Loading…
An important role for VCAM-1, but not for ICAM-1 in restenosis following coronary stent implantation/Koroner stent implantasyonu sonrasi restenozda ICAM-1'e göre VCAM-1'in önemli rölü
In this study, we evaluated the possibility that, levels of circulating adhesion molecules following direct stent implantation may be a marker of restenosis. This prospective, observational study investigated levels of circulating intercellular (ICAM-1), and vascular cell (VCAM-1) adhesion molecules...
Saved in:
Published in: | Anatolian journal of cardiology 2010-10, Vol.10 (5), p.405 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this study, we evaluated the possibility that, levels of circulating adhesion molecules following direct stent implantation may be a marker of restenosis. This prospective, observational study investigated levels of circulating intercellular (ICAM-1), and vascular cell (VCAM-1) adhesion molecules in 15 patients with stable angina pectoris before and after coronary stent implantation for single vessel-single lesion disease in proximal left anterior descending artery. All patients received bare-metal stents. Patients underwent repeat coronary angiography for detection of restenosis at 6 month. Continuous data between patients with and without restenosis were compared using Mann-Whitney U test. Repeated measurements were compared using Wilcoxon T test. Categorical data were compared using Chi-square statistics. Baseline ICAM-1 and VCAM-1 concentrations before percutaneous coronary intervention (PCI) were 4.89±2.28 and 46.35±22.96 ng/ml respectively. Levels of ICAM and VCAM increased nonsignificantly 24 hours after PCI (5.01±2.35 ng/ml and 52.57±19.40 ng/ml, respectively). Six patients (40%) developed restenosis within 6 months. Mean stent length, mean stent diameter, and mean dilatation pressure were comparable in patient groups with and without restenosis. Levels of plasma VCAM-1 measured before and after PCI did not change significantly in patients without restenosis. However, these levels increased significantly in the group of restenosis. At 6 months, patients who developed restenosis, had higher VCAM-1 levels, as compared to baseline values (from 45.1±21.0 to 57.2±14.3 ng/ml, p=0.05). Plasma levels of pre and post PCI ICAM-1 did not differ significantly between groups with and without restenosis. These results suggest a more dominant role for VCAM-1, but not for ICAM-1 in development of restenosis following coronary stent implantation. |
---|---|
ISSN: | 2149-2263 2149-2271 |