Reliability of Grip Strength Assessment with the Computerized Jamar Dynamometer

The purpose of our study was to determine the reliability of the model PC5030PT computerized Jamar dynamometer (J. A. Preston, Jackson, MI). A test-retest reliability study was conducted in which 33 normal subjects were tested three times over a 6-week period. Standard procedures for assessing grip...

Full description

Saved in:
Bibliographic Details
Published in:OTJR (Thorofare, N.J.) N.J.), 1994, Vol.14 (1), p.3-18
Main Authors: Niebuhr, Bruce R., Marion, Rodger, Fike, M. Laurita
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213
cites cdi_FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213
container_end_page 18
container_issue 1
container_start_page 3
container_title OTJR (Thorofare, N.J.)
container_volume 14
creator Niebuhr, Bruce R.
Marion, Rodger
Fike, M. Laurita
description The purpose of our study was to determine the reliability of the model PC5030PT computerized Jamar dynamometer (J. A. Preston, Jackson, MI). A test-retest reliability study was conducted in which 33 normal subjects were tested three times over a 6-week period. Standard procedures for assessing grip strength were followed. Both left and right hands were tested. We quantified three characteristics of the force curve: (a) the slope of the rise in force, (b) the maximal or peak force, and (c) the mean sustained force over the last 3 sec of a 5-sec contraction. Reliability was good with intraclass reliability coefficients ranging from .84 to .93. We conclude that the computerized Jamar will yield reliable measurement of grip strength if the instrument is calibrated properly and if standardized procedures for grip strength testing are followed.
doi_str_mv 10.1177/153944929401400101
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_907251229</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_153944929401400101</sage_id><sourcerecordid>2525154631</sourcerecordid><originalsourceid>FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMoWKt_wFPwvjaT7GY3x1K1KoWCH-cl3Z20Kd0PkxRZf70pFTwInubred8ZhpBrYLcAeT6BTKg0VVylDFLGgMEJGYESRcJFIU5jHoHkQJyTC--3EZFxMiLLF9xZvbI7GwbaGTp3tqevwWG7Dhs69R69b7AN9NPGOmyQzrqm3wd09gtr-qwb7ejd0OqmazB2L8mZ0TuPVz9xTN4f7t9mj8liOX-aTRdJJYCHBPSqQqGlTFldFCrXeZYVBjOopMqxlrVUsc-ESYt8xVOhwBjGai1YIRE4iDG5Ofr2rvvYow_lttu7Nq4sFct5BpyrCPEjVLnOe4em7J2NBw8lsPLwt_Lv36JochR5vcZf138U3-F-bLQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>907251229</pqid></control><display><type>article</type><title>Reliability of Grip Strength Assessment with the Computerized Jamar Dynamometer</title><source>Social Science Premium Collection</source><source>Education Collection</source><creator>Niebuhr, Bruce R. ; Marion, Rodger ; Fike, M. Laurita</creator><creatorcontrib>Niebuhr, Bruce R. ; Marion, Rodger ; Fike, M. Laurita</creatorcontrib><description>The purpose of our study was to determine the reliability of the model PC5030PT computerized Jamar dynamometer (J. A. Preston, Jackson, MI). A test-retest reliability study was conducted in which 33 normal subjects were tested three times over a 6-week period. Standard procedures for assessing grip strength were followed. Both left and right hands were tested. We quantified three characteristics of the force curve: (a) the slope of the rise in force, (b) the maximal or peak force, and (c) the mean sustained force over the last 3 sec of a 5-sec contraction. Reliability was good with intraclass reliability coefficients ranging from .84 to .93. We conclude that the computerized Jamar will yield reliable measurement of grip strength if the instrument is calibrated properly and if standardized procedures for grip strength testing are followed.</description><identifier>ISSN: 1539-4492</identifier><identifier>EISSN: 1938-2383</identifier><identifier>DOI: 10.1177/153944929401400101</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Computers ; Occupational Therapy ; Reliability ; Resistance (Psychology) ; Validity</subject><ispartof>OTJR (Thorofare, N.J.), 1994, Vol.14 (1), p.3-18</ispartof><rights>1994 American Occupational Therapy Foundation</rights><rights>Copyright SLACK INCORPORATED Winter 1994</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213</citedby><cites>FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/907251229/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$H</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/907251229?pq-origsite=primo$$EHTML$$P50$$Gproquest$$H</linktohtml><link.rule.ids>314,780,784,4024,21378,21394,27923,27924,27925,33611,33877,43733,43880,74221,74397</link.rule.ids></links><search><creatorcontrib>Niebuhr, Bruce R.</creatorcontrib><creatorcontrib>Marion, Rodger</creatorcontrib><creatorcontrib>Fike, M. Laurita</creatorcontrib><title>Reliability of Grip Strength Assessment with the Computerized Jamar Dynamometer</title><title>OTJR (Thorofare, N.J.)</title><description>The purpose of our study was to determine the reliability of the model PC5030PT computerized Jamar dynamometer (J. A. Preston, Jackson, MI). A test-retest reliability study was conducted in which 33 normal subjects were tested three times over a 6-week period. Standard procedures for assessing grip strength were followed. Both left and right hands were tested. We quantified three characteristics of the force curve: (a) the slope of the rise in force, (b) the maximal or peak force, and (c) the mean sustained force over the last 3 sec of a 5-sec contraction. Reliability was good with intraclass reliability coefficients ranging from .84 to .93. We conclude that the computerized Jamar will yield reliable measurement of grip strength if the instrument is calibrated properly and if standardized procedures for grip strength testing are followed.</description><subject>Computers</subject><subject>Occupational Therapy</subject><subject>Reliability</subject><subject>Resistance (Psychology)</subject><subject>Validity</subject><issn>1539-4492</issn><issn>1938-2383</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1994</creationdate><recordtype>article</recordtype><sourceid>ALSLI</sourceid><sourceid>CJNVE</sourceid><sourceid>M0P</sourceid><recordid>eNp9kE1LAzEQhoMoWKt_wFPwvjaT7GY3x1K1KoWCH-cl3Z20Kd0PkxRZf70pFTwInubred8ZhpBrYLcAeT6BTKg0VVylDFLGgMEJGYESRcJFIU5jHoHkQJyTC--3EZFxMiLLF9xZvbI7GwbaGTp3tqevwWG7Dhs69R69b7AN9NPGOmyQzrqm3wd09gtr-qwb7ejd0OqmazB2L8mZ0TuPVz9xTN4f7t9mj8liOX-aTRdJJYCHBPSqQqGlTFldFCrXeZYVBjOopMqxlrVUsc-ESYt8xVOhwBjGai1YIRE4iDG5Ofr2rvvYow_lttu7Nq4sFct5BpyrCPEjVLnOe4em7J2NBw8lsPLwt_Lv36JochR5vcZf138U3-F-bLQ</recordid><startdate>1994</startdate><enddate>1994</enddate><creator>Niebuhr, Bruce R.</creator><creator>Marion, Rodger</creator><creator>Fike, M. Laurita</creator><general>SAGE Publications</general><general>SAGE PUBLICATIONS, INC</general><scope>AAYXX</scope><scope>CITATION</scope><scope>0-V</scope><scope>3V.</scope><scope>7RV</scope><scope>7T2</scope><scope>7X7</scope><scope>7XB</scope><scope>88B</scope><scope>88C</scope><scope>88E</scope><scope>88G</scope><scope>88I</scope><scope>8AF</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ALSLI</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>C1K</scope><scope>CCPQU</scope><scope>CJNVE</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>KB0</scope><scope>M0P</scope><scope>M0S</scope><scope>M0T</scope><scope>M1P</scope><scope>M2M</scope><scope>M2P</scope><scope>NAPCQ</scope><scope>PQEDU</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PSYQQ</scope><scope>Q9U</scope><scope>S0X</scope></search><sort><creationdate>1994</creationdate><title>Reliability of Grip Strength Assessment with the Computerized Jamar Dynamometer</title><author>Niebuhr, Bruce R. ; Marion, Rodger ; Fike, M. Laurita</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Computers</topic><topic>Occupational Therapy</topic><topic>Reliability</topic><topic>Resistance (Psychology)</topic><topic>Validity</topic><toplevel>online_resources</toplevel><creatorcontrib>Niebuhr, Bruce R.</creatorcontrib><creatorcontrib>Marion, Rodger</creatorcontrib><creatorcontrib>Fike, M. Laurita</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Social Sciences Premium Collection</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>Health and Safety Science Abstracts (Full archive)</collection><collection>ProQuest Health and Medical</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Education Database (Alumni Edition)</collection><collection>Healthcare Administration Database (Alumni)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Psychology Database (Alumni)</collection><collection>Science Database (Alumni Edition)</collection><collection>STEM Database</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Social Science Premium Collection</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Education Collection</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>ProQuest Education Journals</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>ProQuest Healthcare Administration Database</collection><collection>Medical Database</collection><collection>Psychology Database (ProQuest)</collection><collection>ProQuest Science Journals</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest One Education</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest One Psychology</collection><collection>ProQuest Central Basic</collection><collection>SIRS Editorial</collection><jtitle>OTJR (Thorofare, N.J.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Niebuhr, Bruce R.</au><au>Marion, Rodger</au><au>Fike, M. Laurita</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Reliability of Grip Strength Assessment with the Computerized Jamar Dynamometer</atitle><jtitle>OTJR (Thorofare, N.J.)</jtitle><date>1994</date><risdate>1994</risdate><volume>14</volume><issue>1</issue><spage>3</spage><epage>18</epage><pages>3-18</pages><issn>1539-4492</issn><eissn>1938-2383</eissn><abstract>The purpose of our study was to determine the reliability of the model PC5030PT computerized Jamar dynamometer (J. A. Preston, Jackson, MI). A test-retest reliability study was conducted in which 33 normal subjects were tested three times over a 6-week period. Standard procedures for assessing grip strength were followed. Both left and right hands were tested. We quantified three characteristics of the force curve: (a) the slope of the rise in force, (b) the maximal or peak force, and (c) the mean sustained force over the last 3 sec of a 5-sec contraction. Reliability was good with intraclass reliability coefficients ranging from .84 to .93. We conclude that the computerized Jamar will yield reliable measurement of grip strength if the instrument is calibrated properly and if standardized procedures for grip strength testing are followed.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><doi>10.1177/153944929401400101</doi><tpages>16</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1539-4492
ispartof OTJR (Thorofare, N.J.), 1994, Vol.14 (1), p.3-18
issn 1539-4492
1938-2383
language eng
recordid cdi_proquest_journals_907251229
source Social Science Premium Collection; Education Collection
subjects Computers
Occupational Therapy
Reliability
Resistance (Psychology)
Validity
title Reliability of Grip Strength Assessment with the Computerized Jamar Dynamometer
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T20%3A05%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Reliability%20of%20Grip%20Strength%20Assessment%20with%20the%20Computerized%20Jamar%20Dynamometer&rft.jtitle=OTJR%20(Thorofare,%20N.J.)&rft.au=Niebuhr,%20Bruce%20R.&rft.date=1994&rft.volume=14&rft.issue=1&rft.spage=3&rft.epage=18&rft.pages=3-18&rft.issn=1539-4492&rft.eissn=1938-2383&rft_id=info:doi/10.1177/153944929401400101&rft_dat=%3Cproquest_cross%3E2525154631%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c312t-1abce3a6640d8897a7558fe51c697ed6d69d8803f487b24391ff00da3086e1213%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=907251229&rft_id=info:pmid/&rft_sage_id=10.1177_153944929401400101&rfr_iscdi=true