Loading…

Reliability and Repeatability of the Hoffmann Sign

Objective To determine the inter-rater, intrarater, and intrasubject reliability of the Hoffmann sign. Design Observational, cross-sectional study. Setting Veterans Affairs medical center. Patients Fifty-two consenting subjects without amputation of the first through third fingers, fixed finger cont...

Full description

Saved in:
Bibliographic Details
Published in:PM & R 2012-07, Vol.4 (7), p.498-503
Main Authors: Annaswamy, Thiru M., MD, MA, Sakai, Tomoya, MD, Goetz, Lance L., MD, Pacheco, Fides M., MD, Ozarkar, Tejas, BBA
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective To determine the inter-rater, intrarater, and intrasubject reliability of the Hoffmann sign. Design Observational, cross-sectional study. Setting Veterans Affairs medical center. Patients Fifty-two consenting subjects without amputation of the first through third fingers, fixed finger contractures, relapsing remitting multiple sclerosis, or any acute central neurological illness or injury within the past 3 months requiring hospital admission were recruited from inpatients and outpatients in the Spinal Cord Injury and Physical Medicine and Rehabilitation services. Interventions The Hoffmann sign was elicited by 1 primary and 3 secondary investigators who used a standardized technique. The Hoffmann sign was considered positive if any reflexive flexion of the distal phalanx of the thumb or any of the fingers was present. In the first session, the primary and one secondary examiner performed 2 trials on both hands of each subject. Each investigator pair repeated the procedure in a second session. Main Outcome Measures Cohen's κ coefficient was calculated to determine (1) inter-rater reliability, calculated per investigator pair per hand, for the first trial of a session; (2) intrarater reliability, calculated between the 2 trials of each session per investigator; and (3) intrasubject reliability, calculated per hand of each subject between the first trials of the 2 sessions. Results Inter-rater κ was 0.65 (188 pairs), intrarater κ was 0.89 (384 pairs), and intrasubject κ was 0.73 (178 pairs). All κ values were obtained with P < .01. Conclusions The Hoffmann sign has substantial inter-rater and intrasubject reliability, in addition to outstanding intrarater reliability, when tested with the use of a standardized technique.
ISSN:1934-1482
1934-1563
DOI:10.1016/j.pmrj.2012.02.019