Loading…

Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study

ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthe...

Full description

Saved in:
Bibliographic Details
Published in:Journal of pharmacy & bioallied science 2024-12, Vol.16 (Suppl 4), p.S3427-S3429
Main Authors: Bera, Trinanjali, Kukreja, Bhavna Jha, Sharma, Chetan, Gupta, Vivek V, Patel, Priya, Singhal, Parul, Jadhav, Manish S, Pattnaik, Naina
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63
container_end_page S3429
container_issue Suppl 4
container_start_page S3427
container_title Journal of pharmacy & bioallied science
container_volume 16
creator Bera, Trinanjali
Kukreja, Bhavna Jha
Sharma, Chetan
Gupta, Vivek V
Patel, Priya
Singhal, Parul
Jadhav, Manish S
Pattnaik, Naina
description ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone
doi_str_mv 10.4103/jpbs.jpbs_899_24
format article
fullrecord <record><control><sourceid>gale_doaj_</sourceid><recordid>TN_cdi_proquest_journals_3149313524</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A821410888</galeid><doaj_id>oai_doaj_org_article_deae8de843674ee892cb917ed6729d82</doaj_id><sourcerecordid>A821410888</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63</originalsourceid><addsrcrecordid>eNptUU2LFDEQbUTBZd27x4DnHvPVncTbOOg6sKLoeg7VSWXJ2NMZ0-mF-fdmZsQPMAVJqHr1qFevaV4yupKMite7wzCvTpfVxlgunzRX1KiuVZL2T8__vpVamefNzTzvaD3CcMPEVfP9C45Q4iOSTZpKjsNSYppICuQ-w4BuGSETmHwt5xIdjORtmpCURD7nuId8JNv9YYSpkK8FhjjGcnxD1hPZTuQxlpzIx-RxrMXFH180zwKMM978eq-bb-_f3W8-tHefbreb9V3ruJSyNUEw7qTnTHZOS0XN0HntKA5CaTcERh3jfQDqO9VLFxRo4F51gfZCKuzFdbO98PoEO3u4zGkTRHtOpPxg4SRmROsRUHvUUvRKImrD3WCYQt8rbrzmlevVheuQ048F52J3aclTHd8KJo1gouPyD-oBKmmcQioZ3D7Ozq511cGo1rqiVv9B1fC4j66uNcSa_6eBXhpcTvOcMfwWw6g9GW_Pnv9lvPgJe86hdg</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3149313524</pqid></control><display><type>article</type><title>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</title><source>PubMed Central</source><creator>Bera, Trinanjali ; Kukreja, Bhavna Jha ; Sharma, Chetan ; Gupta, Vivek V ; Patel, Priya ; Singhal, Parul ; Jadhav, Manish S ; Pattnaik, Naina</creator><creatorcontrib>Bera, Trinanjali ; Kukreja, Bhavna Jha ; Sharma, Chetan ; Gupta, Vivek V ; Patel, Priya ; Singhal, Parul ; Jadhav, Manish S ; Pattnaik, Naina</creatorcontrib><description>ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone</description><identifier>ISSN: 0976-4879</identifier><identifier>EISSN: 0975-7406</identifier><identifier>DOI: 10.4103/jpbs.jpbs_899_24</identifier><language>eng</language><publisher>Mumbai: Medknow Publications and Media Pvt. Ltd</publisher><subject>Analysis ; Bone density ; Bone implants ; Bones ; Cancellous bone ; Cortical bone ; Density ; dental implants ; Dental prosthetics ; Implant dentures ; insertion torque ; Long bone ; Osseointegration ; primary implant stability ; resonance frequency analysis ; trabecular bone ; Transplants &amp; implants</subject><ispartof>Journal of pharmacy &amp; bioallied science, 2024-12, Vol.16 (Suppl 4), p.S3427-S3429</ispartof><rights>COPYRIGHT 2024 Medknow Publications and Media Pvt. Ltd.</rights><rights>2024. This article is published under (http://creativecommons.org/licenses/by-nc-sa/3.0/) (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Bera, Trinanjali</creatorcontrib><creatorcontrib>Kukreja, Bhavna Jha</creatorcontrib><creatorcontrib>Sharma, Chetan</creatorcontrib><creatorcontrib>Gupta, Vivek V</creatorcontrib><creatorcontrib>Patel, Priya</creatorcontrib><creatorcontrib>Singhal, Parul</creatorcontrib><creatorcontrib>Jadhav, Manish S</creatorcontrib><creatorcontrib>Pattnaik, Naina</creatorcontrib><title>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</title><title>Journal of pharmacy &amp; bioallied science</title><description>ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone</description><subject>Analysis</subject><subject>Bone density</subject><subject>Bone implants</subject><subject>Bones</subject><subject>Cancellous bone</subject><subject>Cortical bone</subject><subject>Density</subject><subject>dental implants</subject><subject>Dental prosthetics</subject><subject>Implant dentures</subject><subject>insertion torque</subject><subject>Long bone</subject><subject>Osseointegration</subject><subject>primary implant stability</subject><subject>resonance frequency analysis</subject><subject>trabecular bone</subject><subject>Transplants &amp; implants</subject><issn>0976-4879</issn><issn>0975-7406</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>DOA</sourceid><recordid>eNptUU2LFDEQbUTBZd27x4DnHvPVncTbOOg6sKLoeg7VSWXJ2NMZ0-mF-fdmZsQPMAVJqHr1qFevaV4yupKMite7wzCvTpfVxlgunzRX1KiuVZL2T8__vpVamefNzTzvaD3CcMPEVfP9C45Q4iOSTZpKjsNSYppICuQ-w4BuGSETmHwt5xIdjORtmpCURD7nuId8JNv9YYSpkK8FhjjGcnxD1hPZTuQxlpzIx-RxrMXFH180zwKMM978eq-bb-_f3W8-tHefbreb9V3ruJSyNUEw7qTnTHZOS0XN0HntKA5CaTcERh3jfQDqO9VLFxRo4F51gfZCKuzFdbO98PoEO3u4zGkTRHtOpPxg4SRmROsRUHvUUvRKImrD3WCYQt8rbrzmlevVheuQ048F52J3aclTHd8KJo1gouPyD-oBKmmcQioZ3D7Ozq511cGo1rqiVv9B1fC4j66uNcSa_6eBXhpcTvOcMfwWw6g9GW_Pnv9lvPgJe86hdg</recordid><startdate>20241201</startdate><enddate>20241201</enddate><creator>Bera, Trinanjali</creator><creator>Kukreja, Bhavna Jha</creator><creator>Sharma, Chetan</creator><creator>Gupta, Vivek V</creator><creator>Patel, Priya</creator><creator>Singhal, Parul</creator><creator>Jadhav, Manish S</creator><creator>Pattnaik, Naina</creator><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications &amp; Media Pvt. Ltd</general><general>Wolters Kluwer Medknow Publications</general><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>NAPCQ</scope><scope>DOA</scope></search><sort><creationdate>20241201</creationdate><title>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</title><author>Bera, Trinanjali ; Kukreja, Bhavna Jha ; Sharma, Chetan ; Gupta, Vivek V ; Patel, Priya ; Singhal, Parul ; Jadhav, Manish S ; Pattnaik, Naina</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Analysis</topic><topic>Bone density</topic><topic>Bone implants</topic><topic>Bones</topic><topic>Cancellous bone</topic><topic>Cortical bone</topic><topic>Density</topic><topic>dental implants</topic><topic>Dental prosthetics</topic><topic>Implant dentures</topic><topic>insertion torque</topic><topic>Long bone</topic><topic>Osseointegration</topic><topic>primary implant stability</topic><topic>resonance frequency analysis</topic><topic>trabecular bone</topic><topic>Transplants &amp; implants</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bera, Trinanjali</creatorcontrib><creatorcontrib>Kukreja, Bhavna Jha</creatorcontrib><creatorcontrib>Sharma, Chetan</creatorcontrib><creatorcontrib>Gupta, Vivek V</creatorcontrib><creatorcontrib>Patel, Priya</creatorcontrib><creatorcontrib>Singhal, Parul</creatorcontrib><creatorcontrib>Jadhav, Manish S</creatorcontrib><creatorcontrib>Pattnaik, Naina</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Journal of pharmacy &amp; bioallied science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bera, Trinanjali</au><au>Kukreja, Bhavna Jha</au><au>Sharma, Chetan</au><au>Gupta, Vivek V</au><au>Patel, Priya</au><au>Singhal, Parul</au><au>Jadhav, Manish S</au><au>Pattnaik, Naina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study</atitle><jtitle>Journal of pharmacy &amp; bioallied science</jtitle><date>2024-12-01</date><risdate>2024</risdate><volume>16</volume><issue>Suppl 4</issue><spage>S3427</spage><epage>S3429</epage><pages>S3427-S3429</pages><issn>0976-4879</issn><eissn>0975-7406</eissn><abstract>ABSTRACT Background: Primary implant stability is a crucial factor for the successful osseointegration and long-term success of dental implants. The contribution of trabecular and cortical bone to primary implant stability is not well understood. Materials and Methods: An in vitro model using synthetic bone blocks mimicking trabecular and cortical bone was used to simulate implant placement. The study involved 40 implants, divided into four groups based on bone type and density: Group A (low-density trabecular bone), Group B (high-density trabecular bone), Group C (low-density cortical bone), and Group D (high-density cortical bone). Primary stability was assessed using insertion torque values and resonance frequency analysis (RFA). Insertion torque was measured using a digital torque meter, and RFA was measured using an Osstell ISQ device. Results: Group D (high-density cortical bone) exhibited the highest insertion torque values (mean: 45 Ncm) and Implant Stability Quotient (ISQ) values (mean: 75), indicating superior primary stability. Group C (low-density cortical bone) showed moderate stability, with mean insertion torque values of 30 Ncm and ISQ values of 60. Group B (high-density trabecular bone) had lower stability, with mean insertion torque values of 25 Ncm and ISQ values of 55. Group A (low-density trabecular bone) demonstrated the least stability, with mean insertion torque values of 15 Ncm and ISQ values of 45. Conclusion: The study concludes that cortical bone, especially high-density cortical bone, significantly contributes to primary implant stability compared to trabecular bone. The findings suggest that bone quality should be a major consideration during implant placement to ensure optimal primary stability and long-term success. Keywords: Cortical bone, dental implants, insertion torque, osseointegration, primary implant stability, resonance frequency analysis, trabecular bone</abstract><cop>Mumbai</cop><pub>Medknow Publications and Media Pvt. Ltd</pub><doi>10.4103/jpbs.jpbs_899_24</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0976-4879
ispartof Journal of pharmacy & bioallied science, 2024-12, Vol.16 (Suppl 4), p.S3427-S3429
issn 0976-4879
0975-7406
language eng
recordid cdi_proquest_journals_3149313524
source PubMed Central
subjects Analysis
Bone density
Bone implants
Bones
Cancellous bone
Cortical bone
Density
dental implants
Dental prosthetics
Implant dentures
insertion torque
Long bone
Osseointegration
primary implant stability
resonance frequency analysis
trabecular bone
Transplants & implants
title Relative Contribution of Trabecular and Cortical Bone to Primary Implant Stability: An In vitro Model Study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T08%3A17%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Relative%20Contribution%20of%20Trabecular%20and%20Cortical%20Bone%20to%20Primary%20Implant%20Stability:%20An%20In%20vitro%20Model%20Study&rft.jtitle=Journal%20of%20pharmacy%20&%20bioallied%20science&rft.au=Bera,%20Trinanjali&rft.date=2024-12-01&rft.volume=16&rft.issue=Suppl%204&rft.spage=S3427&rft.epage=S3429&rft.pages=S3427-S3429&rft.issn=0976-4879&rft.eissn=0975-7406&rft_id=info:doi/10.4103/jpbs.jpbs_899_24&rft_dat=%3Cgale_doaj_%3EA821410888%3C/gale_doaj_%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2444-9f312c4d2145c84709b5d8c0eb378cbf10c126fa0d5764cf7a8a2d75f06347e63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=3149313524&rft_id=info:pmid/&rft_galeid=A821410888&rfr_iscdi=true