Loading…

The Josephson-Effect-Based Primary AC Power Standard at the PTB: Progress Report

This paper reports the incorporation of a Josephson waveform synthesizer (JWS) into the primary standard for AC electrical power at the Physikalisch-Technische Bundesanstalt (PTB). The increase to 10 V of the amplitude delivered by the JWS has allowed matching of the levels of the signals measured t...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on instrumentation and measurement 2009-04, Vol.58 (4), p.1049-1053
Main Authors: Palafox, L., Behr, R., Ihlenfeld, W.G.K., Muller, F., Mohns, E., Seckelmann, M., Ahlers, F.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper reports the incorporation of a Josephson waveform synthesizer (JWS) into the primary standard for AC electrical power at the Physikalisch-Technische Bundesanstalt (PTB). The increase to 10 V of the amplitude delivered by the JWS has allowed matching of the levels of the signals measured to determine the active, reactive, and apparent power-at the 120-V and 5-A level, which is also measured by the device under test. The inherent noise- and drift-free voltages delivered by the JWS allow calibration of the core sampling voltmeter of the PTB primary power standard with an uncertainty of 0.4 muV/V(k = 1) in 100 signal periods and as part of the measuring sequence.
ISSN:0018-9456
1557-9662
DOI:10.1109/TIM.2008.2008862