relative%20Contribution%20of%20Trabecular%20and%20Cortical%20Bone%20to%20Primary%20Implant%20Stability:%20An%20In%20vitro%20Model%20Study&rft.jtitle=Journal%20of%20pharmacy%20&%20bioallied%20science&rft.au=Bera,%20Trinanjali&rft.date=2024-12-01&rft.volume=16&rft.issue=Suppl%204&rft.spage=S3427&rft.epage=S3429&rft.pages=S3427-S3429&rft.issn=0976-4879&rft.eissn=0975-7406&rft_id=info:doi/10.4103/jpbs.jpbs_899_24&rft_dat=%3Cgale_doaj_%3EA821410888%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3149313524&rft_id=info:pmid/&rft_galeid=A821410888&rfr_iscdi=true |