This paper reports the incorporation of a Josephson waveform synthesizer (JWS) into the primary standard for AC electrical power at the Physikalisch-Technische Bundesanstalt (PTB). The increase to 10 V of the amplitude delivered by the JWS has allowed matching of the levels of the signals measured t...
Saved in:
Published in: | IEEE transactions on instrumentation and measurement 2009-04, Vol.58 (4), p.1049-1053 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper reports the incorporation of a Josephson waveform synthesizer (JWS) into the primary standard for AC electrical power at the Physikalisch-Technische Bundesanstalt (PTB). The increase to 10 V of the amplitude delivered by the JWS has allowed matching of the levels of the signals measured to determine the active, reactive, and apparent power-at the 120-V and 5-A level, which is also measured by the device under test. The inherent noise- and drift-free voltages delivered by the JWS allow calibration of the core sampling voltmeter of the PTB primary power standard with an uncertainty of 0.4 muV/V(k = 1) in 100 signal periods and as part of the measuring sequence. |
---|---|