Loading…
Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band
The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-α diagonal band (d3Πu−→a3∑g+ electronic transition; Q-branch with v=v′=2) to determine the temperature of hydrogen containing high-frequency electrodeless...
Saved in:
Published in: | International journal of spectroscopy 2010-01, Vol.2010 (2010), p.1-8 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63 |
---|---|
cites | cdi_FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63 |
container_end_page | 8 |
container_issue | 2010 |
container_start_page | 1 |
container_title | International journal of spectroscopy |
container_volume | 2010 |
creator | Gavare, Zanda Revalde, Gita Skudra, Atis |
description | The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-α diagonal band (d3Πu−→a3∑g+ electronic transition; Q-branch with v=v′=2) to determine the temperature of hydrogen containing high-frequency electrodeless lamps (HFEDLs). The values of the rotational temperatures have been obtained from the relative intensity distributions for hydrogen-helium and hydrogen-argon HFEDLs depending on the applied current. The results have been compared with the method of temperature derivation from Doppler profiles of He 667.8 nm and Ar 772.4 nm lines. The results of both methods are in good agreement, showing that the method of gas temperature determination from the intensity distribution in the hydrogen Fulcher-α (2-2)Q band can be used for the hydrogen containing HFEDLs. It was observed that the admixture of 10% hydrogen in the argon HFEDLs significantly reduces the gas temperature. |
doi_str_mv | 10.1155/2010/804506 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_855990377</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2286863441</sourcerecordid><originalsourceid>FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63</originalsourceid><addsrcrecordid>eNqFkU9LxDAUxIsoKOrJsxA8KtWk2fTPUXfVFVb0oOfymr6skTZZkxTpd_HDGq0InnyXeYcfMwyTJEeMnjMmxEVGGb0o6UzQfCvZY3lZpNVMFNu__6zaTQ69f6XxeJUVLNtLPh478D2QJ-w36CAMDskCA7peGwjaGmIVWY6ts2s0ZG5NAG20WZOlXr-kNw7fBjRyJNcdyuBsix16T1bQbzxpRnJnAhqvw0gW2genm-Hb8x7Bx6QeTfB_Au5t9Bk6cOQKTHuQ7CjoPB7-6H7yfHP9NF-mq4fbu_nlKgUueEgZ5RKgbArWYlMoLvNGCCli37KhSmaglATKkDc5NCzjQklW5kUmS55xxJzvJyeT78bZ2MeH-tUOzsTIuhSiqigvigidTZB01nuHqt443YMba0brrwHqrwHqaYBIn070izYtvOt_4OMJxoiggl94VlW8FPwTuBKSbA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>855990377</pqid></control><display><type>article</type><title>Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band</title><source>Wiley Online Library Open Access</source><source>Publicly Available Content Database</source><source>Free Full-Text Journals in Chemistry</source><creator>Gavare, Zanda ; Revalde, Gita ; Skudra, Atis</creator><contributor>Stehle, Chantal</contributor><creatorcontrib>Gavare, Zanda ; Revalde, Gita ; Skudra, Atis ; Stehle, Chantal</creatorcontrib><description>The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-α diagonal band (d3Πu−→a3∑g+ electronic transition; Q-branch with v=v′=2) to determine the temperature of hydrogen containing high-frequency electrodeless lamps (HFEDLs). The values of the rotational temperatures have been obtained from the relative intensity distributions for hydrogen-helium and hydrogen-argon HFEDLs depending on the applied current. The results have been compared with the method of temperature derivation from Doppler profiles of He 667.8 nm and Ar 772.4 nm lines. The results of both methods are in good agreement, showing that the method of gas temperature determination from the intensity distribution in the hydrogen Fulcher-α (2-2)Q band can be used for the hydrogen containing HFEDLs. It was observed that the admixture of 10% hydrogen in the argon HFEDLs significantly reduces the gas temperature.</description><identifier>ISSN: 1687-9449</identifier><identifier>EISSN: 1687-9457</identifier><identifier>DOI: 10.1155/2010/804506</identifier><language>eng</language><publisher>Cairo, Egypt: Hindawi Puplishing Corporation</publisher><subject>Helium ; Lamps ; Methods ; Plasma ; Studies</subject><ispartof>International journal of spectroscopy, 2010-01, Vol.2010 (2010), p.1-8</ispartof><rights>Copyright © 2010</rights><rights>Copyright © 2010 Zanda Gavare et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63</citedby><cites>FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/855990377/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/855990377?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>314,780,784,25753,27924,27925,37012,44590,75126</link.rule.ids></links><search><contributor>Stehle, Chantal</contributor><creatorcontrib>Gavare, Zanda</creatorcontrib><creatorcontrib>Revalde, Gita</creatorcontrib><creatorcontrib>Skudra, Atis</creatorcontrib><title>Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band</title><title>International journal of spectroscopy</title><description>The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-α diagonal band (d3Πu−→a3∑g+ electronic transition; Q-branch with v=v′=2) to determine the temperature of hydrogen containing high-frequency electrodeless lamps (HFEDLs). The values of the rotational temperatures have been obtained from the relative intensity distributions for hydrogen-helium and hydrogen-argon HFEDLs depending on the applied current. The results have been compared with the method of temperature derivation from Doppler profiles of He 667.8 nm and Ar 772.4 nm lines. The results of both methods are in good agreement, showing that the method of gas temperature determination from the intensity distribution in the hydrogen Fulcher-α (2-2)Q band can be used for the hydrogen containing HFEDLs. It was observed that the admixture of 10% hydrogen in the argon HFEDLs significantly reduces the gas temperature.</description><subject>Helium</subject><subject>Lamps</subject><subject>Methods</subject><subject>Plasma</subject><subject>Studies</subject><issn>1687-9449</issn><issn>1687-9457</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNqFkU9LxDAUxIsoKOrJsxA8KtWk2fTPUXfVFVb0oOfymr6skTZZkxTpd_HDGq0InnyXeYcfMwyTJEeMnjMmxEVGGb0o6UzQfCvZY3lZpNVMFNu__6zaTQ69f6XxeJUVLNtLPh478D2QJ-w36CAMDskCA7peGwjaGmIVWY6ts2s0ZG5NAG20WZOlXr-kNw7fBjRyJNcdyuBsix16T1bQbzxpRnJnAhqvw0gW2genm-Hb8x7Bx6QeTfB_Au5t9Bk6cOQKTHuQ7CjoPB7-6H7yfHP9NF-mq4fbu_nlKgUueEgZ5RKgbArWYlMoLvNGCCli37KhSmaglATKkDc5NCzjQklW5kUmS55xxJzvJyeT78bZ2MeH-tUOzsTIuhSiqigvigidTZB01nuHqt443YMba0brrwHqrwHqaYBIn070izYtvOt_4OMJxoiggl94VlW8FPwTuBKSbA</recordid><startdate>20100101</startdate><enddate>20100101</enddate><creator>Gavare, Zanda</creator><creator>Revalde, Gita</creator><creator>Skudra, Atis</creator><general>Hindawi Puplishing Corporation</general><general>Hindawi Publishing Corporation</general><general>Hindawi Limited</general><scope>ADJCN</scope><scope>AHFXO</scope><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7QH</scope><scope>7UA</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>BKSAR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>CWDGH</scope><scope>D1I</scope><scope>DWQXO</scope><scope>F1W</scope><scope>H97</scope><scope>HCIFZ</scope><scope>KB.</scope><scope>L.G</scope><scope>P5Z</scope><scope>P62</scope><scope>PCBAR</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope></search><sort><creationdate>20100101</creationdate><title>Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band</title><author>Gavare, Zanda ; Revalde, Gita ; Skudra, Atis</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Helium</topic><topic>Lamps</topic><topic>Methods</topic><topic>Plasma</topic><topic>Studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gavare, Zanda</creatorcontrib><creatorcontrib>Revalde, Gita</creatorcontrib><creatorcontrib>Skudra, Atis</creatorcontrib><collection>الدوريات العلمية والإحصائية - e-Marefa Academic and Statistical Periodicals</collection><collection>معرفة - المحتوى العربي الأكاديمي المتكامل - e-Marefa Academic Complete</collection><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access Journals</collection><collection>CrossRef</collection><collection>Aqualine</collection><collection>Water Resources Abstracts</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>Natural Science Collection</collection><collection>Earth, Atmospheric & Aquatic Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Middle East & Africa Database</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central Korea</collection><collection>ASFA: Aquatic Sciences and Fisheries Abstracts</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) 3: Aquatic Pollution & Environmental Quality</collection><collection>SciTech Premium Collection</collection><collection>Materials Science Database</collection><collection>Aquatic Science & Fisheries Abstracts (ASFA) Professional</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Earth, Atmospheric & Aquatic Science Database</collection><collection>Materials Science Collection</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><jtitle>International journal of spectroscopy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gavare, Zanda</au><au>Revalde, Gita</au><au>Skudra, Atis</au><au>Stehle, Chantal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band</atitle><jtitle>International journal of spectroscopy</jtitle><date>2010-01-01</date><risdate>2010</risdate><volume>2010</volume><issue>2010</issue><spage>1</spage><epage>8</epage><pages>1-8</pages><issn>1687-9449</issn><eissn>1687-9457</eissn><abstract>The goal of the present work was the investigation of the possibility to use intensity distribution of the Q-branch lines of the hydrogen Fulcher-α diagonal band (d3Πu−→a3∑g+ electronic transition; Q-branch with v=v′=2) to determine the temperature of hydrogen containing high-frequency electrodeless lamps (HFEDLs). The values of the rotational temperatures have been obtained from the relative intensity distributions for hydrogen-helium and hydrogen-argon HFEDLs depending on the applied current. The results have been compared with the method of temperature derivation from Doppler profiles of He 667.8 nm and Ar 772.4 nm lines. The results of both methods are in good agreement, showing that the method of gas temperature determination from the intensity distribution in the hydrogen Fulcher-α (2-2)Q band can be used for the hydrogen containing HFEDLs. It was observed that the admixture of 10% hydrogen in the argon HFEDLs significantly reduces the gas temperature.</abstract><cop>Cairo, Egypt</cop><pub>Hindawi Puplishing Corporation</pub><doi>10.1155/2010/804506</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1687-9449 |
ispartof | International journal of spectroscopy, 2010-01, Vol.2010 (2010), p.1-8 |
issn | 1687-9449 1687-9457 |
language | eng |
recordid | cdi_proquest_journals_855990377 |
source | Wiley Online Library Open Access; Publicly Available Content Database; Free Full-Text Journals in Chemistry |
subjects | Helium Lamps Methods Plasma Studies |
title | Plasma Temperature Determination of Hydrogen Containing High-Frequency Electrodeless Lamps by Intensity Distribution Measurements of Hydrogen Molecular Band |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T01%3A24%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Plasma%20Temperature%20Determination%20of%20Hydrogen%20Containing%20High-Frequency%20Electrodeless%20Lamps%20by%20Intensity%20Distribution%20Measurements%20of%20Hydrogen%20Molecular%20Band&rft.jtitle=International%20journal%20of%20spectroscopy&rft.au=Gavare,%20Zanda&rft.date=2010-01-01&rft.volume=2010&rft.issue=2010&rft.spage=1&rft.epage=8&rft.pages=1-8&rft.issn=1687-9449&rft.eissn=1687-9457&rft_id=info:doi/10.1155/2010/804506&rft_dat=%3Cproquest_cross%3E2286863441%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-a353t-103caa8b71deb7f3c6b55c54498b0fc2affca01e3b6ab1235fc18672c8323ee63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=855990377&rft_id=info:pmid/&rfr_iscdi=true |