Loading…
Red Cell Cytograms Generated by an ADVIA 120 Automated Hematology Analyzer: Characteristic Patterns in Common Hematological Conditions
Kakkar and Makkar present characteristic red cell cytograms generated by Advia-120, a 5-part automated hematology analyzer, as seen in common hematological conditions. Results show that common hematological conditions like iron deficiency anemia, thalassemia, macrocytic anemia, dual deficiency anemi...
Saved in:
Published in: | Laboratory medicine 2009-09, Vol.40 (9), p.549-555 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Kakkar and Makkar present characteristic red cell cytograms generated by Advia-120, a 5-part automated hematology analyzer, as seen in common hematological conditions. Results show that common hematological conditions like iron deficiency anemia, thalassemia, macrocytic anemia, dual deficiency anemia, cold agglutinins, and others were diagnosed based on characteristic red cell cytogram patterns, red cell indices, and relevant biochemical/other investigations. Therefore conclude that red cell cytogram patterns from automated analyzers provide clinically useful information that acts as an adjunct to the numerical parameters and at times is even diagnostic of some hematological conditions not otherwise suspected. |
---|---|
ISSN: | 0007-5027 1943-7730 |
DOI: | 10.1309/LM23R7FULSTUJSJD |